Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Belle testbeam at SPS in June 2015, Page 5 of 6
Not logged in
Find
|
Login
|
Help
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Project --
common
Belle II FADC \(H6A)
SVD3 \(H6B)
-- Data --
Unknown
Good
Crap
107 Entries
Goto page
Previous
1
,
2
,
3
,
4
, 5,
6
Next
All
ID
Date
Author
Project
Subject
Run Number
Events
XYPosition
Cooling
Data
Text
39
Sun Jun 7 20:02:40 2015
Hao Yin
Belle II FADC (H6A)
Cooling Box Emergency break
Unknown
Something triggered a emergency break.
HWRun012 only last 1-10k event has to be
discarded.
50
Mon Jun 8 11:33:24 2015
Thomas Bergauer
common
beam profile
Unknown
120GeV hadrons, beam config H6A.BELLE.003
56
Mon Jun 8 16:53:13 2015
Benedikt Würkner
SVD3 (H6B)
EUTelescope Fitter not working investigation
Unknown
Apparently every problem can be attributed
to a misalignment problem. The telescope
has troubles with heavily misaligned DUTs.
58
Mon Jun 8 18:08:49 2015
Thomas Bergauer
SVD3 (H6B)
Telescope online monitor
Unknown
a working version of the EUDET online monitor
(which works also with the FE-I4) is at the
following location
59
Mon Jun 8 20:13:59 2015
Hao Yin
Belle II FADC (H6A)
Hardware
017
5
Yes
Good
cooled (see attachment) in -21.24 out -18.54
cooling supply emty at ~24:00 ie
first 30k is cooled.
63
Tue Jun 9 09:33:33 2015
Hao Yin
Belle II FADC (H6A)
Calibration
003
Good
room temp
FIRRun002,
pedestalrun006;
66
Tue Jun 9 10:01:03 2015
Lukas Bulla
SVD3 (H6B)
TLU setup info
Unknown
Channels:
Upstream vertical ->
channel 0; (bitmask 1)
Upstream
70
Tue Jun 9 16:22:59 2015
Benedikt Würkner
SVD3 (H6B)
Beam Profile Results
66 und 67
2
No
Good
72
Tue Jun 9 20:30:37 2015
Hao Yin
Belle II FADC (H6A)
FIR
004
Good
FIR filer and ADC delay with all sensor
and telescope.
Telescope alignment
75
Wed Jun 10 10:40:24 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
004
No
Good
room
temp
pedestalrun 008
76
Wed Jun 10 11:19:33 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
005
No
Good
room
temp
pedestalrun 008
77
Wed Jun 10 12:03:53 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
006
No
Good
room
temp
pedestalrun 008
78
Wed Jun 10 12:04:27 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
007
No
Good
room
temp
pedestalrun 008
79
Wed Jun 10 13:12:33 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
010
Yes
Good
cooled
pedestalrun 008
FIRRun004
80
Wed Jun 10 18:05:03 2015
Benedikt Würkner
SVD3 (H6B)
FEI4 configuration
No
Unknown
There are two planes, one fixed upstream
and one fixed downstream.
CIS3WII_6 upstream and CIS2WI_IBL2
83
Wed Jun 10 19:07:42 2015
Hao Yin
Belle II FADC (H6A)
Hardware
021
5
Yes
Good
temp:
in -23 out -20
FIRRun002,
84
Wed Jun 10 20:54:36 2015
Benedikt Würkner
SVD3 (H6B)
Residuals FE-I4 (Upstream)
59
10
No
Good
86
Thu Jun 11 11:41:50 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
011
Yes
Good
cooled
pedestalrun 008
FIRRun004
87
Thu Jun 11 11:42:39 2015
Hao Yin
Belle II FADC (H6A)
Sixlet Calibration
012
Yes
Good
cooled
until about 400k after that room temp
pedestalrun 009
89
Thu Jun 11 16:35:14 2015
Hao Yin
Belle II FADC (H6A)
Hardware
022
5
Yes
Good
temp:
in -23 out -20
FIRRun002,
Goto page
Previous
1
,
2
,
3
,
4
, 5,
6
Next
All
ELOG V3.1.5-fc6679b