ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
90
|
Wed Oct 6 11:03:59 2010 |
Marko Dragicevic | Micron Baby | cal | cal013 | 83800 | 06.10.2010 11:03:12 | |
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
95
|
Wed Oct 6 23:03:15 2010 |
Marko Dragicevic | BELLE | cal | cal014 | 83800 | 06.10.2010 23:01:56 | 06.10.2010 23:34:07 |
Belle stack without Origami2
HV=80V I=227uA
beam on |
97
|
Fri Oct 8 17:26:36 2010 |
Markus Friedl | BELLE | cal | cal015 | 83800 | 08.10.2010 17:22:44 | |
Belle stack without Origami2
HV=11V I=32uA
beam on
2 suspicious APVs on n side of Micron due to burnt strip
trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |
100
|
Fri Oct 8 23:05:03 2010 |
Markus Friedl | BELLE | cal | cal016 | 83800 | 08.10.2010 23:03:16 | |
Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
Bias connection of Origami repaired --> lower noise on p-side |
104
|
Sat Oct 9 12:00:55 2010 |
Christian Irmler | BELLE | cal | cal017 | 83800 | 09.10.2010 11:59:37 | |
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |
80
|
Mon Oct 4 16:29:36 2010 |
Christian Irmler | common | beam settings | | | | |
beam settings optimized by beamline operator
wire champer display fixed |
Attachment 1: beamprofile_run042.gif
|
|
Attachment 2: beamsettings_run042.jpg
|
|
65
|
Sun Oct 3 16:23:20 2010 |
Erik Huemer | Pt | XY/R Position | | | | |
centerposition: 119/43/187,5
27 grad: 214,5 |
89
|
Wed Oct 6 10:15:26 2010 |
Marko Dragicevic | Micron Baby | XY Positions After Irradiation | | | | |
center position: 119/50/(7.5)
top left (direction jura, bottom right on sensor): 127/56.5/7.5
bottom right (direction saleve, top left on sensor): 111/43.5/7.5 |
38
|
Wed Sep 29 18:53:05 2010 |
Thomas Bergauer | Micron Baby | XY Positions | | | | |
center position: 113/47/7.5
top left (direction jura): 121/53.5/7.5
bottom right (direction saleve): 105/40.5/7.5 |
56
|
Sat Oct 2 15:24:00 2010 |
Erik Huemer | ITE | XY Position and Slow Control | | | | |
center position: 119/48/187,5
|
Attachment 1: ITE128_SlowControl_FirstRun.png
|
|
16
|
Mon Sep 27 18:54:47 2010 |
Thomas Bergauer | BELLE | XY Position | | | | |
center position: 55/40/277,5 |
21
|
Tue Sep 28 14:38:24 2010 |
Christian Irmler | BELLE | Temperature sensors Belle stack | | | | |
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in
channel 2: Origami_mod1_out
channel 3: Origami_mod2_in
channel 4: Origami_mod2_out
channel 5: Micron_wedge_mod1_p
channel 6: Micron_wedge_mod1_n
channel 7: Micron_wedge_mod2_p
channel 8: Micron_wedge_mod2_n
The cooling pipes of the two Origami modules and that of the Micron modules are connected in series, respectively. |
26
|
Tue Sep 28 22:09:39 2010 |
Markus Friedl | BELLE | Temperature sensors Belle stack | | | | |
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in
channel 2: Origami_mod1_out
channel 3: Origami_mod2_out (swapped with 4) - label not changed
channel 4: Origami_mod2_in (swapped with 3) - label not changed
channel 5: Micron_wedge_mod1_p
channel 6: Micron_wedge_mod1_n
channel 7: Micron_wedge_mod2_p
channel 8: Micron_wedge_mod2_n
The cooling pipes of the two Origami modules are connected in series, respectively. |
129
|
Tue May 17 15:10:52 2011 |
Manfred Valentan | Micron Baby | TRK7, source run, unirrad, prezupf | cal110 | 83800 | 17.05.2011 15:16:25 | 17.05.2011 15:24:35 |
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=1.7µA |
130
|
Tue May 17 17:43:24 2011 |
Manfred Valentan | Micron Baby | TRK7, source run, unirrad, prezupf | run110 | 100k | 17.05.2011 15:39:37 | 17.05.2011 16:02:54 |
DUT candidate common p-stop
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.8µA
I_end=2.1µA
n-side: highest 32 strips of APV5 noisy = half of zone 4. Rest okay, DUT candidate |
Attachment 1: run110_all_hits_apv4.png
|
|
Attachment 2: run110_all_hits_apv5.png
|
|
Attachment 3: cal110_pednoise_apv4.png
|
|
Attachment 4: cal110_pednoise_apv5.png
|
|
141
|
Wed May 18 15:36:03 2011 |
Manfred Valentan | Micron Baby | TRK7, source run, unirrad, postzupf | cal116 | 83800 | 18.05.2011 14:43:18 | 18.05.2011 14:51:31 |
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_single_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA
every second bond zupfed... |
Attachment 1: cal116_goodstrips_apv4.png
|
|
Attachment 2: cal116_goodstrips_apv5.png
|
|
142
|
Wed May 18 15:38:29 2011 |
Manfred Valentan | Micron Baby | TRK7, source run, unirrad, postzupf | run116 | 100k | 18.05.2011 15:02:05 | 18.05.2011 15:24:07 |
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_multi6_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=2.3µA
every second bond zupfed... |
Attachment 1: cal116_goodstrips_apv4.png
|
|
Attachment 2: cal116_goodstrips_apv5.png
|
|
Attachment 3: run116_all_hits_apv4.png
|
|
Attachment 4: run116_all_hits_apv5.png
|
|
Attachment 5: cal116_pednoise_apv4.png
|
|
Attachment 6: cal116_pednoise_apv5.png
|
|
127
|
Tue May 17 14:36:36 2011 |
Manfred Valentan | Micron Baby | TRK6, source run, unirrad, prezupf | cal109 | 83800 | 17.05.2011 14:18:13 | 17.05.2011 14:34:25 |
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.8µA |
128
|
Tue May 17 14:37:23 2011 |
Manfred Valentan | Micron Baby | TRK6, source run, unirrad, prezupf | run109 | 100k | 17.05.2011 14:34:32 | 17.05.2011 15:00:02 |
DUT candidate combined p-stop
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.9µA
I_end=2.4µA
n-side zone 2 several unusable strips, zone 3 & 4 32 strips each suspicious. Nevertheless DUT candidate! |
Attachment 1: run109_all_hits_apv4.png
|
|
Attachment 2: run109_all_hits_apv5.png
|
|
Attachment 3: cal109_pednoise_apv4.png
|
|
Attachment 4: cal109_pednoise_apv5.png
|
|
139
|
Wed May 18 14:40:33 2011 |
Manfred Valentan | Micron Baby | TRK6, source run, unirrad, postzupf | cal115 | 83800 | 18.05.2011 13:41:44 | 18.05.2011 13:49:58 |
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_single_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA
Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment! |
Attachment 1: cal115_goodstrips_apv4.png
|
|
Attachment 2: cal115_goodstrips_apv5.png
|
|