Tue Sep 28 22:09:39 2010, Markus Friedl, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in |
Tue Sep 28 22:07:16 2010, Markus Friedl, BELLE, cal, cal002 DO NOT USE -> go to cal003, 83800, 28.09.2010 22:01:55,
|
Belle stack (Origami, Micron, Micron, Origami)
now cooling only for Origami, Micron are uncooled
chiller set point: -25°C, measured values on Origami: -10°C |
Tue Sep 28 16:50:31 2010, Thomas Bergauer, common, serial connection chiller, , , ,
|
Der chiller braucht ein gekreuztes serielles Kabel!! |
Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12
|
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
|
Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31
|
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079 |
Tue Sep 28 14:38:24 2010, Christian Irmler, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in |
Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14
|
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5 |
Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,
|
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC |
Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33
|
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on |
Tue Sep 28 01:13:57 2010, Markus Friedl, BELLE, cal, cal001, 83800, 28.09.2010 01:11:20,
|
first intcal with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on |
Mon Sep 27 18:54:47 2010, Thomas Bergauer, BELLE, XY Position, , , ,
|
center position: 55/40/277,5 |
Mon Sep 27 15:42:09 2010, Thomas Bergauer, common, TLU: wir stecken auf DUT 3, , , ,
|
TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin
TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1 abgeschnittenes Dummykabel
2
EUDRB hinten
4 EUDRB vorne
8 DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1 4 mm (front)
2 |
Mon Sep 27 15:41:28 2010, Thomas Bergauer, common, Szintillatoren, , , ,
|
1: breit (1)
2: schmal (2)
3: breit (4) |
Mon Sep 27 15:39:33 2010, Thomas Bergauer, common, PI-XY Table, , , ,
|
M-521.dd: (links/rechts)
downstream rechts => pos. limit [0]
downstream links => neg. limit [207] |
Fri Sep 24 12:09:32 2010, Manfred Valentan, BELLE, gds-file of Micron wafer, , , ,
|
|
Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , , 6x
|
p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33 |
Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , , 6x
|
p-side: Hybrid 44
alles ok
n-side: Hybrid 34 |
Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , , 6x
|
p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht |
Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , , 6x
|
p-side: Hybrid 41
alles ok
n-side: Hybrid 31 |
Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , , 6x
|
p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
n-side: Hybrid 30 |
|