|  Sun Oct  3 22:53:49 2010, Manfred Valentan, Pt, run, run033, 25600, 03.10.2010  22.47:38, 04.10.2010 00:02:37 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=22.9A h02=6.9A
 HV=200V beam on
 angle: 33
 telescope run 20138 |  |  Mon Oct  4 00:08:55 2010, Manfred Valentan, Pt, run, run034, 187000, 04.10.2010  00:03:18, 04.10.2010 09:22:07 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=21.9A h02=7.5A
 HV=200V beam on
 angle: 37
 telescope run 20139 |  |  Mon Oct  4 09:31:25 2010, Manfred Valentan, Pt, run, run035, 25600, 04.10.2010  09:28:40, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=24.7A h02=11.8A
 HV=200V beam on
 angle: 35 deg
 telescope run 20140 |  |  Mon Oct  4 10:43:45 2010, Marko Dragicevic, Pt, run, run036, 25600, 04.10.2010  10:33:05, 04.10.2010  11:35:51 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=24.9A h02=12.5A
 HV=200V beam on
 angle: 39 deg
 telescope run 20142 |  |  Mon Oct  4 11:43:05 2010, Christian Irmler, Pt, run, run037, 25600, 04.10.2010  11:40:15, 04.10.2010  12:15:03 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=25.4A h02=13.1A
 HV=200V beam on
 angle: 41 deg
 telescope run 20143 |  |  Mon Oct  4 12:24:38 2010, Erik Huemer, Pt, run, run038, 25600, 04.10.2010  12:22:09, 04.10.2010  12:43:40 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.6A h02=13.1A
 HV=200V beam on
 angle: 43 deg
 telescope run 20144 |  |  Mon Oct  4 12:50:13 2010, Erik Huemer, Pt, run, run039 --> run out of air --> repeat, 25600, 04.10.2010  12:45:17, 04.10.2010 14:00:00 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 45 deg
 run out of dry air  --> h01 run into compliance --> HV turned off during run automatically  --> has to be repeated telescope run 20145 |  |  Mon Oct  4 14:15:22 2010, Manfred Valentan, Pt, run, run040 --> unusable --> no bias, 25600, 04.10.2010  14:?:?, 04.10.2010  14:32:14 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 47 deg
 telescope run 20146 bias voltage has been ramped down during run039 --> needs to be repeated. |  |  Mon Oct  4 15:39:34 2010, Christian Irmler, Pt, run, run041, 25600, 04.10.2010  15:46:22, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 45 deg
 position axis = 232.5
 repetition of run039 telescope run20147 |  |  Mon Oct  4 16:15:48 2010, Christian Irmler, Pt, run, run042, 25600, 04.10.2010  16:12:52, 04.10.2010  16:35:18 |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=28.1A h02=2.4A
 HV=200V beam on
 angle: 47 deg
 repetition of run040, but now biased :-) telescope run 20148 |  |  Wed May  4 15:14:31 2011, Thomas Bergauer, Pt, info about module, , , , |  | pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch) im Abstand von 2mm uebereinander |  |  Thu Sep 23 15:32:28 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR, , , ,  6x   |  | p-side: Hybrid 42APV2: viele gerissene bonds der inneren Bondreihe
 APV3: gerissene bonds innen
 n-side: Hybrid 32APV4: 0-35 fail
 APV5: 10-40, 68 fail
   |  |  Thu Sep 23 15:37:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate, , , ,  6x   |  | p-side: Hybrid 48alles ok
 n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)APV4: 15-25 hoher noise, keine Fehler zu sehen -> Sensorfehler?
 APV5: 127&128 kreuzen sich, beim Behebungsversuch mehr Schaden angerichtet -> besser mal die Finger davon lassen!
 |  |  Thu Sep 23 15:54:20 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING, , , ,  6x   |  | p-side: Hybrid 47alles ok
 n-side: Hybrid 38APV5: Streifen 127 hoher Noise
 ALS DUT VERWENDEN!   |  |  Thu Sep 23 16:00:31 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby2 -> TRACKING, , , ,  6x   |  | p-side: Hybrid 46alles ok
 n-side: Hybrid 37APV4: 70-75 schlecht, nix zu sehen -> Sensorfehler
 APV5: 115-128 schlecht, rebond fail?
 FUER TRACKING GEEIGNET!       |  |  Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , ,  6x   |  | p-side: Hybrid 40APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
 n-side: Hybrid 30APV5: 57-64 schlecht, rebond fail?
 ALS DUT GEEIGNET!         |  |  Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , ,  6x   |  | p-side: Hybrid 41alles ok
 n-side: Hybrid 31APV4: Streifen 0, 83 schlecht
 APV5: Streifen 64, 88, 126 schlecht
 ALS DUT GEEIGNET!FUER TRACKING GEEIGNET!
 |  |  Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , ,  6x   |  | p-side: Hybrid 45APV0: beide Randstreifen schlecht
 APV1: Streifen 0 schlecht
 APV3: beide Randstreifen etwas schlechter, nicht schlimm
 n-side: Hybrid 36APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
 APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
 
 ALS DUT AUGENZUDRUECKEN GEEIGNET!FUER TRACKING GEEIGNET!
     |  |  Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , ,  6x   |  | p-side: Hybrid 44alles ok
 n-side: Hybrid 34APV4: zur Gaenze schlecht, APV-Fehler?
 APV5: beide Randstreifen schlecht
 
 FUER TRACKING GEEIGNET!
           |  |  Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , ,  6x   |  | p-side: Hybrid 43APV3: Streifen 9 schlecht
 n-side: Hybrid 33APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
 APV5: 111-128: 4 schlechte Streifen + common mode correction?
 ALS DUT GEEIGNET!FUER TRACKING GEEIGNET!
           |  |