  HEPHY logbook of the Electronics Group, Page 2 of 4  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Project Measurement Type Object ID Subject Text Attachments
  46   Fri May 22 12:01:32 2015 Hao Yin   CMC injection LV 10VComparison w/o filter (LC) connected to
-z_n side.

Mateo has the results.
  
  45   Thu May 21 18:23:22 2015 Hao Yin   Noise Injection LV cable(TestNr. 15)

injecting sin wave into LV at different
 P1000717.JPG 
  44   Wed May 20 10:12:12 2015 Hao Yin   Ladder RLC test (CMC Injection)L5 Ladder Test

folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test

Setup: ladder
  
  43   Tue May 19 14:48:06 2015 Hao YinBelle IImoduleL6 Noise inJection RunsL6 Noise inJection RunsFolder "L6_RLC_Test"

Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg

3 Tests: Injkection to 2.5V 1.25V.
  
  42   Tue May 19 13:42:04 2015 Hao Yin   L6 Noise inJection SetupTest Nr. 1:

RLC between DockBox and Hybrid
(both side).
 P1000702.JPGP1000700.JPGP1000699.JPGP1000703.JPGP1000707.JPG 
  41   Tue May 19 13:23:16 2015 Hao YinBelle IIsystemCalibrationCalibrationRun001PedestalRun001, FIRRun001,

room temperature,

no noise injection
  
  40   Tue May 19 11:01:29 2015 Hao YinBelle IIsystemPedestalPedestalRunFIRRun001

Baseline measurement without injections,
50000 event,
 16x 
  39   Tue May 19 10:57:19 2015 Hao YinBelle IIsystemFIRFIR filterfirst fir filter run:

# 1:[0x[FADC ID] in hex], 2:[APV25
ChannelNr], 3-10:[fir coef in float]
  
  38   Tue May 19 10:08:53 2015 Hao Yin   FADC system setup success3 FADC. All Channel/APV25 running (except
L3 n first and last -> not connected (bonding))

n-side: all connectors
  
  37   Tue May 19 09:31:50 2015 Hao Yin   Noise Test ITAEverything works except L3 p-side.

The config file is shown in the
following:
  
  36   Thu Jun 5 10:34:45 2014 Benedikt WürknerBelle IIsourceSilc ModuleSilc Angle Measurement 10°Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. 
  
  35   Thu Jun 5 10:34:29 2014 Benedikt WürknerBelle IIsourceSilc ModuleSilc Angle Measurement 7°Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. 
  
  34   Thu Jun 5 10:34:06 2014 Benedikt WürknerBelle IIsourceSilc ModuleSilc Angle Measurement 4°Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. 
  
  33   Thu Jun 5 10:33:46 2014 Benedikt WürknerBelle IIsourceSilc ModuleSilc Angle Measurement 1°Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. 
  
  32   Fri May 16 11:40:29 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 6 of 6 room temperature measurements using Sr90 Source (single)Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
 10x 
  31   Fri May 16 11:38:44 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 5 of 6 room temperature measurements using Sr90 Source (single)Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
 10x 
  30   Fri May 16 11:37:05 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 4 of 6 room temperature measurements using Sr90 Source (single)Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
 10x 
  29   Fri May 9 16:44:41 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 3 of 6 room temperature measurements using Sr90 Source (single)Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
 10x 
  28   Fri May 9 15:12:44 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 2 of 6 room temperature measurements using Sr90 Source (single)Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
 10x 
  27   Thu May 8 16:51:57 2014 Benedikt WürknerBelle IIsourceL3 moduleNo 2 of 6 room temperature measurements using Sr90 Source (single)Failed with Error: "***ERROR*** Init
NECO failed,  Return code: -32761"
Restarted and it works again
  