ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Text |
|
26
|
Tue Sep 28 22:09:39 2010 |
Markus Friedl | BELLE | Temperature sensors Belle stack | | | | | PicoLogic TC-08 temperature sensor assignment
Belle stack:
Sensor type: K |
|
30
|
Wed Sep 29 09:39:33 2010 |
Markus Friedl | BELLE | cal | cal003 | 83800 | 29.09.2010 09:38:00 | | same as cal002, but now with corrected
readout order |
|
37
|
Wed Sep 29 17:38:19 2010 |
Markus Friedl | Micron Baby | cal | cal005 | 83800 | 29.09.2010 17:36:38 | | micron baby stack
HV=100V I=6.5uA
Beam off |
|
38
|
Wed Sep 29 18:53:05 2010 |
Thomas Bergauer | Micron Baby | XY Positions | | | | | center position: 113/47/7.5
top left (direction jura): 121/53.5/7.5
bottom right (direction saleve): |
|
42
|
Thu Sep 30 10:56:34 2010 |
Christian Irmler | common | Room numbers | | | | | Room and telefone numbers.
|
|
44
|
Thu Sep 30 15:06:28 2010 |
Markus Friedl | Micron Baby | cal | cal006 | 83800 | 30.09.2010 15:01:56 | | micron baby: 4 DUTs - angle scan
HV=100V I=6.8uA
Beam off (turned on at ~8k events) |
|
56
|
Sat Oct 2 15:24:00 2010 |
Erik Huemer | ITE | XY Position and Slow Control | | | | | center position: 119/48/187,5
|
|
59
|
Sat Oct 2 17:27:14 2010 |
Thomas Bergauer | ITE | cal | cal007 | 83800 | 02.10.2010 17:11:18 | | ITE: 2 DUTs
2 x SILC + 2 x ITE |
|
62
|
Sun Oct 3 08:14:39 2010 |
Markus Friedl | ITE | cal | cal008 | 83800 | 03.10.2010 08:13:06 | | 6 x SILC + 2 x ITE
HV=100V
telescope position: 119 |
|
64
|
Sun Oct 3 14:35:12 2010 |
Marko Dragicevic | CNM | cal | cal009 | 83800 | 03.10.2010 13:50:54 | | CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, |
|
65
|
Sun Oct 3 16:23:20 2010 |
Erik Huemer | Pt | XY/R Position | | | | | centerposition: 119/43/187,5
27 grad: 214,5 |
|
66
|
Sun Oct 3 18:23:27 2010 |
Christian Irmler | Pt | cal | cal010 | 83800 | 03.10.2010 18:26:49 | | pt modules angle scan
h01-Pt and h02-Pt
currents: h01=23.1µA h02=10.4µA |
|
67
|
Sun Oct 3 18:52:56 2010 |
Christian Irmler | Pt | run | run030 | 25600 | 03.10.2010 19:16:29 | | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=23.1A h02=10.4A |
|
68
|
Sun Oct 3 20:44:40 2010 |
Erik Huemer | Pt | run | run031 | 25600 | 03.10.2010 19:42:34 | | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=20.5A h02=6.5A |
|
72
|
Mon Oct 4 09:31:25 2010 |
Manfred Valentan | Pt | run | run035 | 25600 | 04.10.2010 09:28:40 | | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A |
|
78
|
Mon Oct 4 15:39:34 2010 |
Christian Irmler | Pt | run | run041 | 25600 | 04.10.2010 15:46:22 | | Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A |
|
80
|
Mon Oct 4 16:29:36 2010 |
Christian Irmler | common | beam settings | | | | | beam settings optimized by beamline operator
wire champer display fixed |
|
81
|
Mon Oct 4 20:16:19 2010 |
Christian Irmler | BELLE | cal | cal011 | 83800 | 04.10.2010 20:15:00 | | angle scan Origami 1 and Micron wedge
1
HV = 100V |
|
89
|
Wed Oct 6 10:15:26 2010 |
Marko Dragicevic | Micron Baby | XY Positions After Irradiation | | | | | center position: 119/50/(7.5)
top left (direction jura, bottom
right on sensor): 127/56.5/7.5 |
|
90
|
Wed Oct 6 11:03:59 2010 |
Marko Dragicevic | Micron Baby | cal | cal013 | 83800 | 06.10.2010 11:03:12 | | 8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)