| ID | Date | Author  | Project | Subject | Run Number | Events | StartTime | EndTime | 
| 13 | Mon Sep 27 15:39:33 2010 | Thomas Bergauer | common | PI-XY Table |  |  |  |  | 
| M-521.dd: (links/rechts) downstream rechts => pos. limit [0] downstream links => neg. limit [207] ---------------------- M-511.dd: (oben/unten) oben [102] unten [0] ---------------------- M-060.dg: (rotation) parallel beam [7,5]   ------------------------------------------- Remote Control: 
 lokal ssh tunnel starten:ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch
 danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959).  | 
| 14 | Mon Sep 27 15:41:28 2010 | Thomas Bergauer | common | Szintillatoren |  |  |  |  | 
| 1: breit  (1) 2: schmal (2) 3: breit  (4) 4: schmal  (8)   AND aus beiden breiten: 5 AND aus beiden schmalen: 10   | 
| 15 | Mon Sep 27 15:42:09 2010 | Thomas Bergauer | common | TLU: wir stecken auf DUT 3 |  |  |  |  | 
| TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin 
TLUControl.exe -d 14 -a 12
 
-dXX Mask for DUT:
1   abgeschnittenes Dummykabel
2   EUDRB hinten
4   EUDRB vorne
8   DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1   4 mm (front)
2   4 mm (front)
4   9 mm (back)
8   9 mm (back) | 
| 16 | Mon Sep 27 18:54:47 2010 | Thomas Bergauer | BELLE | XY Position |  |  |  |  | 
| center position: 55/40/277,5 | 
| 24 | Tue Sep 28 16:50:31 2010 | Thomas Bergauer | common | serial connection chiller |  |  |  |  | 
|  Der chiller braucht ein gekreuztes serielles Kabel!! | 
| 35 | Wed Sep 29 16:28:17 2010 | Thomas Bergauer | common | EUDET telescope pedestal run | 20089 | 122850 (events built) | 29.09.2010 16:27 | 29.09.2010 17:33 | 
|  EUDAQ config eudet2-test-6boards-in-2crates rate: ~745.5 Hz   | 
| 36 | Wed Sep 29 17:38:15 2010 | Thomas Bergauer | common | EUDET telescope pedestal run | 20097 | 118125 | 29.09.2010 17:37 | 29.09.2010 18:09 | 
| new pedestal run of EUDET telescope with new JTAG settings of plane 3 (sensor 11) [according to Ingrid]: VRef2    98
 VRef1A  87
 VRef1B  143
 VRef1C  108
 VRef1D   153
   | 
| 38 | Wed Sep 29 18:53:05 2010 | Thomas Bergauer | Micron Baby | XY Positions |  |  |  |  | 
| center position: 113/47/7.5 top left (direction jura): 121/53.5/7.5 bottom right (direction saleve): 105/40.5/7.5 | 
| 43 | Thu Sep 30 14:45:16 2010 | Thomas Bergauer | Micron Baby | run | run015 | 22.5k | 30.09.2010  13:18:11 | 30.09.2010  14:38:01 | 
| micron baby stack angle scan 15 grad mit 3 modulen HV=100V, I=3.8uA Beam on   telescope position: 129/76/187.5 telescope run 20109 | 
| 48 | Thu Sep 30 23:09:29 2010 | Thomas Bergauer | Micron Baby | run | run019 | 162000 | 30.09.2010  23:08:03 | 01.10.2010 9:33:38 | 
| micron baby: 4 DUTsHV=100V I=12uA I_stop=15.4uA
 Beam on
 45° rotation
   telescope run  20115 (after JTAG programming of telescope chips due to config errors) 
 | 
| Attachment 1: run019_sensordisplay1.jpg | 
|  | 
| Attachment 2: Eudet-X_Cluster_Corr-run020115.jpg | 
|  | 
| Attachment 3: Eudet-Num_Clusters-run020115.jpg | 
|  | 
| 53 | Fri Oct  1 23:50:28 2010 | Thomas Bergauer | CNM | run | run023 | 2275 | 01.10.2010  23:49:29 | 01.10.2010  23:53:12 | 
| CMN-SILC stackHV_SILC (Katze)=75V, 0.25uA (6 SiLC)
 HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
 too much optimized alignment (XY-table to 133/74/187.5)   ;-) telescope run 20119 | 
| 54 | Fri Oct  1 23:55:12 2010 | Thomas Bergauer | CNM | run | run024 | 320k | 01.10.2010  23:53:12 | 02.10.2010  09:47:37 | 
| CMN-SILC stackHV_SILC (Katze)=75V, 0.25uA (6 SiLC)
 HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
 optimized alignment (XY-table to 133/76/187.5) telescope run 20120 | 
| Attachment 1: cnm_2d_2.png | 
|  | 
| Attachment 2: cnm_2d_1.png | 
|  | 
| 55 | Sat Oct  2 09:57:20 2010 | Thomas Bergauer | CNM | run | run025 | 150k | 02.10.2010  09:54:28 | 02.10.2010  14:21:20 | 
|  CMN-SILC stack HV_SILC (Katze)=75V, 0.25uA (6 SiLC)HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
 new position along the CNM strips (XY-table to 143/76/187.5) telescope run 20122   | 
| Attachment 1: run20122.png | 
|  | 
| Attachment 2: slowcontrol_cnm.png | 
|  | 
| Attachment 3: cnm_2d_1.png | 
|  | 
| Attachment 4: cnm_2d_2.png | 
|  | 
| 59 | Sat Oct  2 17:27:14 2010 | Thomas Bergauer | ITE | cal | cal007 | 83800 | 02.10.2010 17:11:18 |  | 
| ITE: 2 DUTs2 x SILC + 2 x ITE
 HV=100V
 
 Beam on  one short only per sensor | 
| Attachment 1: intcal_ITE10PAD_W7.png | 
|  | 
| Attachment 2: intcal_ITE10PAD_W9.png | 
|  | 
| 91 | Wed Oct  6 11:51:25 2010 | Thomas Bergauer | Micron Baby | run | run049 | 4489 | 06.10.2010  11:38:21 | 06.10.2010  11:49:23 | 
| 8 x Micron Baby (3 irradiated), no cooling HV=100V I=141uA (start of run) beam on  not yet optimized XY-table positions (111/43.5/7.5) | 
| 105 | Sat Oct  9 12:25:36 2010 | Thomas Bergauer | BELLE | run | run057 | 276475 | 09.10.2010  12:22:21 | 09.10.2010  15:08:46 | 
|   Origami1 (n-side only) + Micron1 (non-irrad) angle scan: 73 degree HV=100V / 36 uA  (beginning), 35uA (end of run) cooling: chiller set to 15C  PROBLEM: wrong config file (single hit, not multi6) telescope run 20200 
    
        
            | Origami p-side does not receive triggers -> disabled origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...   |  | 
| 107 | Sat Oct  9 18:56:35 2010 | Thomas Bergauer | common | path to telescope data |  |  |  |  | 
| eudetmac001.cern.ch path is /Volumes/Data/eudet/Data/cern_2010_sept_silc_apvdaq (Vienna system) and  /Volumes/Data/eudet/Data/cern_2010_sept_silc_alibava (Santander system) | 
| 109 | Sun Oct 10 15:45:04 2010 | Thomas Bergauer | common | end of success |  |  | 09.10.2010  19:44:23 | NaN | 
|  ;-)  genau das gleiche wollte ich auch gerade schreiben! | 
| 120 | Wed May  4 15:14:31 2011 | Thomas Bergauer | Pt | info about module |  |  |  |  | 
| pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch) im Abstand von 2mm uebereinander | 
| 17 | Tue Sep 28 01:13:57 2010 | Markus Friedl | BELLE | cal | cal001 | 83800 | 28.09.2010 01:11:20 |  | 
| first intcal with complete Belle stack: 2 x Origami, 2 x Micron HV=100V  I=49uA beam is on chiller is set to 15°C (module temperature is ~17°C) both Origamis and both Microns are serially cooled |