Fri May 22 12:01:32 2015, Hao Yin, , , , CMC injection LV 10V
|
Comparison w/o filter (LC) connected to -z_n side.
Mateo has the results. |
Thu May 21 18:23:22 2015, Hao Yin, , , , Noise Injection LV cable
|
(TestNr. 15)
injecting sin wave into LV at different frequencies to analyse the output frequency and noise ground level after the junction borad. |
Wed May 20 10:12:12 2015, Hao Yin, , , , Ladder RLC test (CMC Injection)
|
L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder only, noise injection on one hybrid (injection point = cable between hybrid and junction board, see attachment |
Tue May 19 14:48:06 2015, Hao Yin, Belle II, module, L6 Noise inJection Runs, L6 Noise inJection Runs
|
Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V. ground and their combination |
Tue May 19 13:42:04 2015, Hao Yin, , , , L6 Noise inJection Setup
|
Test Nr. 1:
RLC between DockBox and Hybrid (both side).
Preliminary Test on L6, but all other sensors are connected. |
Tue May 19 13:23:16 2015, Hao Yin, Belle II, system, Calibration, CalibrationRun001
|
PedestalRun001, FIRRun001,
room temperature,
no noise injection |
Tue May 19 11:01:29 2015, Hao Yin, Belle II, system, Pedestal, PedestalRun 16x
|
FIRRun001
Baseline measurement without injections, 50000 event,
room temperature. |
Tue May 19 10:57:19 2015, Hao Yin, Belle II, system, FIR, FIR filter
|
first fir filter run:
# 1:[0x[FADC ID] in hex], 2:[APV25 ChannelNr], 3-10:[fir coef in float]
0x1,0,1.13520608876,-0.0660414994664,-0.0344046528212,-0.0160940592489,-0.0188049576486,-0.00405635272718,0.0022422085805,0.0019532245698 |
Tue May 19 10:08:53 2015, Hao Yin, , , , FADC system setup success
|
3 FADC. All Channel/APV25 running (except L3 n first and last -> not connected (bonding))
n-side: all connectors
p-side: 0x01: 1, 2, 4 and 0x02, 1 with L3 p and L4 p (Telescope) |
Tue May 19 09:31:50 2015, Hao Yin, , , , Noise Test ITA
|
Everything works except L3 p-side.
The config file is shown in the following:
### Original Configuration File Name: /home/katsuro/tuxdaq_devel/config/delay_scan.latency_scan.cfg ### |
Thu Jun 5 10:34:45 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 10°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Thu Jun 5 10:34:29 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 7°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Thu Jun 5 10:34:06 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 4°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Thu Jun 5 10:33:46 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 1°
|
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles.
Data can be found on heros in: /home/medialib/LAB_Silc_Angle.
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. |
Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right) |
Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center) |
Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left) |
Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center) |
Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center) |
Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single)
|
Failed with Error: "***ERROR*** Init NECO failed, Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source |
|