Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle testbeam at SPS in June 2015, Page 5 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Sun Jun 7 10:36:38 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 006, 10000, , , Unknown Pos1.PNG
Cooled, Temp see attachment
FirRun002
 
Entry  Sun Jun 7 00:58:33 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw006, , , , Crap 
Table: 100:70

Bias: +-50V

600 pedestal
Entry  Sat Jun 6 23:30:29 2015, Benedikt Würkner, Belle II FADC (H6A), Hardware, 009, , , , Good 
room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 9 (p-0, n-128*4)
Entry  Sat Jun 6 21:00:15 2015, Benedikt Würkner, SVD3 (H6B), first hardware run with TLU and Telescope, hw004, 117171, , , Unknown 
Table: 100:70

Bias: +-50V

600 pedestal
Entry  Sat Jun 6 16:48:41 2015, Hao Yin, Belle II FADC (H6A), Hardware, 008, 50000, 8, No, Good 20x
room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 8 (p-0, n-0)
Entry  Sat Jun 6 16:18:48 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw003, 50000, , , Unknown 
Table: 100:70

Bias: +-50V

Run to confirm trigger delay
Entry  Sat Jun 6 16:17:52 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw002, 5000, , , Good 
Table: 100:70

Bias: +-50V

Run to confirm trigger delay
Entry  Sat Jun 6 16:14:36 2015, Benedikt Würkner, SVD3 (H6B), calibration run and setup information, cal01, , , , Unknown 
Calibration Run with +- 50V Bias with higher compliance since the p-side draws more current than expected (23muA by the MAMBO)

 
Entry  Sat Jun 6 14:28:28 2015, Hao Yin, Belle II FADC (H6A), Harware, 007, 50000, 7, No, Good 20x
room temp, FIRRun002, PedestalRun005, room temp

target: CE, pos 7 (p-0, n-0)
Entry  Sat Jun 6 12:43:55 2015, Hao Yin, Belle II FADC (H6A), Hardware, 006, 50000, 6, No, Good 20x
FIRRun002, room temp, pedestalrun005,
layout: same as HW 005
target: -z, pos 6 (strip: p-0, n-0);
Entry  Fri Jun 5 23:39:49 2015, Hao Yin, Belle II FADC (H6A), Hardware, 005, ~200k, 5, No, Good 21x
FIRRun002, pedestalrun005, room temp
Target BW: beam spot at ~ (0 p, 0 n)
Entry  Fri Jun 5 23:38:51 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 005, 10000, , , Unknown 
Readjust after cooling box.

room temp, firrun002
 
Entry  Fri Jun 5 19:59:44 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 004, 10000, , , Good 
update pedestal values for room temp sixlet runs.
 
Entry  Fri Jun 5 19:55:00 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 003, , , , Unknown 
lat = 98

room temp

pedestalrun 003
Entry  Fri Jun 5 12:03:34 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 002, , , , Good 
lat = 97 to a greater range of lat scan
Entry  Fri Jun 5 12:02:29 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 001, , , , Good 
room temp max subevent at 2. with lat = 96
Entry  Fri Jun 5 08:20:27 2015, Hao Yin, Belle II FADC (H6A), Hardware, 004, 50000, 4, No, Good 16x
room temp, FIRRun002, pedestalrun003, taget FW
Entry  Thu Jun 4 22:07:16 2015, Hao Yin, Belle II FADC (H6A), Hardware, 003, 189k, 3, No, Good 21x
CE. pedestal run 003. Fir run 002. Room temp
Entry  Thu Jun 4 18:49:03 2015, Benedikt Würkner, SVD3 (H6B), Setup, , , , , Unknown IMG_20150604_184442.jpgIMG_20150604_184451.jpgIMG_20150604_184516.jpg
 
Entry  Thu Jun 4 18:45:42 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 003, 10000, , , Good 
firrun003, room temp
 
ELOG V3.1.5-fc6679b