ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Text |
|
28
|
Tue Sep 28 23:24:35 2010 |
Markus Friedl | BELLE | run | run007 | 1460 | 28.09.2010 23:23:29 | 28.09.2010 23:27:54 | Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, |
|
27
|
Tue Sep 28 23:23:47 2010 |
Markus Friedl | BELLE | run | run006 | 2003 | 28.09.2010 23:13:22 | 28.09.2010 23:22:26 | channels swapped -> stopped |
|
26
|
Tue Sep 28 22:09:39 2010 |
Markus Friedl | BELLE | Temperature sensors Belle stack | | | | | PicoLogic TC-08 temperature sensor assignment
Belle stack:
Sensor type: K |
|
25
|
Tue Sep 28 22:07:16 2010 |
Markus Friedl | BELLE | cal | cal002 DO NOT USE -> go to cal003 | 83800 | 28.09.2010 22:01:55 | | Belle stack (Origami, Micron, Micron, Origami)
now cooling only for Origami, Micron
are uncooled |
|
24
|
Tue Sep 28 16:50:31 2010 |
Thomas Bergauer | common | serial connection chiller | | | | | Der chiller braucht ein gekreuztes
serielles Kabel!! |
|
23
|
Tue Sep 28 15:09:16 2010 |
Markus Friedl | BELLE | run | run005 | 40000 | 28.09.2010 15:07:08 | 28.09.2010 20:20:12 | previous run stopped due to beam problem
(shifted, broad, etc).
now recovered, restarting with same |
|
22
|
Tue Sep 28 14:48:00 2010 |
Markus Friedl | BELLE | run | run004 | 1755 | 28.09.2010 14:48:28 | 28.09.2010 15:06:31 | same as before, but now pos 1 is located
on the other edge (-48mm from center)
telescope 7 / 30 / 277.5 |
|
21
|
Tue Sep 28 14:38:24 2010 |
Christian Irmler | BELLE | Temperature sensors Belle stack | | | | | PicoLogic TC-08 temperature sensor assignment
Belle stack:
Sensor type: K |
|
20
|
Tue Sep 28 13:04:02 2010 |
Markus Friedl | BELLE | run | run003 | 25000 | 28.09.2010 13:00:05 | 28.09.2010 14:41:14 | now for real (previous run was at wrong
position)
all same as run001, except position |
|
19
|
Tue Sep 28 12:54:33 2010 |
Markus Friedl | BELLE | run | run002 | | 28.09.2010 12:46:54 | | same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash
of xy stage PC |
|
18
|
Tue Sep 28 03:06:31 2010 |
Markus Friedl | BELLE | run | run001 | 119516 | 28.09.2010 03:06:04 | 28.09.2010 12:18:33 | first run with complete Belle stack: 2
x Origami, 2 x Micron
HV=100V I=49uA |
|
17
|
Tue Sep 28 01:13:57 2010 |
Markus Friedl | BELLE | cal | cal001 | 83800 | 28.09.2010 01:11:20 | | first intcal with complete Belle stack:
2 x Origami, 2 x Micron
HV=100V I=49uA |
|
16
|
Mon Sep 27 18:54:47 2010 |
Thomas Bergauer | BELLE | XY Position | | | | | center position: 55/40/277,5 |
|
15
|
Mon Sep 27 15:42:09 2010 |
Thomas Bergauer | common | TLU: wir stecken auf DUT 3 | | | | | TLUControl.exe ist auf zenpixell3 unter
/home/eudet/eudaq/bin
TLUControl.exe |
|
14
|
Mon Sep 27 15:41:28 2010 |
Thomas Bergauer | common | Szintillatoren | | | | | 1: breit (1)
2: schmal (2)
3: breit (4) |
|
13
|
Mon Sep 27 15:39:33 2010 |
Thomas Bergauer | common | PI-XY Table | | | | | M-521.dd: (links/rechts)
downstream rechts => pos. limit
[0] |
|
12
|
Fri Sep 24 12:09:32 2010 |
Manfred Valentan | BELLE | gds-file of Micron wafer | | | | | |
|
11
|
Thu Sep 23 16:23:07 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING | | | | | p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33 |
6x |
10
|
Thu Sep 23 16:22:33 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby3, TRACKING | | | | | p-side: Hybrid 44
alles ok
n-side: Hybrid 34 |
6x |
9
|
Thu Sep 23 16:19:54 2010 |
Manfred Valentan | Micron Baby | Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING | | | | | p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht |
6x |