Wed Nov 19 18:20:29 2014, Axel König, Infineon, calibration run, Infineon_run007_cal, , , , Unknown
|
|
Wed Nov 19 21:56:44 2014, Axel König, Infineon, hardware run, Infineon_run008, 244167, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0758 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167 |
Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = 4.0200 µA
strips vertical
Table Position: H: 92.5mm V: 81mm
EUDAQ data: Run951 and Run952
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
-- stopped 20.11 / 09:35--
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer) |
Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown
|
Infineon new stack - batch 4
single hit
HV=300V, total I = ? µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470 |
Thu Nov 20 15:47:56 2014, Axel König, Infineon, hardware run, Infineon_run011, , , , Unknown
|
Infineon new stack - batch 4
faulty!!! |
Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown
|
Infineon new stack - batch 4
single hit + eudaq
HV=100V, total I = 3.0326 µA
strips vertical
Table Position: H: 89mm V: 81mm
data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
eudaq file: run000959.raw
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273 |
Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown
|
Calibration run
L:\cern14\infineon_old |
Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:97mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000992
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown
|
1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.
2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). |
Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:81mm, H:102mm
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000993
DaqEvents: 55000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 00:20:41 2014, Axel König, Infineon, hardware run, Infineon_old_run003, 30000, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.9797uA
(new table calibration): V:?, H:?
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000994
DaqEvents: 30000 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 00:24:15 2014, Axel König, Infineon, hardware run, Infineon_old_run004, 168725, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.6529uA
(new table calibration): V:81, H:88
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000996
DaqEvents: 168725 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 00:51:07 2014, Axel König, Infineon, hardware run, Infineon_old_run005, 26569, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.4609uA
(new table calibration): V:75, H:94.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000997
DaqEvents: 26569 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset)
|
|
Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:96.5
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000999
DaqEvents: 63913 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown
|
Infineon old
multi hit
Voltage=300V, I=10.4028uA
(new table calibration): V:75, H:95
config: L:\cern14\AIDA
data: L:\cern14\AIDA
EUDAQ File: run000998
DaqEvents: 526562 (-600 ped)
EUDAQ EVENTS: daq events - 600 (+2 offset) |
Sat Nov 15 12:41:50 2014, Benedikt Würkner, Belle SVD, Discoveries during preliminary sensor tests, , , , , Unknown
|
L5_p_side APV #3 faulty signal
L4_n_side APV #2 and #3 faulty signal |
Mon Nov 17 22:18:27 2014, Hao Yin, Belle SVD, ADC delay scan, , , Mon Nov 17 22:08:29, , Unknown
|
L3-p: 18
L4-p: 36
L5-p: 33
L6-p: 39
L3-n: 18
L4-n: 36
L5-n: 36
L6-n: 35 |
Mon Nov 17 23:04:57 2014, Hao Yin, Belle SVD, PedestalRun_002, , 10338, Mon Nov 17 23:03:03 CET 2014, , Unknown
|
Pedestal run at room temperature.
6 subevents. Noise reference run.
Delay as latest run.
Reference run for bad strips. |
Tue Nov 18 01:03:18 2014, Hao Yin, Belle SVD, Remapped FADC inputs, , , Tue Nov 18 01:03:32 CET 2014, , Unknown
|
We moved the second cable to the third connector on the FADC to match DESY testbeam conditions. |
Tue Nov 18 01:05:04 2014, Hao Yin, Belle SVD, PedestalRun_003, , , Tue Nov 18 01:03:32 CET 2014, , Unknown
|
New pedestal run after switching the connectors.
At room temperature |
|