24
|
Tue Sep 28 16:50:31 2010 |
Thomas Bergauer | common | serial connection chiller | | | | |
Der chiller braucht ein gekreuztes serielles Kabel!! |
135
|
Tue May 17 19:08:29 2011 |
Manfred Valentan | Micron Baby | sensors for source test with intermediate strips | | | | |
Every second bond of these sensors will be removed to mimic the effect of an intermediate strip. For comparison, this is done both with irradiated and unirradiated sensors.
DUT3: B2Micron_2826_7_baby2, common p-stop, irradiated
DUT4: B2Micron_2826_19_baby4, combined p-stop, irradiated
DUT5: B2Micron_2826_19_baby3, atoll p-stop, irradiated (Wolfgang T. took this sensor to the SEM, it's destroyed by now)
TRK6: B2Micron_2826_1_baby4, combined p-stop, unirradiated
TRK7: B2Micron_2826_19_baby2, common p-stop, unirradiated
B2Micron_2826_7_baby3, atoll p-stop, unirradiated
|
116
|
Fri Apr 8 13:25:58 2011 |
Manfred Valentan | Micron Baby | sensors and modules | | | | |
TRK1: B2Micron_2826_1_baby2
TRK2: B2Micron_2826_1_baby3
DUT3: B2Micron_2826_7_baby2 (common p-stop)
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
DUT5: B2Micron_2826_19_baby3 (atoll p-stop)
TRK6: B2Micron_2826_1_baby4
TRK7: B2Micron_2826_19_baby2
GEW: B2Micron_2826_7_baby4
not used: B2Micron_2826_7_baby3 |
18
|
Tue Sep 28 03:06:31 2010 |
Markus Friedl | BELLE | run | run001 | 119516 | 28.09.2010 03:06:04 | 28.09.2010 12:18:33 |
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled
position:centered in both axes 55 / 30 / 277.5
telescope: run20076 (in zero suppressed mode) |
19
|
Tue Sep 28 12:54:33 2010 |
Markus Friedl | BELLE | run | run002 | | 28.09.2010 12:46:54 | |
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC |
20
|
Tue Sep 28 13:04:02 2010 |
Markus Friedl | BELLE | run | run003 | 25000 | 28.09.2010 13:00:05 | 28.09.2010 14:41:14 |
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5
corresponds to telescope run 20078 |
22
|
Tue Sep 28 14:48:00 2010 |
Markus Friedl | BELLE | run | run004 | 1755 | 28.09.2010 14:48:28 | 28.09.2010 15:06:31 |
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079 |
23
|
Tue Sep 28 15:09:16 2010 |
Markus Friedl | BELLE | run | run005 | 40000 | 28.09.2010 15:07:08 | 28.09.2010 20:20:12 |
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
telescope run: 20080 |
27
|
Tue Sep 28 23:23:47 2010 |
Markus Friedl | BELLE | run | run006 | 2003 | 28.09.2010 23:13:22 | 28.09.2010 23:22:26 |
channels swapped -> stopped |
28
|
Tue Sep 28 23:24:35 2010 |
Markus Friedl | BELLE | run | run007 | 1460 | 28.09.2010 23:23:29 | 28.09.2010 23:27:54 |
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20082
sensor config bug (only relevant for sensor display) found -> stopped |
29
|
Tue Sep 28 23:29:50 2010 |
Markus Friedl | BELLE | run | run008 | 140000 | 28.09.2010 23:29:01 | 29.09.2010 09:36:58 |
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20083 |
Attachment 1: run008_sensordisplay.jpg
|
|
Attachment 2: run008_sensordisplay2.jpg
|
|
31
|
Wed Sep 29 10:30:59 2010 |
Markus Friedl | BELLE | run | run009 | 30000 | 29.09.2010 10:27:27 | 29.09.2010 11:06:35 |
zero suppressed (HIT4) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT4
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20084 |
32
|
Wed Sep 29 11:09:10 2010 |
Markus Friedl | BELLE | run | run010 | 30000 | 29.09.2010 11:08:03 | 29.09.2010 11:50:07 |
zero suppressed (HIT5) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT5
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20085 |
33
|
Wed Sep 29 11:53:16 2010 |
Erik Huemer | BELLE | run | run011 | 19003 | 29.09.2010 12:19:57 | 29.09.2010 14:00:57 |
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=83.22µA, beam on
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered
telescope run 20085 (continued) |
39
|
Wed Sep 29 19:01:28 2010 |
Markus Friedl | Micron Baby | run | run012 | 2248 | 29.09.2010 18:59:09 | 29.09.2010 19:07:02 |
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/55/7.5
telescope run 20105 |
40
|
Wed Sep 29 19:08:56 2010 |
Markus Friedl | Micron Baby | run | run013 | 89853 | 29.09.2010 19:09:57 | 30.09.2010 00:52:39 |
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/53.5/7.5 (shifted in height by -1.5mm wrt run012 for better DUT centering)
telescope run 20107 |
Attachment 1: run013_hit.png
|
|
41
|
Thu Sep 30 00:56:32 2010 |
Markus Friedl | Micron Baby | run | run014 | 100k | 30.09.2010 00:55:30 | 30.09.2010 11:20:02 |
micron baby stack
HV=100V I=11.0uA
I_end = 16uA
Beam on
telescope position: 105/40.5/7.5
telescope run 20108 |
43
|
Thu Sep 30 14:45:16 2010 |
Thomas Bergauer | Micron Baby | run | run015 | 22.5k | 30.09.2010 13:18:11 | 30.09.2010 14:38:01 |
micron baby stack angle scan 15 grad mit 3 modulen
HV=100V, I=3.8uA
Beam on
telescope position: 129/76/187.5
telescope run 20109 |
45
|
Thu Sep 30 15:39:53 2010 |
Markus Friedl | Micron Baby | run | run016 | 31k | 30.09.2010 15:38:26 | 30.09.2010 17:44:36 |
micron baby: 4 DUTs
HV=100V I=10.3uA (start of run); I=16.2uA (end of run)
Beam on
reference run @ 0°
telescope run 20110 |
Attachment 1: eventdisplay_schoen.png
|
|
Attachment 2: event_display_nichsoschoen.png
|
|
46
|
Thu Sep 30 18:12:53 2010 |
Markus Friedl | Micron Baby | run | run017 | 35000 | 30.09.2010 18:11:53 | 30.09.2010 20:22:43 |
micron baby: 4 DUTs
HV=100V I=13.5uA, I_stop=17uA
Beam on
15° rotation
telescope run 20111 |
Attachment 1: number_of_clusters_telescope.png
|
|