ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
140
|
Wed May 18 14:42:49 2011 |
Manfred Valentan | Micron Baby | TRK6, source run, unirrad, postzupf | run115 | 100k | 18.05.2011 13:53:54 | 18.05.2011 13:53:54 |
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_multi6_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=1.8µA
Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment! |
Attachment 1: cal115_goodstrips_apv4.png
|
|
Attachment 2: cal115_goodstrips_apv5.png
|
|
Attachment 3: run115_all_hits_apv4.png
|
|
Attachment 4: run115_all_hits_apv5.png
|
|
Attachment 5: cal115_pednoise_apv4.png
|
|
Attachment 6: cal115_pednoise_apv5.png
|
|
125
|
Tue May 17 13:31:32 2011 |
Manfred Valentan | Micron Baby | TRK2, source run, unirrad, prezupf | cal108 | 83800 | 17.05.2011 13:17:17 | 17.05.2011 13:25:27 |
TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA |
126
|
Tue May 17 14:01:45 2011 |
Manfred Valentan | Micron Baby | TRK2, source run, unirrad, prezupf | run108 | 100k | 17.05.2011 13:28:48 | 17.05.2011 13:51:16 |
No DUT candidate (atoll p-stop)
TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA
n-side: APV4 most strips unusable, no DUT candidate |
Attachment 1: run108_all_hits_apv4.png
|
|
Attachment 2: run108_all_hits_apv5.png
|
|
Attachment 3: cal108_pednoise_apv4.png
|
|
Attachment 4: cal108_pednoise_apv5.png
|
|
123
|
Tue May 17 13:02:34 2011 |
Manfred Valentan | Micron Baby | TRK1, source run, unirrad, prezupf | cal107 | 83800 | 17.05.2011 12:20 | 17.05.2011 12:35 |
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA |
124
|
Tue May 17 13:08:08 2011 |
Manfred Valentan | Micron Baby | TRK1, source run, unirrad, prezupf | run107 | 100k | 17.05.2011 12:39:34 | 17.05.2011 13:03:05 |
DUT candidate common p-stop
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA
n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate |
Attachment 1: run107_all_hits_apv4.png
|
|
Attachment 2: run107_all_hits_apv5.png
|
|
Attachment 3: cal107_pednoise_apv4.png
|
|
Attachment 4: cal107_pednoise_apv5.png
|
|
15
|
Mon Sep 27 15:42:09 2010 |
Thomas Bergauer | common | TLU: wir stecken auf DUT 3 | | | | |
TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin
TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1 abgeschnittenes Dummykabel
2 EUDRB hinten
4 EUDRB vorne
8 DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1 4 mm (front)
2 4 mm (front)
4 9 mm (back)
8 9 mm (back) |
14
|
Mon Sep 27 15:41:28 2010 |
Thomas Bergauer | common | Szintillatoren | | | | |
1: breit (1)
2: schmal (2)
3: breit (4)
4: schmal (8)
AND aus beiden breiten: 5
AND aus beiden schmalen: 10
|
101
|
Fri Oct 8 23:22:32 2010 |
Manfred Valentan | BELLE | Schnittwinkel barrel vs. slanted | | | | |
17deg acceptance => Schnittwinkel barrel option = 90-17 = 73deg -----> rotary table 80.5
layer zusätzlich slanted um Winkel alpha => Schnittwinkel = 73 - alpha
slant angles: layer 4: 11.9deg => Schnittwinkel 61.1deg -----> rotary table 68.6
layer 5: 17.2deg => Schnittwinkel 55.8deg -----> rotary table 63.3
layer 6: 21.1deg => Schnittwinkel 51.9deg -----> rotary table 59.4
Im Vergleich mit senkrechtem Durchgang der Teilchen erwarte ich eine Vergrößerung der cluster width um den Faktor tan(Schnittwinkel):
slant layer 4: 1.81
slant layer 5: 1.47
slant layer 6: 1.28
barrel: 3.27 |
42
|
Thu Sep 30 10:56:34 2010 |
Christian Irmler | common | Room numbers | | | | |
Room and telefone numbers.
Name |
Building |
Room |
Tel. |
Bergi |
38 |
418 |
70 418 or 162471 (mobile) |
Markus |
41 |
021 |
60 021 |
Manfred |
38 |
404 |
70 404 |
Erik |
38 |
463 |
70 463 |
Immanuel |
38 |
313 |
70 313 |
Chrisu |
39 |
324 |
79 324
|
Marko |
39 |
007 |
79 007 |
Paqui |
38 |
107 |
70 107 |
|
13
|
Mon Sep 27 15:39:33 2010 |
Thomas Bergauer | common | PI-XY Table | | | | |
M-521.dd: (links/rechts)
downstream rechts => pos. limit [0]
downstream links => neg. limit [207]
----------------------
M-511.dd: (oben/unten)
oben [102]
unten [0]
----------------------
M-060.dg: (rotation)
parallel beam [7,5]
-------------------------------------------
Remote Control:
lokal ssh tunnel starten:
ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch
danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959).
|
3
|
Thu Sep 23 15:32:28 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR | | | | |
p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen
n-side: Hybrid 32
APV4: 0-35 fail
APV5: 10-40, 68 fail
|
Attachment 1: hardrun_2826_7_type4_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_7_type4_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_7_type4_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_7_type4_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_7_type4_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_7_type4_pednoise_apv5.png
|
|
7
|
Thu Sep 23 16:01:10 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby3 -> DUT | | | | |
p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
n-side: Hybrid 30
APV5: 57-64 schlecht, rebond fail?
ALS DUT GEEIGNET!
|
Attachment 1: hardrun_2826_7_type3_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_7_type3_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_7_type3_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_7_type3_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_7_type3_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_7_type3_pednoise_apv5.png
|
|
8
|
Thu Sep 23 16:12:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING | | | | |
p-side: Hybrid 41
alles ok
n-side: Hybrid 31
APV4: Streifen 0, 83 schlecht
APV5: Streifen 64, 88, 126 schlecht
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET! |
Attachment 1: hardrun_single_2826_7_type2_pednoise_apv0.png
|
|
Attachment 2: hardrun_single_2826_7_type2_pednoise_apv1.png
|
|
Attachment 3: hardrun_single_2826_7_type2_pednoise_apv2.png
|
|
Attachment 4: hardrun_single_2826_7_type2_pednoise_apv3.png
|
|
Attachment 5: hardrun_single_2826_7_type2_pednoise_apv4.png
|
|
Attachment 6: hardrun_single_2826_7_type2_pednoise_apv5.png
|
|
9
|
Thu Sep 23 16:19:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING | | | | |
p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
APV3: beide Randstreifen etwas schlechter, nicht schlimm
n-side: Hybrid 36
APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
ALS DUT AUGENZUDRUECKEN GEEIGNET!
FUER TRACKING GEEIGNET!
|
Attachment 1: hardrun_single_2826_1_type4_pednoise_apv0.png
|
|
Attachment 2: hardrun_single_2826_1_type4_pednoise_apv1.png
|
|
Attachment 3: hardrun_single_2826_1_type4_pednoise_apv2.png
|
|
Attachment 4: hardrun_single_2826_1_type4_pednoise_apv3.png
|
|
Attachment 5: hardrun_single_2826_1_type4_pednoise_apv4.png
|
|
Attachment 6: hardrun_single_2826_1_type4_pednoise_apv5.png
|
|
10
|
Thu Sep 23 16:22:33 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby3, TRACKING | | | | |
p-side: Hybrid 44
alles ok
n-side: Hybrid 34
APV4: zur Gaenze schlecht, APV-Fehler?
APV5: beide Randstreifen schlecht
FUER TRACKING GEEIGNET!
|
Attachment 1: hardrun_single_2826_1_type3_pednoise_apv0.png
|
|
Attachment 2: hardrun_single_2826_1_type3_pednoise_apv1.png
|
|
Attachment 3: hardrun_single_2826_1_type3_pednoise_apv2.png
|
|
Attachment 4: hardrun_single_2826_1_type3_pednoise_apv3.png
|
|
Attachment 5: hardrun_single_2826_1_type3_pednoise_apv4.png
|
|
Attachment 6: hardrun_single_2826_1_type3_pednoise_apv5.png
|
|
11
|
Thu Sep 23 16:23:07 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING | | | | |
p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33
APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
APV5: 111-128: 4 schlechte Streifen + common mode correction?
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!
|
Attachment 1: hardrun_2826_1_type2_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_1_type2_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_1_type2_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_1_type2_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_1_type2_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_1_type2_pednoise_apv5.png
|
|
4
|
Thu Sep 23 15:37:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate | | | | |
p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)
APV4: 15-25 hoher noise, keine Fehler zu sehen -> Sensorfehler?
APV5: 127&128 kreuzen sich, beim Behebungsversuch mehr Schaden angerichtet -> besser mal die Finger davon lassen! |
Attachment 1: hardrun_2826_19_type4_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_19_type4_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_19_type4_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_19_type4_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_19_type4_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_19_type4_pednoise_apv5.png
|
|
5
|
Thu Sep 23 15:54:20 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING | | | | |
p-side: Hybrid 47
alles ok
n-side: Hybrid 38
APV5: Streifen 127 hoher Noise
ALS DUT VERWENDEN!
|
Attachment 1: hardrun_2826_19_type3_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_19_type3_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_19_type3_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_19_type3_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_19_type3_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_19_type3_pednoise_apv5.png
|
|
6
|
Thu Sep 23 16:00:31 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby2 -> TRACKING | | | | |
p-side: Hybrid 46
alles ok
n-side: Hybrid 37
APV4: 70-75 schlecht, nix zu sehen -> Sensorfehler
APV5: 115-128 schlecht, rebond fail?
FUER TRACKING GEEIGNET!
|
Attachment 1: hardrun_2826_19_type2_pednoise_apv0.png
|
|
Attachment 2: hardrun_2826_19_type2_pednoise_apv1.png
|
|
Attachment 3: hardrun_2826_19_type2_pednoise_apv2.png
|
|
Attachment 4: hardrun_2826_19_type2_pednoise_apv3.png
|
|
Attachment 5: hardrun_2826_19_type2_pednoise_apv4.png
|
|
Attachment 6: hardrun_2826_19_type2_pednoise_apv5.png
|
|
131
|
Tue May 17 17:44:12 2011 |
Manfred Valentan | Micron Baby | GEW8, source run, unirrad, prezupf | cal111 | 83800 | 17.05.2011 17:51:50 | 17.05.2011 18:00:02 |
GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.6µA |