  HEPHY logbook for testbeam at SPS September/October 2010, Page 7 of 8  Not logged in ELOG logo
Entry  Tue Sep 28 22:09:39 2010, Markus Friedl, BELLE, Temperature sensors Belle stack, , , ,  

PicoLogic TC-08 temperature sensor assignment Belle stack:

Sensor type: K

channel 1:  Origami_mod1_in
channel 2:  Origami_mod1_out
channel 3:  Origami_mod2_out    (swapped with 4)  - label not changed
channel 4:  Origami_mod2_in      (swapped with 3)  - label not changed
channel 5:  Micron_wedge_mod1_p
channel 6:  Micron_wedge_mod1_n
channel 7:  Micron_wedge_mod2_p
channel 8:  Micron_wedge_mod2_n
 

The cooling pipes of the two Origami modules are connected in series, respectively.

Entry  Tue Sep 28 22:07:16 2010, Markus Friedl, BELLE, cal, cal002 DO NOT USE -> go to cal003, 83800, 28.09.2010 22:01:55,  

Belle stack (Origami, Micron, Micron, Origami)

now cooling only for Origami, Micron are uncooled

chiller set point: -25°C, measured values on Origami: -10°C

HV=100V, Ibias=38µA, beam off

modified I2C settings for cold modules

temperature monitoring: Origami2 pipes in<->out swapped (to achieve shorter tubes)

 

PROBLEM: Origami n channels are swapped -> USE cal003 INSTEAD!!!

Entry  Tue Sep 28 16:50:31 2010, Thomas Bergauer, common, serial connection chiller, , , ,  

 Der chiller braucht ein gekreuztes serielles Kabel!!

Entry  Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12 

previous run stopped due to beam problem (shifted, broad, etc).

now recovered, restarting with same settings.

 

telescope run: 20080

Entry  Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31 

same as before, but now pos 1 is located on the other edge (-48mm from center)

telescope 7 / 30 / 277.5

telescope run 20079

Entry  Tue Sep 28 14:38:24 2010, Christian Irmler, BELLE, Temperature sensors Belle stack, , , ,  

PicoLogic TC-08 temperature sensor assignment Belle stack:

Sensor type: K

channel 1:  Origami_mod1_in
channel 2:  Origami_mod1_out
channel 3:  Origami_mod2_in
channel 4:  Origami_mod2_out
channel 5:  Micron_wedge_mod1_p
channel 6:  Micron_wedge_mod1_n
channel 7:  Micron_wedge_mod2_p
channel 8:  Micron_wedge_mod2_n
 

The cooling pipes of the two Origami modules and that of the Micron modules are connected in series, respectively.

Entry  Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14 

now for real (previous run was at wrong position)

all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side

position: 103 / 30 / 277.5

corresponds to telescope run 20078

Entry  Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,  

same as run001 after shifting x by 48mm

103 / 30 / 277.5 ? unsure after crash of xy stage PC

Entry  Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33 

first run with complete Belle stack: 2 x Origami, 2 x Micron

HV=100V  I=49uA

beam is on

chiller is set to 15°C (module temperature is ~17°C)

both Origamis and both Microns are serially cooled

 

position:centered in both axes  55 / 30 / 277.5

 

telescope: run20076 (in zero suppressed mode)

Entry  Tue Sep 28 01:13:57 2010, Markus Friedl, BELLE, cal, cal001, 83800, 28.09.2010 01:11:20,  

first intcal with complete Belle stack: 2 x Origami, 2 x Micron

HV=100V  I=49uA

beam is on

chiller is set to 15°C (module temperature is ~17°C)

both Origamis and both Microns are serially cooled

Entry  Mon Sep 27 18:54:47 2010, Thomas Bergauer, BELLE, XY Position, , , ,  

center position: 55/40/277,5

Entry  Mon Sep 27 15:42:09 2010, Thomas Bergauer, common, TLU: wir stecken auf DUT 3, , , ,  

TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin

TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1   abgeschnittenes Dummykabel
2   EUDRB hinten
4   EUDRB vorne
8   DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1   4 mm (front)
2   4 mm (front)
4   9 mm (back)
8   9 mm (back)
Entry  Mon Sep 27 15:41:28 2010, Thomas Bergauer, common, Szintillatoren, , , ,  

1: breit  (1)

2: schmal (2)

3: breit  (4)

4: schmal  (8)

 

AND aus beiden breiten: 5

AND aus beiden schmalen: 10

 

Entry  Mon Sep 27 15:39:33 2010, Thomas Bergauer, common, PI-XY Table, , , ,  

M-521.dd: (links/rechts)

downstream rechts => pos. limit [0]

downstream links => neg. limit [207]

----------------------

M-511.dd: (oben/unten)

oben [102]

unten [0]

----------------------

M-060.dg: (rotation)

parallel beam [7,5]

 

-------------------------------------------

Remote Control:

lokal ssh tunnel starten:
ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch

danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959). 

Entry  Fri Sep 24 12:09:32 2010, Manfred Valentan, BELLE, gds-file of Micron wafer, , , ,  WaferMicron30.gdsDSSD_layerproperties.lyp
 
Entry  Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , ,  6x

p-side: Hybrid 43
APV3: Streifen 9 schlecht

n-side: Hybrid 33
APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
APV5: 111-128: 4 schlechte Streifen + common mode correction?

ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!

 

 

 

 

 

Entry  Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , ,  6x

p-side: Hybrid 44
alles ok

n-side: Hybrid 34
APV4: zur Gaenze schlecht, APV-Fehler?
APV5: beide Randstreifen schlecht

FUER TRACKING GEEIGNET!

 

 

 

 

 

Entry  Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , ,  6x

p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
APV3: beide Randstreifen etwas schlechter, nicht schlimm

n-side: Hybrid 36
APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
 

ALS DUT AUGENZUDRUECKEN GEEIGNET!
FUER TRACKING GEEIGNET!

 

 

Entry  Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , ,  6x

p-side: Hybrid 41
alles ok

n-side: Hybrid 31
APV4: Streifen 0, 83 schlecht
APV5: Streifen 64, 88, 126 schlecht

ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!

Entry  Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , ,  6x

p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus

n-side: Hybrid 30
APV5: 57-64 schlecht, rebond fail?

ALS DUT GEEIGNET!

 

 

 

 