ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
8
|
Sat Nov 15 12:41:50 2014 |
Benedikt Würkner | Belle SVD | Discoveries during preliminary sensor tests | | | | | Unknown |
L5_p_side APV #3 faulty signal
L4_n_side APV #2 and #3 faulty signal |
Attachment 1: weird_signal.png
|
|
Attachment 2: faulty-signal-l4_n.png
|
|
Attachment 3: faulty-signal_l4_n_2.png
|
|
35
|
Tue Nov 18 20:42:18 2014 |
Benedikt Würkner | Belle SVD | Coordinates of the DUT | | | | | Unknown |
We set the coordinates trying to put the beam in an area with well working APVs
Peak of course differs for n and p sensors due to their different pitch.
L4-6 n-side Peak around strip 180
L4&6 p-side mean value around strip 380
L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320
The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data. |
54
|
Thu Nov 20 10:33:13 2014 |
Benedikt Würkner | Belle SVD | FIRRun and Delay Scan | 003 | | | | Unknown |
Cooled see appendix
with new layout (l3_n-side channels changed and reactivated).
Latest FIRRun |
Attachment 1: Temp_19-11-14.PNG
|
|
55
|
Thu Nov 20 10:39:11 2014 |
Benedikt Würkner | Belle SVD | PedestalRun_009 | | | | | Unknown |
cooled see appendix (FIRRun003)
MaxEvents 10000
|
56
|
Thu Nov 20 10:39:13 2014 |
Benedikt Würkner | Belle SVD | PedestalRun_009 | | | | | Unknown |
cooled see appendix (FIRRun003)
MaxEvents 10000
|
57
|
Thu Nov 20 10:41:54 2014 |
Benedikt Würkner | Belle SVD | CalibrationRun_005 | | | | | Unknown |
cooled see appendix (FIRRun_003)
PedestalRun_009 |
59
|
Thu Nov 20 11:14:19 2014 |
Benedikt Würkner | | HardwareRun_009 | 009 | | | | Crap |
cooling see attachment of FIRRun003
Ped 009
Cal 005
Multi 6 raw mode
L5_n_side out of order
FIFO_FULL_ERROR starting at ~2000 events |
71
|
Fri Nov 21 15:02:28 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 013 | 1433 | | | Unknown |
cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed |
72
|
Fri Nov 21 15:03:08 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 014 | 989 | | | Unknown |
cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed |
73
|
Fri Nov 21 15:07:24 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 019 | 150948 | 2014-11-21 02:41:55 | 2014-11-21 10:11:02 | Unknown |
cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
VME Error, overnight run |
74
|
Fri Nov 21 15:10:19 2014 |
Benedikt Würkner | | HardwareRun | 15-22 (exept 19) | none | | | Crap |
|
93
|
Sat Nov 22 11:37:16 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 036 | 450378 | 2014-11-22 1:00:00 | 2014-11-22 10:27:54 | Unknown |
Not completely cooled since cooling failed at 1:42 in the night
Bias voltage set to +-60V
Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA
Pedestal_013 (cooled)
Noisefile: HardwareRun_036.noi |
Attachment 1: SPS_Testbeam-Temp.xlsx
|
Attachment 2: Screen_Shot_2014-11-22_at_12.41.44.png
|
|
112
|
Sun Nov 23 12:17:59 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 044 | 20000 | | | Unknown |
Hardware Run +-30V Bias
Room Temperature
Pedestal 017 (again marked all the bad strips)
Zero Suppressed |
114
|
Sun Nov 23 12:55:47 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 045 | 20000 | | | Unknown |
Hardware Run +-50V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
Zero Suppressed |
120
|
Sun Nov 23 17:51:44 2014 |
Benedikt Würkner | Belle SVD | HardwareRun | 046 | 100000 | 20:06 | 20:36 | Unknown |
Hardware Run +-60V Bias
Room Temperature
Pedestal 018 (again marked all the bad strips)
Zero Suppressed
|
28
|
Tue Nov 18 12:35:32 2014 |
Axel König | common | Infineon (4 modules) TLU Settings | | | | | Unknown |
- VNC to 192.168.0.18
- In command line: cd C:\Users\telescope\eudaq\bin
- TLUControl.exe.exe -d 2 -a 11 - i RJ45
Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45
Dut Position (left to right): 11, 06, 05, 07 |
30
|
Tue Nov 18 18:29:55 2014 |
Axel König | Infineon | calibration run | Infineon_run002 | | | | Unknown |
Infineon_run002 is just a calibration run for the vertical positioned sensors.
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg |
31
|
Tue Nov 18 18:33:31 2014 |
Axel König | Infineon | hardware run | Infineon_run003 | 300000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 101mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--Stopped 18.11 / 20:20---
Reason: Enough events, adjusting new DUT position for next run
Events: 300000 |
36
|
Tue Nov 18 23:04:34 2014 |
Axel König | Infineon | hardware run | Infineon_run004 | 400000 | | | Unknown |
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0044 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
|
37
|
Wed Nov 19 00:58:27 2014 |
Axel König | Infineon | hardware run | Infineon_run005 | 87000 | | | Unknown |
Infineon new stack - batch 4
multi hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 96mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000 |