89
|
Wed Oct 6 10:15:26 2010 |
Marko Dragicevic | Micron Baby | XY Positions After Irradiation | | | | |
center position: 119/50/(7.5)
top left (direction jura, bottom right on sensor): 127/56.5/7.5
bottom right (direction saleve, top left on sensor): 111/43.5/7.5 |
90
|
Wed Oct 6 11:03:59 2010 |
Marko Dragicevic | Micron Baby | cal | cal013 | 83800 | 06.10.2010 11:03:12 | |
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
94
|
Wed Oct 6 23:02:09 2010 |
Marko Dragicevic | common | Beam Configuration | | | | |
Beam Settings and Profile on 5.10.2010 - 17:00h
Saved as: H6B.801 |
95
|
Wed Oct 6 23:03:15 2010 |
Marko Dragicevic | BELLE | cal | cal014 | 83800 | 06.10.2010 23:01:56 | 06.10.2010 23:34:07 |
Belle stack without Origami2
HV=80V I=227uA
beam on |
3
|
Thu Sep 23 15:32:28 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR | | | | |
p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen
n-side: Hybrid 32
APV4: 0-35 fail
APV5: 10-40, 68 fail
|
4
|
Thu Sep 23 15:37:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate | | | | |
p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)
APV4: 15-25 hoher noise, keine Fehler zu sehen -> Sensorfehler?
APV5: 127&128 kreuzen sich, beim Behebungsversuch mehr Schaden angerichtet -> besser mal die Finger davon lassen! |
5
|
Thu Sep 23 15:54:20 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING | | | | |
p-side: Hybrid 47
alles ok
n-side: Hybrid 38
APV5: Streifen 127 hoher Noise
ALS DUT VERWENDEN!
|
6
|
Thu Sep 23 16:00:31 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_19_Baby2 -> TRACKING | | | | |
p-side: Hybrid 46
alles ok
n-side: Hybrid 37
APV4: 70-75 schlecht, nix zu sehen -> Sensorfehler
APV5: 115-128 schlecht, rebond fail?
FUER TRACKING GEEIGNET!
|
7
|
Thu Sep 23 16:01:10 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby3 -> DUT | | | | |
p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
n-side: Hybrid 30
APV5: 57-64 schlecht, rebond fail?
ALS DUT GEEIGNET!
|
8
|
Thu Sep 23 16:12:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING | | | | |
p-side: Hybrid 41
alles ok
n-side: Hybrid 31
APV4: Streifen 0, 83 schlecht
APV5: Streifen 64, 88, 126 schlecht
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET! |
9
|
Thu Sep 23 16:19:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING | | | | |
p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
APV3: beide Randstreifen etwas schlechter, nicht schlimm
n-side: Hybrid 36
APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
ALS DUT AUGENZUDRUECKEN GEEIGNET!
FUER TRACKING GEEIGNET!
|
10
|
Thu Sep 23 16:22:33 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby3, TRACKING | | | | |
p-side: Hybrid 44
alles ok
n-side: Hybrid 34
APV4: zur Gaenze schlecht, APV-Fehler?
APV5: beide Randstreifen schlecht
FUER TRACKING GEEIGNET!
|
11
|
Thu Sep 23 16:23:07 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING | | | | |
p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33
APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
APV5: 111-128: 4 schlechte Streifen + common mode correction?
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!
|
12
|
Fri Sep 24 12:09:32 2010 |
Manfred Valentan | BELLE | gds-file of Micron wafer | | | | |
|
51
|
Fri Oct 1 10:06:59 2010 |
Manfred Valentan | Micron Baby | run | run021 | 75000 | 01.10.2010 10:07:37 | 01.10.2010 15:24:44 |
micron baby: 4 DUTs
HV=100V I=10.9uA (beginning) 13.6uA (end of run)
Beam on
60° rotation
telescope run 20116 |
70
|
Sun Oct 3 22:53:49 2010 |
Manfred Valentan | Pt | run | run033 | 25600 | 03.10.2010 22.47:38 | 04.10.2010 00:02:37 |
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A
HV=200V beam on
angle: 33
telescope run 20138 |
71
|
Mon Oct 4 00:08:55 2010 |
Manfred Valentan | Pt | run | run034 | 187000 | 04.10.2010 00:03:18 | 04.10.2010 09:22:07 |
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=21.9A h02=7.5A
HV=200V beam on
angle: 37
telescope run 20139 |
72
|
Mon Oct 4 09:31:25 2010 |
Manfred Valentan | Pt | run | run035 | 25600 | 04.10.2010 09:28:40 | |
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A
HV=200V beam on
angle: 35 deg
telescope run 20140 |
77
|
Mon Oct 4 14:15:22 2010 |
Manfred Valentan | Pt | run | run040 --> unusable --> no bias | 25600 | 04.10.2010 14:?:? | 04.10.2010 14:32:14 |
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
HV=200V beam on
angle: 47 deg
telescope run 20146
bias voltage has been ramped down during run039 --> needs to be repeated. |
83
|
Mon Oct 4 23:12:16 2010 |
Manfred Valentan | BELLE | run | run44 | 30000 | 04.10.2010 23:?:? | 04.10.2010 23.57.23 |
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 30°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -22.5 (rotary table)
telescope run: 20150 |