| ID | Date | Author | Project | Subject | Run Number | Events  | StartTime | EndTime | 
| 70 | Sun Oct  3 22:53:49 2010 | Manfred Valentan | Pt | run | run033 | 25600 | 03.10.2010  22.47:38 | 04.10.2010 00:02:37 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=22.9A h02=6.9A
 HV=200V beam on
 angle: 33
 telescope run 20138 | 
| 72 | Mon Oct  4 09:31:25 2010 | Manfred Valentan | Pt | run | run035 | 25600 | 04.10.2010  09:28:40 |  | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=24.7A h02=11.8A
 HV=200V beam on
 angle: 35 deg
 telescope run 20140 | 
| 73 | Mon Oct  4 10:43:45 2010 | Marko Dragicevic | Pt | run | run036 | 25600 | 04.10.2010  10:33:05 | 04.10.2010  11:35:51 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=24.9A h02=12.5A
 HV=200V beam on
 angle: 39 deg
 telescope run 20142 | 
| 74 | Mon Oct  4 11:43:05 2010 | Christian Irmler | Pt | run | run037 | 25600 | 04.10.2010  11:40:15 | 04.10.2010  12:15:03 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=25.4A h02=13.1A
 HV=200V beam on
 angle: 41 deg
 telescope run 20143 | 
| 75 | Mon Oct  4 12:24:38 2010 | Erik Huemer | Pt | run | run038 | 25600 | 04.10.2010  12:22:09 | 04.10.2010  12:43:40 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.6A h02=13.1A
 HV=200V beam on
 angle: 43 deg
 telescope run 20144 | 
| 76 | Mon Oct  4 12:50:13 2010 | Erik Huemer | Pt | run | run039 --> run out of air --> repeat | 25600 | 04.10.2010  12:45:17 | 04.10.2010 14:00:00 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 45 deg
 run out of dry air  --> h01 run into compliance --> HV turned off during run automatically  --> has to be repeated telescope run 20145 | 
| 77 | Mon Oct  4 14:15:22 2010 | Manfred Valentan | Pt | run | run040 --> unusable --> no bias | 25600 | 04.10.2010  14:?:? | 04.10.2010  14:32:14 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 47 deg
 telescope run 20146 bias voltage has been ramped down during run039 --> needs to be repeated. | 
| 78 | Mon Oct  4 15:39:34 2010 | Christian Irmler | Pt | run | run041 | 25600 | 04.10.2010  15:46:22 |  | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 45 deg
 position axis = 232.5
 repetition of run039 telescope run20147 | 
| 79 | Mon Oct  4 16:15:48 2010 | Christian Irmler | Pt | run | run042 | 25600 | 04.10.2010  16:12:52 | 04.10.2010  16:35:18 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=28.1A h02=2.4A
 HV=200V beam on
 angle: 47 deg
 repetition of run040, but now biased :-) telescope run 20148 | 
| 20 | Tue Sep 28 13:04:02 2010 | Markus Friedl | BELLE | run | run003 | 25000 | 28.09.2010 13:00:05 | 28.09.2010 14:41:14 | 
| now for real (previous run was at wrong position) all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side position: 103 / 30 / 277.5 corresponds to telescope run 20078 | 
| 53 | Fri Oct  1 23:50:28 2010 | Thomas Bergauer | CNM | run | run023 | 2275 | 01.10.2010  23:49:29 | 01.10.2010  23:53:12 | 
| CMN-SILC stackHV_SILC (Katze)=75V, 0.25uA (6 SiLC)
 HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
 too much optimized alignment (XY-table to 133/74/187.5)   ;-) telescope run 20119 | 
| 103 | Sat Oct  9 00:17:02 2010 | Markus Friedl | BELLE | run | run056 | 225k | 09.10.2010  00:15:53 | 09.10.2010  09:54:28 | 
| Belle stack w/o Origami2 after irradiationHV=80V / I_start=255 µA, I_stop=243 µA
 cooling: Origami only, chiller set to -25°C, 2 suspicious APVs on n side of Micron (possibly due to burnt strip)
 same position as in previous run telescope run 20198 - now with correct telescope threshold settings a lot of "Error detected in APV 21, subevent 2. Event discarded, reset sent." errors started at 09.10.2010 09:00:25 (after whole night without any error) | 
| 39 | Wed Sep 29 19:01:28 2010 | Markus Friedl | Micron Baby | run | run012 | 2248 | 29.09.2010  18:59:09 | 29.09.2010  19:07:02 | 
| micron baby stackHV=100V I=11.0uA
 Beam on
 telescope position: 121/55/7.5
   telescope run 20105 | 
| 43 | Thu Sep 30 14:45:16 2010 | Thomas Bergauer | Micron Baby | run | run015 | 22.5k | 30.09.2010  13:18:11 | 30.09.2010  14:38:01 | 
| micron baby stack angle scan 15 grad mit 3 modulen HV=100V, I=3.8uA Beam on   telescope position: 129/76/187.5 telescope run 20109 | 
| 27 | Tue Sep 28 23:23:47 2010 | Markus Friedl | BELLE | run | run006 | 2003 | 28.09.2010  23:13:22 | 28.09.2010  23:22:26 | 
| channels swapped -> stopped | 
| 33 | Wed Sep 29 11:53:16 2010 | Erik Huemer | BELLE | run | run011 | 19003 | 29.09.2010  12:19:57 | 29.09.2010  14:00:57 | 
| Belle stack: Origami-Micron-Micron-Origami HV=100V, Ibias=83.22µA, beam on
 no cooling
 Temp. at modules: Origami 1: 50°C
 Micron 1: 46°C
 Micron 2: 48°C
 Origami 2: 48°C
 
 standard I2C settings
 centered
 telescope run 20085 (continued) | 
| 71 | Mon Oct  4 00:08:55 2010 | Manfred Valentan | Pt | run | run034 | 187000 | 04.10.2010  00:03:18 | 04.10.2010 09:22:07 | 
| Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=21.9A h02=7.5A
 HV=200V beam on
 angle: 37
 telescope run 20139 | 
| 50 | Fri Oct  1 09:42:02 2010 | Erik Huemer | Micron Baby | run | run020 | 1843 | 01.10.2010 09:59:09 | 01.10.2010 10.05 | 
| micron baby: 4 DUTsHV=100V I=10.9uA
 Beam on
 60° rotation
 Teleskop nicht neu gestartet, machma nochamal | 
| 22 | Tue Sep 28 14:48:00 2010 | Markus Friedl | BELLE | run | run004 | 1755 | 28.09.2010 14:48:28 | 28.09.2010 15:06:31 | 
| same as before, but now pos 1 is located on the other edge (-48mm from center) telescope 7 / 30 / 277.5 telescope run 20079 | 
| 96 | Wed Oct  6 23:48:49 2010 | Markus Friedl | BELLE | run | run052 | 165789 | 06.10.2010  23:47:12 | 07.10.2010  08:43:42 | 
| Belle stack without Origami2HV=80V I=217uA
 telescope setting 103 / 30 / 277.5
 telescope run 20184
 temperature of chiller set to 15°C beam stopped at 7.10. 08:00 sharp, no beam until 8.10 - 8:00 according to SPS Page 1. We keep DAQ and telescope running and cross our fingers for at least some spills of particles.   Irradiated micron module 2, n-side: excessive hit count on channels at the edges of the APV chips - no such thing on the p-side |