Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle testbeam at SPS in June 2015, Page 4 of 6  Not logged in ELOG logo
Entry  Sat Jun 13 13:01:39 2015, Hao Yin, Belle II FADC (H6A), Hardware, 029, , 3, No, Good 

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

L3 rotated.
taget: CE, pos 3
 

Entry  Sat Jun 13 16:47:28 2015, Benedikt Würkner, SVD3 (H6B), Mimosa threshold with FEI4, 82, 12000, , No, Good 

Set mimosa threshold to 5 and recorded with FEI4 upstream

L3 already in sensor but not yet configured. 

Probably to noisy to help much

Entry  Sat Jun 13 17:05:35 2015, Benedikt Würkner, SVD3 (H6B), L3 with FEI4, 84, 30000, 1, No, Good Telescope_with_L3.png

L3 sensor at position x: 105, y: 47 hitting apvs: 2&3 on p-side and apv 3 on n-side

Entry  Sat Jun 13 18:02:04 2015, Benedikt Würkner, SVD3 (H6B), L3 with FEI4, 85, 70000, 2, No, Good 

L3 sensor at position x: 115, y: 47 hitting apvs: 2&3 on p-side and apv 3&4 on n-side

Entry  Sat Jun 13 19:14:41 2015, Benedikt Würkner, SVD3 (H6B), L3 with FEI4, 86, 732000, 3, No, Good 

L3 sensor at position x: 115, y: 57 hitting apvs: 1&2 on p-side and apv 3&4 on n-side

Entry  Sat Jun 13 19:26:26 2015, Hao Yin, Belle II FADC (H6A), Hardware, 030, , 3, No, Good 

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

wo L3 and L4
taget: CE, pos 3
 

Entry  Sat Jun 13 19:29:50 2015, Hao Yin, Belle II FADC (H6A), Hardware, 030, , 1, No, Good 

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

wo L3 and L4
taget: bw, pos 1
 

Entry  Tue May 12 10:27:39 2015, Benedikt Würkner, SVD3 (H6B), Setup information, , , , , Unknown spider-config.jpg

Information concerning the SVD3 setup during a beam test

In the beam area setup the whole crate and the power supply with the usual spider cable and the two Keithly 2410 high voltage supplies. Monitoring of the 2410 happens via a NI MAX interface that connects to the GPIB-Ethernet interface and needs to be configured there. The IP and password are noted on the device. The software can be found on heros in medialib/LONGTERM/longterm R3.1_doubleSided as a normal *.vi file. 

Default adresses 16 and 17 as defined in labview, need to figure out on site which is which, if the voltage selected (e.g. 100V) is applied as +50/-50 or if it is applied as +100/-100 before connecting the cables. 

Take a run without dut as well to check the telescope integrity. Without dut in beamline!!!!!

Entry  Wed Jun 3 10:48:42 2015, Benedikt Würkner, common, Networking, , , , , Unknown 

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.174.109 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Benni mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.124 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 SVD3 DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22), VNC(5900)  SSH(9004), VNC(9012)
192.168.0.20 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.19 Cooling control PC VNC(5900) VNC(9011)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
137.138.113.254 Aida PC   vnc(5900)

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

Entry  Wed Jun 3 17:23:07 2015, Thomas Bergauer, Belle II FADC (H6A), XY stage positions, , , , , Unknown L5_Class_B-.PNG

x-Achse: positiv Richtung Saleve (counting room)

y-Achse: positiv Richtung UNTEN!!

 

position of laddertestbox xy stages:

Rev. Pos (BWD Sensor, BWD, Oben) x= 82.3, y=110.6

Mitte Sensor:

Pos 1: (mitte BWD sensor): x=144.74, y=80.8

Pos 2: (mitte Origami -z): x=269.62, y=80.8

Pos 3: (mitte Origami ce): x=394.42, y=80.8

Pos 4 (mitte FWD Micron Sensor): x=517, y=80.8

Ecke:

Pos 5 (Ecke BWD sensor): x=92.3, y=105.6

Pos 6 (Ecke Origami -z): x=217.18, y=105.6

Pos 7 (Ecke Origami ce): x=342.06, y=105.6

Pos 8 (Ecke FWD sensor): x=467,62, y=56,3 

Pos 9 (Ecke FWD sensor): x=568,33 y=64,48

Entry  Thu Jun 4 14:15:50 2015, Hao Yin, Belle II FADC (H6A), FIR, 001, , , , Good 

FIR filer and ADC delay with all sensor and telescope.
telescope n-side switched.

Entry  Thu Jun 4 14:16:20 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 001, 10000, , , Good 

FirRun001, room temp
telescope n-side switched.

Entry  Thu Jun 4 18:45:42 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 003, 10000, , , Good 

firrun003, room temp
 

Entry  Thu Jun 4 18:49:03 2015, Benedikt Würkner, SVD3 (H6B), Setup, , , , , Unknown IMG_20150604_184442.jpgIMG_20150604_184451.jpgIMG_20150604_184516.jpg
 
Entry  Fri Jun 5 12:02:29 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 001, , , , Good 

room temp max subevent at 2. with lat = 96

Entry  Fri Jun 5 12:03:34 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 002, , , , Good 

lat = 97 to a greater range of lat scan

Entry  Fri Jun 5 19:55:00 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 003, , , , Unknown 

lat = 98

room temp

pedestalrun 003

Entry  Fri Jun 5 19:59:44 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 004, 10000, , , Good 

update pedestal values for room temp sixlet runs.
 

Entry  Fri Jun 5 23:38:51 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 005, 10000, , , Unknown 

Readjust after cooling box.

room temp, firrun002
 

Entry  Sat Jun 6 16:14:36 2015, Benedikt Würkner, SVD3 (H6B), calibration run and setup information, cal01, , , , Unknown 

Calibration Run with +- 50V Bias with higher compliance since the p-side draws more current than expected (23muA by the MAMBO)

 

ELOG V3.1.5-fc6679b