Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
electronics
module assembly
SiDDaTA
scratch
HEPHY logbook of the Electronics Group, Page 1 of 4
Not logged in
Find
|
Select
|
Login
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Common
Measurement
-- Project --
SPS Testbeam June08
Belle II
PixelFED
-- Measurement Type --
hybrid
module
source
system
64 Entries
Goto page 1,
2
,
3
,
4
Next
All
Selected entries:
Tracker Sensor QC
HGC Sensor QC
Process QC
Longterm
Visual Inspection
Process QC OLD
SQC
PQC
P3
HGC
Klimakammer
microscopes
infrastructure
test
cleanroom
lasersetup
module assembly
testbeam-MA2023
testbeam-MA2021
testbeam-MA2020
testbeam-MA2019
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
SiDDaTA
scratch
testbeam-MA2018
testbeam-MA2024
ID
Date
Author
Project
Measurement Type
Object ID
Subject
Text
37
Tue May 19 09:31:50 2015
Hao Yin
Noise Test ITA
Everything works except L3 p-side.
The config file is shown in the
following:
38
Tue May 19 10:08:53 2015
Hao Yin
FADC system setup success
3 FADC. All Channel/APV25 running (except
L3 n first and last -> not connected (bonding))
n-side: all connectors
42
Tue May 19 13:42:04 2015
Hao Yin
L6 Noise inJection Setup
Test Nr. 1:
RLC between DockBox and Hybrid
(both side).
44
Wed May 20 10:12:12 2015
Hao Yin
Ladder RLC test (CMC Injection)
L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder
45
Thu May 21 18:23:22 2015
Hao Yin
Noise Injection LV cable
(TestNr. 15)
injecting sin wave into LV at different
46
Fri May 22 12:01:32 2015
Hao Yin
CMC injection LV 10V
Comparison w/o filter (LC) connected to
-z_n side.
Mateo has the results.
51
Mon Nov 30 15:12:19 2015
Hao Yin
FIR_ADC config
FIR filter and ADC delay test:
ADC delay and FIR filter with and
without cooling to reproduce error detected
5
Wed Apr 30 16:52:17 2008
Markus Friedl
BELLE Upgrade
module
micron
micron sensor glued to frame
soeben haben wir den micron-DSSD (double metal
layer) in den 2-teiligen rahmen geklebt und
auf beiden seiten
14
Tue May 20 14:27:50 2008
Markus Friedl
BELLE Upgrade
source
micron
analysis results of source test
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED
THAT BIASING WAS NOT DONE PROPERLY
9x
15
Wed Oct 7 14:23:35 2009
Dieter Uhl
BELLE Upgrade
hybrid
#4
hybrid-pitchadapter
opens at upper coat
16
Wed Oct 7 14:24:06 2009
Dieter Uhl
BELLE Upgrade
hybrid
#5
hybrid-pitchadapter
shorts at upper coat
17
Sun Jul 4 05:48:36 2010
Christian Irmler
BELLE Upgrade
source
Origami 6 - module 1
run002: first analysis results
Run name: run002
Run type: 0 (Hardware (Normal Run))
7x
18
Wed May 7 14:36:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left)
10x
19
Wed May 7 15:04:32 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center)
10x
20
Wed May 7 15:53:38 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right)
10x
21
Wed May 7 16:43:37 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
10x
22
Wed May 7 17:33:21 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
10x
23
Wed May 7 18:20:36 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (multi6)
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
10x
26
Thu May 8 16:51:03 2014
Benedikt Würkner
Belle II
source
L3 module
No 1 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
10x
27
Thu May 8 16:51:57 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Failed with Error: "***ERROR*** Init
NECO failed, Return code: -32761"
Restarted and it works again
Goto page 1,
2
,
3
,
4
Next
All