|  Fri Oct  8 23:05:03 2010, Markus Friedl, BELLE, cal, cal016, 83800, 08.10.2010  23:03:16, |  | Belle stack w/o Origami2 after irradiationHV=80V / 258 µA
 cooling: Origami only, chiller set to -25°C,
 2 suspicious APVs on n side of Micron due to burnt strip
 
 Bias connection of Origami repaired --> lower noise on p-side |  |  Fri Oct  8 23:22:32 2010, Manfred Valentan, BELLE, Schnittwinkel barrel vs. slanted, , , , |  | 17deg acceptance => Schnittwinkel barrel option = 90-17 = 73deg      ----->  rotary table 80.5 layer zusätzlich slanted um Winkel alpha => Schnittwinkel = 73 - alpha slant angles: layer 4: 11.9deg => Schnittwinkel 61.1deg       ----->  rotary table 68.6layer 5: 17.2deg => Schnittwinkel 55.8deg       ----->  rotary table 63.3
 layer 6: 21.1deg => Schnittwinkel 51.9deg       ----->  rotary table 59.4
 Im Vergleich mit senkrechtem Durchgang der Teilchen erwarte ich eine Vergrößerung der cluster width um den Faktor tan(Schnittwinkel): slant layer 4: 1.81 slant layer 5: 1.47
 slant layer 6: 1.28
 barrel:           3.27
 |  |  Fri Oct  8 23:43:07 2010, Christian Irmler, BELLE, run, run055, 12316, 08.10.2010  23:42:51, 09.10.2010  00:14:56 |  | Belle stack w/o Origami2 after irradiationHV=80V / 255 µA
 cooling: Origami only, chiller set to -25°C,
 2 suspicious APVs on n side of Micron due to burnt strip
 same position as in previous run telescope run 20197  - wrong config file @ telescope -> new run with correct settings |  |  Sat Oct  9 00:17:02 2010, Markus Friedl, BELLE, run, run056, 225k, 09.10.2010  00:15:53, 09.10.2010  09:54:28 |  | Belle stack w/o Origami2 after irradiationHV=80V / I_start=255 µA, I_stop=243 µA
 cooling: Origami only, chiller set to -25°C, 2 suspicious APVs on n side of Micron (possibly due to burnt strip)
 same position as in previous run telescope run 20198 - now with correct telescope threshold settings a lot of "Error detected in APV 21, subevent 2. Event discarded, reset sent." errors started at 09.10.2010 09:00:25 (after whole night without any error) |  |  Sat Oct  9 12:00:55 2010, Christian Irmler, BELLE, cal, cal017, 83800, 09.10.2010  11:59:37, |  | Origami1 (n-side only) + Micron1 (non-irrad)angle scan: 73°
 HV=100V / 40 µA
 cooling: chiller set to 15°C
 Origami p-side does not receive triggers -> disabled origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |  |  Sat Oct  9 12:25:36 2010, Thomas Bergauer, BELLE, run, run057, 276475, 09.10.2010  12:22:21, 09.10.2010  15:08:46 |  |   Origami1 (n-side only) + Micron1 (non-irrad) angle scan: 73 degree HV=100V / 36 uA  (beginning), 35uA (end of run) cooling: chiller set to 15C  PROBLEM: wrong config file (single hit, not multi6) telescope run 20200 
    
        
            | Origami p-side does not receive triggers -> disabled origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...   |  |  |  Sat Oct  9 15:29:09 2010, Markus Friedl, BELLE, run, run058, 30000, 09.10.2010  15:26:50, 09.10.2010  16:21:37 |  | Origami1 (n-side only) + Micron1 (non-irrad)angle scan: 73 - now with multi6 (previous run was single)
 HV=100V / 35uA (beginning of run) 34uA (end of run)
 cooling: chiller set to 15C
 telescope run 20201 
    
        
            | Origami p-side does not receive triggers -> disabled origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...   |  |  |