89
|
Wed Oct 6 10:15:26 2010 |
Marko Dragicevic | Micron Baby | XY Positions After Irradiation | | | | | center position: 119/50/(7.5)
top left (direction jura, bottom
right on sensor): 127/56.5/7.5 |
|
90
|
Wed Oct 6 11:03:59 2010 |
Marko Dragicevic | Micron Baby | cal | cal013 | 83800 | 06.10.2010 11:03:12 | | 8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off |
|
94
|
Wed Oct 6 23:02:09 2010 |
Marko Dragicevic | common | Beam Configuration | | | | | Beam Settings and Profile on 5.10.2010
- 17:00h
Saved as: H6B.801 |
|
95
|
Wed Oct 6 23:03:15 2010 |
Marko Dragicevic | BELLE | cal | cal014 | 83800 | 06.10.2010 23:01:56 | 06.10.2010 23:34:07 | Belle stack without Origami2
HV=80V I=227uA
beam on |
|
3
|
Thu Sep 23 15:32:28 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR | | | | | p-side: Hybrid 42
APV2: viele gerissene bonds der inneren
Bondreihe |
6x |
4
|
Thu Sep 23 15:37:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate | | | | | p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, |
6x |
5
|
Thu Sep 23 15:54:20 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING | | | | | p-side: Hybrid 47
alles ok
n-side: Hybrid 38 |
6x |
6
|
Thu Sep 23 16:00:31 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby2 -> TRACKING | | | | | p-side: Hybrid 46
alles ok
n-side: Hybrid 37 |
6x |
7
|
Thu Sep 23 16:01:10 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby3 -> DUT | | | | | p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet,
ging sich beim Prototyp-Modul an der Stelle |
6x |
8
|
Thu Sep 23 16:12:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING | | | | | p-side: Hybrid 41
alles ok
n-side: Hybrid 31 |
6x |
9
|
Thu Sep 23 16:19:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING | | | | | p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht |
6x |
10
|
Thu Sep 23 16:22:33 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby3, TRACKING | | | | | p-side: Hybrid 44
alles ok
n-side: Hybrid 34 |
6x |
11
|
Thu Sep 23 16:23:07 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING | | | | | p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33 |
6x |
12
|
Fri Sep 24 12:09:32 2010 |
Manfred Valentan | BELLE | gds-file of Micron wafer | | | | | |
|
51
|
Fri Oct 1 10:06:59 2010 |
Manfred Valentan | Micron Baby | run | run021 | 75000 | 01.10.2010 10:07:37 | 01.10.2010 15:24:44 | micron baby: 4 DUTs
HV=100V I=10.9uA (beginning)
13.6uA (end of run) |
|
70
|
Sun Oct 3 22:53:49 2010 |
Manfred Valentan | Pt | run | run033 | 25600 | 03.10.2010 22.47:38 | 04.10.2010 00:02:37 | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A |
|
71
|
Mon Oct 4 00:08:55 2010 |
Manfred Valentan | Pt | run | run034 | 187000 | 04.10.2010 00:03:18 | 04.10.2010 09:22:07 | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=21.9A h02=7.5A |
|
72
|
Mon Oct 4 09:31:25 2010 |
Manfred Valentan | Pt | run | run035 | 25600 | 04.10.2010 09:28:40 | | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A |
|
77
|
Mon Oct 4 14:15:22 2010 |
Manfred Valentan | Pt | run | run040 --> unusable --> no bias | 25600 | 04.10.2010 14:?:? | 04.10.2010 14:32:14 | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A |
|
83
|
Mon Oct 4 23:12:16 2010 |
Manfred Valentan | BELLE | run | run44 | 30000 | 04.10.2010 23:?:? | 04.10.2010 23.57.23 | angle scan Origami 1 and Micron wedge
1