86
|
Fri Nov 21 23:34:36 2014 |
Axel König | AIDA | hardware run | AIDA_run009 | 32902 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=5.2190uA
(new table calibration): V:71mm, H:100mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: Run000983
--Stopped 21.11 / 19:20--
DaqEvents: 32902 (-600 ped)
EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)
|
|
87
|
Fri Nov 21 23:40:10 2014 |
Axel König | AIDA | hardware run | AIDA_run010 | 26329 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=5.3470uA
(new table calibration): V:71mm, H:90mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000987
DaqEvents: 26329 (-600 ped)
EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)
|
|
88
|
Sat Nov 22 00:11:36 2014 |
Axel König | AIDA | hardware run | AIDA_run011 | 24916 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=5.3470uA
(new table calibration): V:71mm, H:80mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000988
DaqEvents: 24916 (-600 ped)
EUDAQ EVENTS: DAQ events -600 (+1 trigger offset) |
89
|
Sat Nov 22 00:58:04 2014 |
Axel König | AIDA | hardware run | AIDA_run012 | 276006 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=5.3417uA
(new table calibration): V:51mm, H:70mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000989
DaqEvents: 276006 (-600 ped)
EUDAQ EVENTS: 275390 |
90
|
Sat Nov 22 07:56:33 2014 |
Axel König | AIDA | hardware run | AIDA_run013 | 55629 | | | Unknown |
AIDA
multi hit
Voltage=100V, I=5.3417uA
(new table calibration): V:51mm, H:45mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000990
DaqEvents: 55629 (-600 ped)
EUDAQ EVENTS: 55003
|
|
91
|
Sat Nov 22 10:20:07 2014 |
Axel König | AIDA | calibration run | AIDA_calibration | | | | Unknown |
Calibration run AIDA_calibration
L:\cern14\AIDA |
95
|
Sat Nov 22 16:04:05 2014 |
Axel König | Infineon | Infineon old calibration | Infineon_old_calibration | | | | Unknown |
Calibration run
L:\cern14\infineon_old |
96
|
Sat Nov 22 16:43:18 2014 |
Axel König | common | table, telescope and dut geometry | | | | | Unknown |
geometry files |
Attachment 1: geometry_table.pdf
|
Attachment 2: geometry_DUT.pdf
|
Attachment 3: geometry_infineon_batch4.pdf
|
Attachment 4: geometry_infineon_old.pdf
|
97
|
Sat Nov 22 16:53:39 2014 |
Axel König | Infineon | Infineon old | Infineon_old_run001 | 55000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:97mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000992
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
98
|
Sat Nov 22 17:00:43 2014 |
Axel König | Infineon | Infineon old | damaged strixel sensors, strange IV behaviour | | | | Unknown |
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). |
99
|
Sat Nov 22 18:08:03 2014 |
Axel König | Infineon | hardware run | Infineon_old_run002 | 55000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:102mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000993
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
100
|
Sat Nov 22 19:29:40 2014 |
Axel König | AIDA | DUT Position | | | | | Unknown |
|
Attachment 1: AIDA_DUT_Position.JPG
|
|
101
|
Sun Nov 23 00:20:41 2014 |
Axel König | Infineon | hardware run | Infineon_old_run003 | 30000 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:?, H:?
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000994
DaqEvents: 30000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
102
|
Sun Nov 23 00:24:15 2014 |
Axel König | Infineon | hardware run | Infineon_old_run004 | 168725 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.6529uA
(new table calibration): V:81, H:88
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000996
DaqEvents: 168725 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
103
|
Sun Nov 23 00:51:07 2014 |
Axel König | Infineon | hardware run | Infineon_old_run005 | 26569 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4609uA
(new table calibration): V:75, H:94.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000997
DaqEvents: 26569 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset)
|
|
107
|
Sun Nov 23 09:32:48 2014 |
Axel König | Infineon | hardware run | Infineon_old_run007 | 63913 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:96.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000999
DaqEvents: 63913 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
108
|
Sun Nov 23 09:36:27 2014 |
Axel König | Infineon | hardware run | Infineon_old_run006 | 526562 | | | Unknown |
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:95
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000998
DaqEvents: 526562 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
113
|
Sun Nov 23 12:39:45 2014 |
Axel König | common | PMT's of EUDET (Igor Rubinsky) | | | | | Unknown |
Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen). |