ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
54
|
Fri Oct 1 23:55:12 2010 |
Thomas Bergauer | CNM | run | run024 | 320k | 01.10.2010 23:53:12 | 02.10.2010 09:47:37 |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
optimized alignment (XY-table to 133/76/187.5)
telescope run 20120 |
Attachment 1: cnm_2d_2.png
|
|
Attachment 2: cnm_2d_1.png
|
|
46
|
Thu Sep 30 18:12:53 2010 |
Markus Friedl | Micron Baby | run | run017 | 35000 | 30.09.2010 18:11:53 | 30.09.2010 20:22:43 |
micron baby: 4 DUTs
HV=100V I=13.5uA, I_stop=17uA
Beam on
15° rotation
telescope run 20111 |
Attachment 1: number_of_clusters_telescope.png
|
|
85
|
Tue Oct 5 10:20:30 2010 |
Manfred Valentan | BELLE | run | run46 | 350000 | 05.10.2010 01:00:00 | 05.10.2010 10:16:07 |
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 15°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -7.5 (rotary table)
telescope run: 20152 |
23
|
Tue Sep 28 15:09:16 2010 |
Markus Friedl | BELLE | run | run005 | 40000 | 28.09.2010 15:07:08 | 28.09.2010 20:20:12 |
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
telescope run: 20080 |
91
|
Wed Oct 6 11:51:25 2010 |
Thomas Bergauer | Micron Baby | run | run049 | 4489 | 06.10.2010 11:38:21 | 06.10.2010 11:49:23 |
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=141uA (start of run)
beam on
not yet optimized XY-table positions (111/43.5/7.5) |
88
|
Tue Oct 5 18:13:05 2010 |
Christian Irmler | ITE | run | run048 | 533125 | 05.10.2010 18:14:57 | 06.10.2010 09:27:44 |
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
telescope run: 20154-20155
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
Attachment 1: LongtermITERun2.png
|
|
58
|
Sat Oct 2 17:24:12 2010 |
Markus Friedl | ITE | run | run026 | 5834 | 02.10.2010 17:23:46 | 02.10.2010 17:31:51 |
2 x SILC + 2 x ITE
HV=100V
trying to find beam
telescope run 20124 |
51
|
Fri Oct 1 10:06:59 2010 |
Manfred Valentan | Micron Baby | run | run021 | 75000 | 01.10.2010 10:07:37 | 01.10.2010 15:24:44 |
micron baby: 4 DUTs
HV=100V I=10.9uA (beginning) 13.6uA (end of run)
Beam on
60° rotation
telescope run 20116 |
Attachment 1: run021_sensordisplay1.jpg
|
|
Attachment 2: hit_map_und_cluster.png
|
|
63
|
Sun Oct 3 08:19:13 2010 |
Markus Friedl | ITE | run | run029 | 75000 | 03.10.2010 08:33:28 | 03.10.2010 10:50:27 |
same as previous run
telescope run 20127
Configuration file for DAQ: cern10_ite_silc_single.cfg --> peak mode with 1 sample! |
52
|
Fri Oct 1 23:18:34 2010 |
Markus Friedl | CNM | run | run022 | 8139 | 01.10.2010 23:17:02 | 01.10.2010 23:45:51 |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
not optimized alignment
telescope run 20118 |
17
|
Tue Sep 28 01:13:57 2010 |
Markus Friedl | BELLE | cal | cal001 | 83800 | 28.09.2010 01:11:20 | |
first intcal with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled |
25
|
Tue Sep 28 22:07:16 2010 |
Markus Friedl | BELLE | cal | cal002 DO NOT USE -> go to cal003 | 83800 | 28.09.2010 22:01:55 | |
Belle stack (Origami, Micron, Micron, Origami)
now cooling only for Origami, Micron are uncooled
chiller set point: -25°C, measured values on Origami: -10°C
HV=100V, Ibias=38µA, beam off
modified I2C settings for cold modules
temperature monitoring: Origami2 pipes in<->out swapped (to achieve shorter tubes)
PROBLEM: Origami n channels are swapped -> USE cal003 INSTEAD!!! |
30
|
Wed Sep 29 09:39:33 2010 |
Markus Friedl | BELLE | cal | cal003 | 83800 | 29.09.2010 09:38:00 | |
same as cal002, but now with corrected readout order |
34
|
Wed Sep 29 14:03:55 2010 |
Markus Friedl | BELLE | cal | cal004 | 83800 | 29.09.2010 14:02:25 | 29.09.2010 14:45:05 |
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=100µA, beam off
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered |
37
|
Wed Sep 29 17:38:19 2010 |
Markus Friedl | Micron Baby | cal | cal005 | 83800 | 29.09.2010 17:36:38 | |
micron baby stack
HV=100V I=6.5uA
Beam off |
44
|
Thu Sep 30 15:06:28 2010 |
Markus Friedl | Micron Baby | cal | cal006 | 83800 | 30.09.2010 15:01:56 | |
micron baby: 4 DUTs - angle scan
HV=100V I=6.8uA
Beam off (turned on at ~8k events)
|
59
|
Sat Oct 2 17:27:14 2010 |
Thomas Bergauer | ITE | cal | cal007 | 83800 | 02.10.2010 17:11:18 | |
ITE: 2 DUTs
2 x SILC + 2 x ITE
HV=100V
Beam on
one short only per sensor |
Attachment 1: intcal_ITE10PAD_W7.png
|
|
Attachment 2: intcal_ITE10PAD_W9.png
|
|
62
|
Sun Oct 3 08:14:39 2010 |
Markus Friedl | ITE | cal | cal008 | 83800 | 03.10.2010 08:13:06 | |
6 x SILC + 2 x ITE
HV=100V
telescope position: 119
no beam (technical problem) |
64
|
Sun Oct 3 14:35:12 2010 |
Marko Dragicevic | CNM | cal | cal009 | 83800 | 03.10.2010 13:50:54 | |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
DUT outside of beam
calibration started after 1 hour warmup |
Attachment 1: cal009_cal_apv6.png
|
|
Attachment 2: cal009_cal_apv7.png
|
|
Attachment 3: slowcontrol_CNM_cal009.gif
|
|
66
|
Sun Oct 3 18:23:27 2010 |
Christian Irmler | Pt | cal | cal010 | 83800 | 03.10.2010 18:26:49 | |
pt modules angle scan
h01-Pt and h02-Pt
currents: h01=23.1µA h02=10.4µA
HV=200V
beam on
modules flushed with dry air
|
Attachment 1: slowcontrol_pt_cal010.gif
|
|