ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
111
|
Mon Apr 17 19:19:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_HPK_CB_100V.dat | 006 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 610. Bias scan 100 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_006_HPK_CB_100V.dat |
Telescope run |
610 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
94
|
Mon Apr 17 09:04:02 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_Baby_100V.dat | 006 | k.a. | 102.5, 22.5, 230 | No | Unknown |
Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).
Forgot ro record data in elog.
Parameter |
Value |
Alibava run |
run_006_Baby_100V.dat |
Telescope run |
570 |
Triggers |
k.a. |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
131
|
Wed Apr 19 22:56:07 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_Irrad_450V.dat | 005 | 2800000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 635. Bias scan -450V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing! Run crashed over night. Triggers valid up to 2032867.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_005_Irrad_450V.dat |
Telescope run |
635 |
Triggers |
2800000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-450 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
38.8 uA |
|
8
|
Thu Apr 13 09:23:20 2017 |
Axel König | ALiBaVa (IFX) | run_005_IFX_CB_10V.dat | 005 | 285000 | 109, 4.5, 240 | No | Unknown |
Remarks: Telescope run 508. Bias scan 10 V.
Parameter |
Value |
Alibava run |
run_005_IFX_CB_10V.dat |
Telescope run |
508 |
Triggers |
285000 |
Alibava trigger eff. |
~36.5% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-10 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
109
|
Mon Apr 17 17:46:38 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_HPK_CB_50V.dat | 005 | 150000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 609. Bias scan 50 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_HPK_CB_50V.dat |
Telescope run |
609 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-50 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
80
|
Sat Apr 15 20:12:41 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_Baby_100V.dat | 005 | 250000 | 102.5, 22.5, 230 | No | Unknown |
Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_Baby_100V.dat |
Telescope run |
568 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
130
|
Wed Apr 19 22:01:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_Irrad_400V.dat | 004 | 250000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 633. Bias scan -400V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_004_Irrad_400V.dat |
Telescope run |
633 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-400 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
37.5 uA |
|
118
|
Tue Apr 18 08:04:39 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_HPK_CB_200V.dat | 004 | 250000 | 107, 2.6, 250 | No | Unknown |
Remarks: Telescope run 607. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_HPK_CB_200V.dat |
Telescope run |
607 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
250 deg
|
|
79
|
Sat Apr 15 19:20:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_Baby_100V.dat | 004 | 250000 | 102.5, 22.5, 250 | No | Unknown |
Remarks: Telescope run 565. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_Baby_100V.dat |
Telescope run |
565 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
250 deg
|
|
125
|
Tue Apr 18 21:03:42 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_double_irrad_100V.dat | 003 | 3500000 | 103, 1, 240 | No | Unknown |
Remarks: Telescope run 625. Both chips. Central position. Run crashed over night.
Collected triggers 2710991.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_003_double_irrad_100V.dat |
Telescope run |
625 |
Triggers |
3500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
103 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
129
|
Wed Apr 19 20:55:36 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_Irrad_300V.dat | 003 | 300000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 632. Bias scan -300V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_003_Irrad_300V.dat |
Telescope run |
632 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-300 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
35.1 uA |
|
5
|
Wed Apr 12 22:41:08 2017 |
Axel König | ALiBaVa (IFX) | run_003_IFX_CB_100V.dat | 003 | 100000 | 109, 8.5, 240 | No | Unknown |
Remarks: Beam position on only one chip.
Parameter |
Value |
Alibava run |
run_003_IFX_CB_100V.dat |
Telescope run |
500 |
Triggers |
100000 |
Alibava trigger eff |
? |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 V |
Latency |
132 |
Table x |
109 mm |
table z |
8.5 mm |
table rot |
240 deg (parallel to tele. planes) |
|
107
|
Mon Apr 17 17:02:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_HPK_CB_200V.dat | 003 | 250000 | 107, 2.6, 230 | No | Unknown |
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
78
|
Sat Apr 15 18:31:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_Baby_100V.dat | 003 | 250000 | 102.5, 32.5, 240 | No | Unknown |
Remarks: Telescope run 564. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_Baby_100V.dat |
Telescope run |
564 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
32.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
124
|
Tue Apr 18 18:48:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_double_irrad_100V.dat | 002 | 700000 | 94, 1, 240 | No | Unknown |
Remarks: Telescope run 623. 1nd chip only. Central position.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_002_double_irrad_100V.dat |
Telescope run |
623 |
Triggers |
700000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
94 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
128
|
Wed Apr 19 19:27:38 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_Irrad_200V.dat | 002 | 400000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 630. Bias scan -200V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_002_Irrad_200V.dat |
Telescope run |
630 |
Triggers |
400000 |
Alibava trigger eff. |
~65% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
29.7 uA |
|
4
|
Wed Apr 12 22:34:18 2017 |
Axel König | ALiBaVa (IFX) | run_002_IFX_CB_100V.dat | 002 | 100000 | 109, 0.5, 240 | No | Unknown |
Remarks: Beam position on only one chip.
Parameter |
Value |
Alibava run |
run_002_IFX_CB_100V.dat |
Telescope run |
498 |
triggers |
100000 |
Alibava trigger eff. |
? |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 V |
Latency |
132 |
Table x |
109 mm |
Table z |
0.5 mm |
Table rot |
240 deg (parallel to tele. planes) |
|
106
|
Mon Apr 17 16:36:56 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_HPK_CB_200V.dat | 002 | 450000 | 107, 5.8, 240 | No | Unknown |
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
77
|
Sat Apr 15 17:38:58 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_Baby_100V.dat | 002 | 250000 | 102.5, 12.5, 240 | No | Unknown |
Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_Baby_100V.dat |
Telescope run |
563 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
12.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
123
|
Tue Apr 18 18:19:33 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_double_irrad_100V.dat | 001 | 350000 | 111, 1, 240 | No | Unknown |
Remarks: Telescope run 620. 2nd chip only. Central position.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_001_double_irrad_100V.dat |
Telescope run |
620 |
Triggers |
350000 |
Alibava trigger eff. |
~53% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
111 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|