ID Date Author Project Subjectdown Run Number Events StartTime EndTime
  90   Wed Oct 6 11:03:59 2010 Marko DragicevicMicron Babycalcal0138380006.10.2010 11:03:12 

8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off

# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)

ADC delay timing did not change after irradiation (verified)
 

  95   Wed Oct 6 23:03:15 2010 Marko DragicevicBELLEcalcal0148380006.10.2010 23:01:5606.10.2010 23:34:07

Belle stack without Origami2
HV=80V I=227uA

beam on

  97   Fri Oct 8 17:26:36 2010 Markus FriedlBELLEcalcal0158380008.10.2010 17:22:44 

Belle stack without Origami2
HV=11V I=32uA

beam on

2 suspicious APVs on n side of Micron due to burnt strip

trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias)

  100   Fri Oct 8 23:05:03 2010 Markus FriedlBELLEcalcal0168380008.10.2010 23:03:16 

Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
 

Bias connection of Origami repaired --> lower noise on p-side

  104   Sat Oct 9 12:00:55 2010 Christian IrmlerBELLEcalcal0178380009.10.2010 11:59:37 

Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C

Origami p-side does not receive triggers -> disabled

origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...

  80   Mon Oct 4 16:29:36 2010 Christian Irmlercommonbeam settings    

beam settings optimized by beamline operator

wire champer display fixed

Attachment 1: beamprofile_run042.gif
beamprofile_run042.gif
Attachment 2: beamsettings_run042.jpg
beamsettings_run042.jpg
  65   Sun Oct 3 16:23:20 2010 Erik HuemerPtXY/R Position    

centerposition: 119/43/187,5

27 grad: 214,5

  89   Wed Oct 6 10:15:26 2010 Marko DragicevicMicron BabyXY Positions After Irradiation    

center position: 119/50/(7.5)

top left (direction jura, bottom right on sensor): 127/56.5/7.5

bottom right (direction saleve, top left on sensor): 111/43.5/7.5

  38   Wed Sep 29 18:53:05 2010 Thomas BergauerMicron BabyXY Positions    

center position: 113/47/7.5

top left (direction jura): 121/53.5/7.5

bottom right (direction saleve): 105/40.5/7.5

  56   Sat Oct 2 15:24:00 2010 Erik HuemerITEXY Position and Slow Control    

center position: 119/48/187,5

 

Attachment 1: ITE128_SlowControl_FirstRun.png
ITE128_SlowControl_FirstRun.png
  16   Mon Sep 27 18:54:47 2010 Thomas BergauerBELLEXY Position    

center position: 55/40/277,5

  21   Tue Sep 28 14:38:24 2010 Christian IrmlerBELLETemperature sensors Belle stack    

PicoLogic TC-08 temperature sensor assignment Belle stack:

Sensor type: K

channel 1:  Origami_mod1_in
channel 2:  Origami_mod1_out
channel 3:  Origami_mod2_in
channel 4:  Origami_mod2_out
channel 5:  Micron_wedge_mod1_p
channel 6:  Micron_wedge_mod1_n
channel 7:  Micron_wedge_mod2_p
channel 8:  Micron_wedge_mod2_n
 

The cooling pipes of the two Origami modules and that of the Micron modules are connected in series, respectively.

  26   Tue Sep 28 22:09:39 2010 Markus FriedlBELLETemperature sensors Belle stack    

PicoLogic TC-08 temperature sensor assignment Belle stack:

Sensor type: K

channel 1:  Origami_mod1_in
channel 2:  Origami_mod1_out
channel 3:  Origami_mod2_out    (swapped with 4)  - label not changed
channel 4:  Origami_mod2_in      (swapped with 3)  - label not changed
channel 5:  Micron_wedge_mod1_p
channel 6:  Micron_wedge_mod1_n
channel 7:  Micron_wedge_mod2_p
channel 8:  Micron_wedge_mod2_n
 

The cooling pipes of the two Origami modules are connected in series, respectively.

  129   Tue May 17 15:10:52 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, prezupfcal1108380017.05.2011 15:16:2517.05.2011 15:24:35

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=1.7µA

  130   Tue May 17 17:43:24 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, prezupfrun110100k17.05.2011 15:39:3717.05.2011 16:02:54

DUT candidate common p-stop

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.8µA
I_end=2.1µA

n-side: highest 32 strips of APV5 noisy = half of zone 4. Rest okay, DUT candidate

Attachment 1: run110_all_hits_apv4.png
run110_all_hits_apv4.png
Attachment 2: run110_all_hits_apv5.png
run110_all_hits_apv5.png
Attachment 3: cal110_pednoise_apv4.png
cal110_pednoise_apv4.png
Attachment 4: cal110_pednoise_apv5.png
cal110_pednoise_apv5.png
  141   Wed May 18 15:36:03 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, postzupfcal1168380018.05.2011 14:43:1818.05.2011 14:51:31

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_single_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA

every second bond zupfed...

Attachment 1: cal116_goodstrips_apv4.png
cal116_goodstrips_apv4.png
Attachment 2: cal116_goodstrips_apv5.png
cal116_goodstrips_apv5.png
  142   Wed May 18 15:38:29 2011 Manfred ValentanMicron BabyTRK7, source run, unirrad, postzupfrun116100k18.05.2011 15:02:0518.05.2011 15:24:07

TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_multi6_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=2.3µA

every second bond zupfed...

Attachment 1: cal116_goodstrips_apv4.png
cal116_goodstrips_apv4.png
Attachment 2: cal116_goodstrips_apv5.png
cal116_goodstrips_apv5.png
Attachment 3: run116_all_hits_apv4.png
run116_all_hits_apv4.png
Attachment 4: run116_all_hits_apv5.png
run116_all_hits_apv5.png
Attachment 5: cal116_pednoise_apv4.png
cal116_pednoise_apv4.png
Attachment 6: cal116_pednoise_apv5.png
cal116_pednoise_apv5.png
  127   Tue May 17 14:36:36 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, prezupfcal1098380017.05.2011 14:18:1317.05.2011 14:34:25

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.8µA

  128   Tue May 17 14:37:23 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, prezupfrun109100k17.05.2011 14:34:3217.05.2011 15:00:02

DUT candidate combined p-stop

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.9µA
I_end=2.4µA

n-side zone 2 several unusable strips, zone 3 & 4 32 strips each suspicious. Nevertheless DUT candidate!

Attachment 1: run109_all_hits_apv4.png
run109_all_hits_apv4.png
Attachment 2: run109_all_hits_apv5.png
run109_all_hits_apv5.png
Attachment 3: cal109_pednoise_apv4.png
cal109_pednoise_apv4.png
Attachment 4: cal109_pednoise_apv5.png
cal109_pednoise_apv5.png
  139   Wed May 18 14:40:33 2011 Manfred ValentanMicron BabyTRK6, source run, unirrad, postzupfcal1158380018.05.2011 13:41:4418.05.2011 13:49:58

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_single_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA

Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment!

Attachment 1: cal115_goodstrips_apv4.png
cal115_goodstrips_apv4.png
Attachment 2: cal115_goodstrips_apv5.png
cal115_goodstrips_apv5.png
ELOG V3.1.5-fc6679b