ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
13
|
Mon Sep 27 15:39:33 2010 |
Thomas Bergauer | common | PI-XY Table | | | | |
M-521.dd: (links/rechts)
downstream rechts => pos. limit [0]
downstream links => neg. limit [207]
----------------------
M-511.dd: (oben/unten)
oben [102]
unten [0]
----------------------
M-060.dg: (rotation)
parallel beam [7,5]
-------------------------------------------
Remote Control:
lokal ssh tunnel starten:
ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch
danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959).
|
14
|
Mon Sep 27 15:41:28 2010 |
Thomas Bergauer | common | Szintillatoren | | | | |
1: breit (1)
2: schmal (2)
3: breit (4)
4: schmal (8)
AND aus beiden breiten: 5
AND aus beiden schmalen: 10
|
15
|
Mon Sep 27 15:42:09 2010 |
Thomas Bergauer | common | TLU: wir stecken auf DUT 3 | | | | |
TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin
TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1 abgeschnittenes Dummykabel
2 EUDRB hinten
4 EUDRB vorne
8 DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1 4 mm (front)
2 4 mm (front)
4 9 mm (back)
8 9 mm (back) |
16
|
Mon Sep 27 18:54:47 2010 |
Thomas Bergauer | BELLE | XY Position | | | | |
center position: 55/40/277,5 |
24
|
Tue Sep 28 16:50:31 2010 |
Thomas Bergauer | common | serial connection chiller | | | | |
Der chiller braucht ein gekreuztes serielles Kabel!! |
35
|
Wed Sep 29 16:28:17 2010 |
Thomas Bergauer | common | EUDET telescope pedestal run | 20089 | 122850 (events built) | 29.09.2010 16:27 | 29.09.2010 17:33 |
EUDAQ config eudet2-test-6boards-in-2crates
rate: ~745.5 Hz
|
36
|
Wed Sep 29 17:38:15 2010 |
Thomas Bergauer | common | EUDET telescope pedestal run | 20097 | 118125 | 29.09.2010 17:37 | 29.09.2010 18:09 |
new pedestal run of EUDET telescope with new JTAG settings of plane 3 (sensor 11) [according to Ingrid]:
VRef2 98
VRef1A 87
VRef1B 143
VRef1C 108
VRef1D 153
|
38
|
Wed Sep 29 18:53:05 2010 |
Thomas Bergauer | Micron Baby | XY Positions | | | | |
center position: 113/47/7.5
top left (direction jura): 121/53.5/7.5
bottom right (direction saleve): 105/40.5/7.5 |
43
|
Thu Sep 30 14:45:16 2010 |
Thomas Bergauer | Micron Baby | run | run015 | 22.5k | 30.09.2010 13:18:11 | 30.09.2010 14:38:01 |
micron baby stack angle scan 15 grad mit 3 modulen
HV=100V, I=3.8uA
Beam on
telescope position: 129/76/187.5
telescope run 20109 |
48
|
Thu Sep 30 23:09:29 2010 |
Thomas Bergauer | Micron Baby | run | run019 | 162000 | 30.09.2010 23:08:03 | 01.10.2010 9:33:38 |
micron baby: 4 DUTs
HV=100V I=12uA I_stop=15.4uA
Beam on
45° rotation
telescope run 20115 (after JTAG programming of telescope chips due to config errors)
|
Attachment 1: run019_sensordisplay1.jpg
|
|
Attachment 2: Eudet-X_Cluster_Corr-run020115.jpg
|
|
Attachment 3: Eudet-Num_Clusters-run020115.jpg
|
|
53
|
Fri Oct 1 23:50:28 2010 |
Thomas Bergauer | CNM | run | run023 | 2275 | 01.10.2010 23:49:29 | 01.10.2010 23:53:12 |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
too much optimized alignment (XY-table to 133/74/187.5) ;-)
telescope run 20119 |
54
|
Fri Oct 1 23:55:12 2010 |
Thomas Bergauer | CNM | run | run024 | 320k | 01.10.2010 23:53:12 | 02.10.2010 09:47:37 |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
optimized alignment (XY-table to 133/76/187.5)
telescope run 20120 |
Attachment 1: cnm_2d_2.png
|
|
Attachment 2: cnm_2d_1.png
|
|
55
|
Sat Oct 2 09:57:20 2010 |
Thomas Bergauer | CNM | run | run025 | 150k | 02.10.2010 09:54:28 | 02.10.2010 14:21:20 |
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
new position along the CNM strips (XY-table to 143/76/187.5)
telescope run 20122
|
Attachment 1: run20122.png
|
|
Attachment 2: slowcontrol_cnm.png
|
|
Attachment 3: cnm_2d_1.png
|
|
Attachment 4: cnm_2d_2.png
|
|
59
|
Sat Oct 2 17:27:14 2010 |
Thomas Bergauer | ITE | cal | cal007 | 83800 | 02.10.2010 17:11:18 | |
ITE: 2 DUTs
2 x SILC + 2 x ITE
HV=100V
Beam on
one short only per sensor |
Attachment 1: intcal_ITE10PAD_W7.png
|
|
Attachment 2: intcal_ITE10PAD_W9.png
|
|
91
|
Wed Oct 6 11:51:25 2010 |
Thomas Bergauer | Micron Baby | run | run049 | 4489 | 06.10.2010 11:38:21 | 06.10.2010 11:49:23 |
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=141uA (start of run)
beam on
not yet optimized XY-table positions (111/43.5/7.5) |
105
|
Sat Oct 9 12:25:36 2010 |
Thomas Bergauer | BELLE | run | run057 | 276475 | 09.10.2010 12:22:21 | 09.10.2010 15:08:46 |
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73 degree
HV=100V / 36 uA (beginning), 35uA (end of run)
cooling: chiller set to 15C
PROBLEM: wrong config file (single hit, not multi6)
telescope run 20200
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...
|
|
107
|
Sat Oct 9 18:56:35 2010 |
Thomas Bergauer | common | path to telescope data | | | | |
eudetmac001.cern.ch
path is /Volumes/Data/eudet/Data/cern_2010_sept_silc_apvdaq (Vienna system)
and /Volumes/Data/eudet/Data/cern_2010_sept_silc_alibava (Santander system) |
109
|
Sun Oct 10 15:45:04 2010 |
Thomas Bergauer | common | end of success | | | 09.10.2010 19:44:23 | NaN |
;-)
genau das gleiche wollte ich auch gerade schreiben! |
120
|
Wed May 4 15:14:31 2011 |
Thomas Bergauer | Pt | info about module | | | | |
pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch)
im Abstand von 2mm uebereinander |
17
|
Tue Sep 28 01:13:57 2010 |
Markus Friedl | BELLE | cal | cal001 | 83800 | 28.09.2010 01:11:20 | |
first intcal with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled |