ID Date Author Project Subject Run Number Events XYPositiondown Cooling Data
  43   Sun Jun 7 23:04:06 2015 Hao YinBelle II FADC (H6A)Hardware01350000  Good

cooled (see attachment)

FIRRun002, PedestalRun006

target: CE, pos 3

cooling box emergency break ... ie about the last 1-10 k not useable.

  44   Sun Jun 7 23:09:29 2015 Hao YinBelle II FADC (H6A)Hardware014224k  Good

cooled (see attachment) in - 20,5 out -7,8

FIRRun002, PedestalRun006

target: fw, pos 4

  50   Mon Jun 8 11:33:24 2015 Thomas Bergauercommonbeam profile    Unknown

120GeV hadrons, beam config H6A.BELLE.003

  53   Mon Jun 8 15:03:53 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and FEI4 WORKING5919000  Unknown

Testrun with the FEI4 working for the first time. 

Lessons learned about the configuration:

EnableDUTVeto needs to be set for the FEI4 to allow it to work

HandShakeMode needs to be enabled for the FEI4 as well

"Enable RJ45 input during scans" needs to be enabled for the USB-controller

  56   Mon Jun 8 16:53:13 2015 Benedikt WürknerSVD3 (H6B)EUTelescope Fitter not working investigation    Unknown

Apparently every problem can be attributed to a misalignment problem. The telescope has troubles with heavily misaligned DUTs. Was resolved by creating different gear-files for each run with pretty precise coordinates of the DUT position calculated for the telescope coordinate system. 

Additionally one has to watch out for misaligned planes of the telescope itself. It was required to allow for more than 2mm offset for the telescope planes behind the DUTs. This can be easily checked by looking at the PreAligner plots in the -hitmaker-histo.root file.

It look something like this:

and not like this:

 

Run number offset value Comment
49 -1  
50 -1 Expected default value. EORE=49401
51 -1 Expected default value. EORE=49400
52 -1 Checked -1 EORE= 49401
53 -1 Checked -1 EORE= 49401
54 -1 Checked -1 EORE= 119401, 
55 -1 Checked -1 EORE= 409388
56 -1 Checked -1 EORE= 49392
57 -1 Checked -1 EORE= 49377
58 -1 Checked -1 EORE= 49397

 

Run Position x-Table x-telescope FW x-telescope BW
49 1 100 -13,7 -16,7
50 2 69,3 17 14
51 3 38,6 47,7 44,7
52 4 130,7 -44,4 -47,4
53 5 30,5 55,8 52,8
54 6 136,8 -50,5 -53,5
55 7 30,5 55,8 52,8
56 8 136,8 -50,5 -53,5
57 9 30,5 55,8 52,8
58 10 136,8 -50,5 -53,5
  58   Mon Jun 8 18:08:49 2015 Thomas BergauerSVD3 (H6B)Telescope online monitor    Unknown

a working version of the EUDET online monitor (which works also with the FE-I4) is at the following location

~/BELLETEST/eudaq-neu/build/monitors/onlinemon$ ./OnlineMon.exe -sc 0 -f /home/telescope/eudaq/data/run000060.raw

  62   Tue Jun 9 09:32:41 2015 Hao YinBelle II FADC (H6A)Pedestal00710000  Good

Room temp, fir002

  63   Tue Jun 9 09:33:33 2015 Hao YinBelle II FADC (H6A)Calibration003   Good

room temp
FIRRun002,
pedestalrun006;
pedestalrun007
 

  66   Tue Jun 9 10:01:03 2015 Lukas BullaSVD3 (H6B)TLU setup info    Unknown

Channels:

  • Upstream vertical -> channel 0; (bitmask 1)
  • Upstream horizontal -> channel 1; (bitmask 2)
  • Downstream vertical -> channel 2; (bitmask 4)
  • Downstream horizontal ->channel 3; (bitmask 8)

 

TLU DuT interface:

DUT Interface Bitmask DAQ
1 1 Mimosa (EUDET Telescope)
2 2 leer
3 4 SVD3
4 8 FE-I4

 

  72   Tue Jun 9 20:30:37 2015 Hao YinBelle II FADC (H6A)FIR004   Good

FIR filer and ADC delay with all sensor and telescope.
Telescope alignment

  73   Tue Jun 9 20:32:46 2015 Hao YinBelle II FADC (H6A)Pedestal00810000 NoGood

Room temp, fir004

  74   Tue Jun 9 20:36:39 2015 Hao YinBelle II FADC (H6A)Hardware02062k NoGood

room temp

FIRRun004, PedestalRun008
telescope alignment

  75   Wed Jun 10 10:40:24 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration004  NoGood

room temp
pedestalrun 008
FIRRun004

max frame pos = 0. frame

[six]
lvl = 20, 30
lat = 95
sam = 20
grp = 8

  76   Wed Jun 10 11:19:33 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration005  NoGood

room temp
pedestalrun 008
FIRRun004

max frame pos = 0. frame

[six]
lvl = 20, 30
lat = 96
sam = 20
grp = 8

  77   Wed Jun 10 12:03:53 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration006  NoGood

room temp
pedestalrun 008
FIRRun004

max frame pos = 1-2-3. frame n side still shifted

[six]
lvl = 20, 30
lat = 97
sam = 20
grp = 8

  78   Wed Jun 10 12:04:27 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration007  NoGood

room temp
pedestalrun 008
FIRRun004

max frame pos = 1-2-3. frame n side still shifted

[six]
lvl = 20, 30
lat = 98
sam = 20
grp = 8

  79   Wed Jun 10 13:12:33 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration010  YesGood

cooled
pedestalrun 008
FIRRun004

max frame pos = 1-2-3. frame n side still shifted

[six]
lvl = 15, 35
lat = 96
sam = 50
grp = 8

  80   Wed Jun 10 18:05:03 2015 Benedikt WürknerSVD3 (H6B)FEI4 configuration   NoUnknown

There are two planes, one fixed upstream and one fixed downstream. 

CIS3WII_6 upstream and CIS2WI_IBL2 downstream.

They are configured using the pc in H6B which can be accessed via microsoft remote desktop from the network 192.168.5.x using the ip 192.168.5.6. 

The configuration files can be found in the folder "E:\ConfigurationCMS\" on the server and are named after the modules. 

Only one of the FEI4 detectors can be used at a time since they are of different generations (FEI4A and FEI4B) which can't be used at the same time with the available USB board. vnc

The configuration for EUDAQ needs to be adapted for the used module by changing the name of the configuration file. 

[Producer.USBpixI4]
SRAM_READOUT_AT = 5
SkipConfiguration = no
UseSingleBoardConfig = no
boards = 230
modules[230] = 1
#upstream
config_file = E:\ConfigurationCMS\CIS3_W11_06_thr1600_7to21ke_modified.cfg.root
#downstream:
#config_file = E:\ConfigurationCMS\CIS2_W02_IBL1_thr1600_7to14_modified.cfg.root
fpga_firmware = E:\icwiki_svn\USBPixI4\host\tags\release-5.3\config\usbpixi4.bit
lvl1_delay = 16
tlu_trigger_data_delay = 10

In my experience switching between the planes also requires a restart of the USBPix DAQ because apparently something is not working with the reload of a different config file afterwards. I had the phenomenon that the DAQ responded like it was working but the datastream was empty. Therefore always check the online monitor for hitmaps. 

  81   Wed Jun 10 18:52:34 2015 Hao YinBelle II FADC (H6A)Pedestal00910000 YesGood

temp: in -22 out -18,
FIRRun004,

  86   Thu Jun 11 11:41:50 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration011  YesGood

cooled
pedestalrun 008
FIRRun004

max frame pos = 1-2-3. frame n side still shifted

[six]
lvl = 15, 35
lat = 96
sam = 50
grp = 8