Thu Jun 11 15:56:32 2015, Benedikt Würkner, SVD3 (H6B), Hardware FEI4, 73, 20000, 7, No, Unknown
|
RUN WITH SVD3, telescope and FEI4
EUDET Run 73
Mimosa Threshold 6
Pos 7: x= 30.5 mm, y= 79 mm (wide side center)
Upstream FEI4 used, checking if alignment change helped |
Thu Jun 11 11:42:39 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 012, , , Yes, Good
|
cooled until about 400k after that room temp
pedestalrun 009
FIRRun005
sixlet calibration run with only ladders
[six]
lvl = 0, 255
lat = 97
sam = 50
grp = 8 |
Thu Jun 11 11:41:50 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 011, , , Yes, Good
|
cooled
pedestalrun 008
FIRRun004
max frame pos = 1-2-3. frame n side still shifted
[six]
lvl = 15, 35
lat = 96
sam = 50
grp = 8 |
Wed Jun 10 21:36:25 2015, Benedikt Würkner, SVD3 (H6B), Horizontal Beam Profile Run, 72, 50000, 1, No, Good
|
Trying to get a nice plot of the beam profile by only using the and 3 (horizontal) see http://elog.hephy.at/testbeam-SPS2015/66 for details.
Pos 1: x=100 mm, y=79 mm (Hits in APV 3 und 8-9 in p-Seite und 14 und 17 in n-Seite )
Producer.TLU Config Change:
|
Wed Jun 10 20:54:36 2015, Benedikt Würkner, SVD3 (H6B), Residuals FE-I4 (Upstream), 59, , 10, No, Good
|
|
Wed Jun 10 19:07:42 2015, Hao Yin, Belle II FADC (H6A), Hardware, 021, , 5, Yes, Good
|
temp: in -23 out -20
FIRRun002,
PedestalRun010,
Calibrationrun002
taget: BW |
Wed Jun 10 19:05:04 2015, Benedikt Würkner, SVD3 (H6B), Hardware FEI4, 71, 50000, 1, No, Unknown
|
RUN WITH SVD3, telescope and FEI4
EUDET Run 71
Mimosa Threshold 6
Pos 1: x=100 mm, y=79 mm (Hits in APV 3 und 8-9 in p-Seite und 14 und 17 in n-Seite )
Downstream FEI4 used |
Wed Jun 10 18:52:34 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 009, 10000, , Yes, Good
|
temp: in -22 out -18,
FIRRun004, |
Wed Jun 10 18:05:03 2015, Benedikt Würkner, SVD3 (H6B), FEI4 configuration, , , , No, Unknown
|
There are two planes, one fixed upstream and one fixed downstream.
CIS3WII_6 upstream and CIS2WI_IBL2 downstream.
They are configured using the pc in H6B which can be accessed via microsoft remote desktop from the network 192.168.5.x using the ip 192.168.5.6.
The configuration files can be found in the folder "E:\ConfigurationCMS\" on the server and are named after the modules.
Only one of the FEI4 detectors can be used at a time since they are of different generations (FEI4A and FEI4B) which can't be used at the same time with the available USB board. vnc
The configuration for EUDAQ needs to be adapted for the used module by changing the name of the configuration file.
[Producer.USBpixI4]
SRAM_READOUT_AT = 5
SkipConfiguration = no
UseSingleBoardConfig = no
boards = 230
modules[230] = 1
#upstream
config_file = E:\ConfigurationCMS\CIS3_W11_06_thr1600_7to21ke_modified.cfg.root
#downstream:
#config_file = E:\ConfigurationCMS\CIS2_W02_IBL1_thr1600_7to14_modified.cfg.root
fpga_firmware = E:\icwiki_svn\USBPixI4\host\tags\release-5.3\config\usbpixi4.bit
lvl1_delay = 16
tlu_trigger_data_delay = 10
In my experience switching between the planes also requires a restart of the USBPix DAQ because apparently something is not working with the reload of a different config file afterwards. I had the phenomenon that the DAQ responded like it was working but the datastream was empty. Therefore always check the online monitor for hitmaps. |
Wed Jun 10 13:12:33 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 010, , , Yes, Good
|
cooled
pedestalrun 008
FIRRun004
max frame pos = 1-2-3. frame n side still shifted
[six]
lvl = 15, 35
lat = 96
sam = 50
grp = 8 |
Wed Jun 10 12:04:27 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 007, , , No, Good
|
room temp
pedestalrun 008
FIRRun004
max frame pos = 1-2-3. frame n side still shifted
[six]
lvl = 20, 30
lat = 98
sam = 20
grp = 8 |
Wed Jun 10 12:03:53 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 006, , , No, Good
|
room temp
pedestalrun 008
FIRRun004
max frame pos = 1-2-3. frame n side still shifted
[six]
lvl = 20, 30
lat = 97
sam = 20
grp = 8 |
Wed Jun 10 11:19:33 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 005, , , No, Good
|
room temp
pedestalrun 008
FIRRun004
max frame pos = 0. frame
[six]
lvl = 20, 30
lat = 96
sam = 20
grp = 8 |
Wed Jun 10 10:40:24 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 004, , , No, Good
|
room temp
pedestalrun 008
FIRRun004
max frame pos = 0. frame
[six]
lvl = 20, 30
lat = 95
sam = 20
grp = 8 |
Tue Jun 9 20:36:39 2015, Hao Yin, Belle II FADC (H6A), Hardware, 020, 62k, , No, Good
|
room temp
FIRRun004, PedestalRun008
telescope alignment |
Tue Jun 9 20:32:46 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 008, 10000, , No, Good
|
Room temp, fir004 |
Tue Jun 9 20:30:37 2015, Hao Yin, Belle II FADC (H6A), FIR, 004, , , , Good
|
FIR filer and ADC delay with all sensor and telescope.
Telescope alignment |
Tue Jun 9 20:27:55 2015, Benedikt Würkner, SVD3 (H6B), Hardware FEI4, 68, 503505, 8, No, Unknown
|
RUN WITH SVD3, telescope and FEI4
EUDET Run 68
Mimosa Threshold 6
Pos 8: x=136.08 mm, y= 79 mm (narrow side center) |
Tue Jun 9 16:22:59 2015, Benedikt Würkner, SVD3 (H6B), Beam Profile Results, 66 und 67, , 2, No, Good
|
|
Tue Jun 9 14:33:50 2015, Benedikt Würkner, SVD3 (H6B), Vertical Beam Profile Run, 67, 50000, 2, No, Unknown
|
Trying to get a nice plot of the beam profile by only using the vertical PMT 0 (upstream vertical, the long one) see http://elog.hephy.at/testbeam-SPS2015/66 for details.
Pos 2: x=69.3 mm, y=79 mm (Hits in APV 3-4 und 8-9 in p-Seite und 13 und 18 in n-Seite)
Producer.TLU Config Change:
|
|