| ID | Date | Author | Project | Subject | Run Number | Events | StartTime | EndTime  |  | 24 | Sun Jun  1 14:58:53 2008 | Markus Friedl | SiLC | APVDAQ only | ped002 | 10000 | 01.06.2008  14:55:31 | 01.06.2008  14:59:06 |  | SiLC beam test - CERN SPS June 2008 - PEDESTAL
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
software trigger
no telescope
PEDESTAL with BEAM (10k events) @ LEFT |  | 23 | Sun Jun  1 14:36:23 2008 | Markus Friedl | SiLC | APVDAQ only (0-sup) | run0002 | 100000 | 01.06.2008  14:25:43 | 01.06.2008  14:54:14 |  | SiLC beam test - CERN SPS June 2008 - HIT MODE
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12 (manually)
no telescope
This is LEFT position
APVDAQ runs in HIT MODE (=0-suppressed)
acquisition rate ~300 Hz during spill |  | 21 | Sun Jun  1 01:56:47 2008 | Markus Friedl | SiLC | APVDAQ + telescope (0-sup) | run2720 | 100000 | 01.06.2008  01:51:45 | 01.06.2008  07:48:09 |  | SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: zero supressed, new firmware
horizontal position ("target") = -7.5mm
this is LEFT position |  | 20 | Sat May 31 22:54:29 2008 | Markus Friedl | SiLC | APVDAQ + telescope (0-sup) | run2719 | 100000 | 31.05.2008  22:34:38 | 01.06.2008  01:49:30 |  | SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-2.75 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12 (now for real)
telescope: zero supressed, new firmware
horizontal position ("target") = -2.75mm
this is MID position |  | 1 | Tue May  6 13:51:43 2008 | Thomas Bergauer | other | Equipment list |  |  |  |  |  | Slow Control: K2410 SMU
 K2700 Scanning Voltmeter
 Shut-Widerstand-Platine
 Flachbandkabel
 TRHX + 2 Sensoren + Kabel
 Koax-Kabel + Adapter auf Banane
 LV-Power-Supplies
 Die Katze (Belle-HV-Supply)
 
 DAQ:
 Chrisu-PC (inkl. Keyboard, Maus, 2 Monitore)
 9U-VME-Crate samt Modulen und PS
 DOCK-Box
 VME-Kabel (bockig)
 30m-Kabel (8xCat7, 2xCat5, 2xgrau)
 Lemo-Kabel
 100pin-Flachkabel
 Bananenkabel
 Hybridkabel
 Special TLU-Adapter (flipping pin order of RJ45)
 Schrauben für Crate-Montage
 
 DUT:
 9 SiLC-Module
 Micron-Modul
 3 Belle-Module + Rahmen
 Schrauben für Montage am Drehteller
 
 EDV:
 Netzwerkkabel
 Netzwerk-Switch
 WLAN-Router WRT54GL
 1TB externe Festplatte
 Webcam
 USB-Stick
 
 Tools:
 Scope + 4 Probes
 Diverse Adaptoren Lemo-BNC, Lemo-Lemo
 Taschenlampe
 Massband
 Multimeter
 Werkzeug (Schraubenzieher & Co)
 Pinzetten
 Laserpointer
 Schwarze Fetzen
 Scotch tape
 Kabelbinder
 Adapter f. Steckdosen falls erforderlich
 Verteiler-Leisten
 Tixo klein & gross
 
 Misc:
 5 pcs. SiLC Alignment Sensors for Marcos Fernandez Garcia
 Fondueset
  Digitalkamera
 Akkus+Ladegerät
 Dickes Logbook
 Kugelschreiber/Bleistifte
 Pflaster
 VME-6U-PS zur Reparatur
 2 x Pixel-FED für W.J. & D.K.
 |  | 2 | Wed May  7 10:43:09 2008 | Thomas Bergauer | SiLC | Documentation: twiki, Stephans Hardware Drawings,.... |  |  |  |  |  | DUT, APVDAQ DocumentationCERN TWiki: https://twiki.cern.ch/twiki/bin/view/Main/SiLCTestbeam
 Stephan's Documentation: http://wwwhephy.oeaw.ac.at/u3w/s/shaensel/www/HEPHY-Testbeam08/
 
 
 Telescope:EUDAQ @ hepforgeLCIO homepage at DESY
 JRA1 Meeting with Software tutorial (siehe "Software Session" -> "EUtelescope Tutorial")
 |  | 3 | Wed May  7 16:28:23 2008 | stephan hänsel | SiLC | Photos |  |  |  |  |  | Module Photos 
 topview of module (without cover)
 
 bottomview of module (without cover)
 
 8 modules on table
 |  | 4 | Fri May  9 11:46:36 2008 | Markus Friedl | SiLC | Data file format | (work in progress) |  |  |  |  | APVDAQ Data Analysis
====================
The Vienna APVDAQ system has its origin in the late 1990s, and has grown and been improved since then.
Along with the hardware, also the software has grown and hence now consists of several steps rather
than a single piece of software.
DAQ and Analysis Chain
----------------------
Step 0: APVDAQ Software (=online) - CVI/LabWindows under Windows
        * controls and reads hardware, provides quick online analysis for online data quality check
        * can record software (pedestal), hardware (normal) or calibration runs
        * saves raw data (default) or hardware-zero-suppressed data
Step 1: APVDAQ_Analysis - CVI/Labwindows under Windows
        * essentially an improved version of step 0, reads step 0 data from file and performs pedestal 
          subtraction, common-mode correction, hit finding and clump finding (=2D-clustering; we record
          typically 6 samples along the shaped waveform for each event for later peak time reconstruction;
          thus clustering is not only done along strip axis, but also in time -> we search for contiguous
          hit clouds within the two-dimensional x-t-domain and sum up the cluster for each time point)
        * saves clustered waveform hit data (typically 6 sampled values per hit)
Step 2: hitfitgui - ROOT under Linux
        * reads the clustered waveform hit data from step 1 and performs a waveform fit for each hit with the
          reference waveform created from calibration data, resulting in peak amplitude and peak time for each
          hit which is compared to a reference time obtained with a TDC (included in the APVDAQ hardware)
        * saves peak amplitude and time information per hit
Step 3: anarun.C - ROOT under Linux
        * reads the hit properties file from the previous step and fills the data into several histograms like
          Signal, SNR, Noise, Cluster Width, Eta distribution etc. for subsequent graphical display, including
          Landau*Gauss fits and p-n side correlations
        * saves several plot canvasses as PS files
What we don't have
------------------
Tracking, alignment and such things. I think that the best starting point for these functions is the step 2
output data, as this is the most compact form of data and almost directly represents spatial hit points.
General things to consider
--------------------------
* All counting starts from zero
* Strip numbers are counted by hybrids and can span over up to 4 APV chips (=strip numbers 0..511)
* The first 600 events are always software-triggered and used for pedestal and noise evaluation. Thus, event
  numbers 0..599 will never appear in the zero-suppressed data
* The TLU event number is stored separately and does not correspond to the APVDAQ internal event number
* Zones were introduced to label detector regions of different properties, such as the 16 (!) geometrically
  different regions of the SiLC test structures, each comprising only 16 strips
         
Step 1 (APVDAQ_Analysis) output data format
-------------------------------------------
The first step of offline analysis produces a zero-suppressed data file stream out
of the raw data file, thus reducing the file size considerably. 
The zero-suppressed file (file name ends with "_cluster.hit") uses the following structure.
#define MAX_SUBEVENTS       6             // maximum number of samples in one readout buffer
#define MAX_HITS_PER_EVENT  200           // maximum number of hits per event
#define MAX_CLUSTERWIDTH 20               // maximum cluster width
#define P_SIDE	0                         // p-side of the sensor
#define N_SIDE	1                         // n-side of the sensor 
typedef struct {
   unsigned long event;                   // APVDAQ event number
   unsigned char numberofsubevents;	  // number of samples in this event
   unsigned short numberhits;		  // total number of hits (clumps) in this event
   unsigned char hitbegin;  	          // sample number of the begin of the hit
   unsigned char hitlength;     	  // number of samples of this hit
   unsigned short first_strip;		  // first strip of the cluster
   unsigned char clwidth;		  // cluster width
   double center_strip;  		  // center-of-gravity of the cluster (counted in strip units)
   double center_coord;  		  // coordinate of the center strip
   unsigned char side;           	  // sensor side, P_SIDE = 0, N_SIDE = 1
   unsigned char module;                  // module number (internal=0,1,...)
   unsigned char zone;			  // zone number (internal=0,1,...)
   unsigned short tlueventnumber;	  // TLU event number (was previously reserved2)
   double eta;				  // eta of cluster peak
   double clnoise;			  // calibrated cluster noise
   double reserved;			  // used for calibration constant
   double clsigcal[MAX_SUBEVENTS];	  // calibrated cluster signal of all subevents
   double tdc;                            // time of digital conversion
   
   double strsigcal[MAX_CLUSTERWIDTH][MAX_SUBEVENTS];	// calibrated strip signal of all samples
   double strnoise [MAX_CLUSTERWIDTH];			// calibrated strip noise
} Clusterhit_t;
Clusterhit_t clhits[MAX_HITS_PER_EVENT];  // cluster hits of the current event
Each structure array element describes a single clump (2D cluster) found in one sensor plane
in one particular event.
The APV25 chips read out 6 consecutive samples for each strip, spaced by 25ns (MAX_SUBEVENTS).
Hence, the term "cluster" is extended into 2D, with strip number and time sample as coordinates,
leading to a "clump".
A clump is a cluster built from one or more strips and spanning over several time samples.
The total number of clumps per event is stored in the "numberofhits" field, so the procedure
to read the complete event data is to read one element first, then numberofhits-1 more elements.
Step 2 (hitfitgui) output data format
-------------------------------------
The data structure looks very similar to the previous one, except that the (typically) 6 samples values along
the shaped waveform are replaced by a single value pair: peak amplitude and time. Well, actually, there are 3
pairs obtained in different ways, where the last one (i.e. sigcal[2] and tpeak[2]) are most accurate.
The output file (file name ends with "_cluster.hit.fit") uses the following structure.
typedef struct {
   unsigned long event;                 // master event number
   unsigned char numberofsubevents;     // number of subevents in this master event
   unsigned short numberhits;           // total number of hits (clumps) in this event
   unsigned short numfithits;           // total number of fitted hits (clumps) in this event
   unsigned char hitbegin;              // subevent number of the begin of the hit
   unsigned char hitlength;             // number of subevents of this hit
   unsigned short first_strip;          // first strip of the cluster
   unsigned char clwidth;               // cluster width
   double center_strip;                 // center strip of the cluster
   double center_coord;                 // u or v coordinate of the center strip
   unsigned char side;                  // sensor side, N_SIDE, P_SIDE
   unsigned char module;                // module number (internal=0,1,...)
   unsigned char zone;                  // zone number (internal=0,1,...)
   double tdc;                          // time of digital conversion
   double eta;                          // eta of cluster peak
   double clnoise;                      // calibrated cluster noise
// OLD:
//   double reserved;                     // reserved for future use
//
// NEW:
   unsigned short tlueventnumber;	  // TLU event number
   unsigned short reserved2;
   unsigned long reserved3;
   double sigcal[3];                    // fitted hit amplitude {raw data max / expfit / calfit}
   double tpeak[3];                     // fitted peak time {raw data max / expfit / calfit}
   
   double strsigcal[MAX_CLUSTERWIDTH][MAX_SUBEVENTS];	// calibrated strip signal of all samples
   double strnoise [MAX_CLUSTERWIDTH];			// calibrated strip noise
} FittedHit_t;
FittedHit_t fithits[MAX_HITS_PER_EVENT];
Each structure array element describes a single clump (2D cluster) found in one sensor plane
in one particular event.
The total number of clumps per event is stored in the "numberofhits" field, so the procedure
to read the complete event data is to read one element first, then numberofhits-1 more elements.
To be continued... |  | 5 | Fri May  9 15:29:28 2008 | Thomas Bergauer | SiLC | Sensor Layout |  |  |  |  |  | 
    
    
        
            |  | pplus strip | number of |  
            |  | width | intermediate |  
            | strips | [µm] | strips |  
            | 16 | 6 | no |  
            | 16 | 10 | no |  
            | 16 | 12.5 | no |  
            | 16 | 15 | no |  
            | 16 | 20 | no |  
            | 16 | 25 | no |  
            | 16 | 6 | single |  
            | 16 | 7.5 | single |  
            | 16 | 10 | single |  
            | 16 | 12.5 | single |  
            | 16 | 15 | single |  
            | 16 | 17.5 | single |  
            | 16 | 6 | double |  
            | 16 | 7.5 | double |  
            | 16 | 10 | double |  
            | 16 | 12.5 | double |  Stephan: weil ichs immer hier suche hab ich das Wafer Layout file geadded ;-) |  | 6 | Wed May 14 09:21:39 2008 | stephan hänsel | SiLC | capacity measurements - HPK-ILC-TS-6687-24 |  |  |  |  |  | ich hab mal die Kapazitäts-Messungen vom Thomas in ein Diagram gegeben 
 interessant ist, dass die Kapazität mit 2 intermediate strips (int. strips) kleiner ist als mit einem int. strip -> das bedeutet, dass der eine int. strip breiter ist als die 2 int. strips zusammen - oder?
 weiters dürfte die breite des einen int. strips mit der stripwith leicht variieren
 
 (zur Erinnerung: Plattenkondensator - C = e eo A / d )
 |  | 7 | Wed May 14 16:15:30 2008 | Markus Friedl | BELLE | Micron DDD5 Photos |  |  |  |  |  | This is the new Micron DDD5 double-sided module with 3+3 APV25 readout chips on each side. 
 The p-side flex hybrid sits at the edge of the sensor, while the n-side flex hybrid is located on top of about
 1/3 of the sensor, separated by 1mm of Rohacell.
 
 Sensor data (copied from the Micron catalogue):
 
 DESIGN DDD5 - AC COUPLED ION IMPLANTED TOTALLY DEPLETED DOUBLE SIDED DOUBLE METAL MICROSTRIP DETECTOR
 
 SILICON DETECTOR TYPE: AC coupled ion implanted totally depleted silicon microstrip detector.
 DESIGN: Double sided, two metal layers on NN+ 6 inch wafer technology.
 
 JUNCTION SIDE
 No STRIPS: 384
 STRIP PITCH: 50 µm
 
 OHMIC SIDE
 First Metal
 No STRIPS: 768
 STRIP PITCH: 153.5 µm
 Second Metal
 No STRIPS: 384
 STRIP PITCH: 49.5 µm
 
 POLYSILICON RESISTOR: 2.5 ± 0.5 M
 COUPLING CAPACITOR: 100 pF
 SILICON THICKNESS: 300 ± 10 µm
 CHIP DIMENSIONS: 120.125 x 21.2 mm2
 FULL DEPLETION VOLTAGE (FD): 50 V maximum
 OPERATING VOLTAGE: FD to 2FD
 
 EXPERIMENTS: D2, FNAL
 |  | 8 | Mon May 19 15:14:40 2008 | Markus Friedl | other | Tentative Beam Test Schedule |  |  |  |  |  | Wed 28 May: ~16:00 arrival, unpacking
Thu 29 May: installation
Fri 30 May: beam on
1) Telescope + 8xSilC (~7hrs, overnight; first part)
2) 8xSilc, no telescope (fast runs during day)
3) Telescope + 8xSilC (~7hrs, overnight; second part after DUT shift)
4) 1xSilc, rotation
5) Belle, telescope
* starting telescope alignement
* adc delay scan, intcal, pedrun, pedcorr
* DUT alignement
* std. settings, telescope zero supr.(zp) 1st half, lunch break
* std. settings, telescope zero supr. 2nd half
* std. settings, telescope raw data, 1st half
* std. settings, telescope raw data, 2nd half
* optionally HV scan, tel. zp., (10 HV settings --> 2x 10 runs)
* unmount 7 DUTs
* std run 0 deg., (2 runs)
* angle scan (about 10 runs)      
* install Belle DUT
* std. settings, telescope raw, transparent mode
* std. settings, telescope sp, transparent mode, high statistics
* std. settings, telescope sp, processed mode, high statistics |  | 9 | Mon May 19 15:21:49 2008 | Markus Friedl | other | CERN SPS page 1 |  |  |  |  |  | SPS StatusSPS Page 1 - http://hpslweb.cern.ch/frame/java/1.1/view110-java.html
 Manual - http://jwenning.web.cern.ch/jwenning/documents/SPS/Operation/Page-1%20description.htm
 Linac, PSB, CPS StatusLinac, PSB, CPS Status |  | 10 | Fri May 23 15:17:49 2008 | Markus Friedl | SiLC | Module/chip/strip/zone numbering scheme | (work in progress) |  |  |  |  | The SILC DUT is a stack of 8 silicon sensors surrounded by the telescope.
The spacing between each of the 8 layers is 20mm. Seen with the beam, the fourth layer is exactly centered
between the telescope legs. This means that the stack as a whole is not exactly centered, as there is no
'center' module with an even number of layers. Please refer to drawings "telecope_single_dut.gif" and
"telescope_8_dut.gif" below.
Each sensor has 256 strips, which are read out by 2 APV25 chips. The numbering order of the modules follows the
beam direction (see drawing "silc_dut_stack_beam.jpg"). Modules will have the connector (and thus APV25 hybrid)
at the top as shown in the photos. The numbering scheme within one module is shown in drawing
"silc_dut_beam.jpg": Looking with the beam, strips are numbered from right to left. The strip pitch is 50um
everywhere.
The APVDAQ software works on APV25 level for the data acquisition, where raw data is saved. In that case, the
APVs are consecutively numbered 0,1 (=module 0), 2,3 (=module 1), 4,5 (=module 2), ... ,14,15 (=module 7).
In later steps of the analysis, data are presented on a module [0..7] / strip [0..511] base.
Zone numbers were removed, now everything is zone=1.
(Zone 0 is a reserved value and hence the actual zone counting starts with 1.)
The 256 strips are divided into 16 groups of 16 strips each with different strip width and intermediate strips,
according to the table below:
	 	pplus strip  	number of
		width 	intermediate
group#	strips 	[µm] 	strips
 0	16 	6 	none
 1	16 	10 	none
 2	16 	12.5 	none
 3	16 	15 	none
 4	16 	20 	none
 5	16 	25 	none
 6	16 	6 	single
 7	16 	7.5 	single
 8	16 	10 	single
 9	16 	12.5 	single
10	16 	15 	single
11	16 	17.5 	single
12	16 	6 	double
13	16 	7.5 	double
14	16 	10 	double
15	16 	12.5 	double
Please note that the strip pitch is 50µm everywhere, but between each group there is a gap of a single missing
strip. Hence, when calculating the coordinate from the strip number, one must take those distinctive gaps into
account.
We assume that we have a fractional strip position, where the fraction denotes (e.g.) the center of gravity of
the cluster. In order to convert this into a coordinate, we can use the following approach (where s is the
(fractional) strip number and x ist the fractional coordinate [µm]):
 /* *** tested and works *** */
double strip2x(double strip)
{
 unsigned short ints;
 // this is the integral part of the strip number
 ints = (unsigned short) strip;
 
 return ( 50.0 * ( strip + ( ints >> 4 ) ) + ( ( (ints+1) & 15 ) ? 0.0 : ( strip - ints ) * 50.0 ) );
 //       pitch    strip 
 //                          gaps between zones
 //                                                outside gap ? do nothing
 //                                                                      account for double pitch within gap 
    
} |  | 11 | Mon May 26 15:38:53 2008 | Markus Friedl | SiLC | How to run APVDAQ |  |  |  |  |  | Power-on Procedure
==================
PC logon: user "testbeam", pwd "sensor"
Order for switching on the hardware (not strict):
* VME 9U crate
* keithley instruments
* +-5V (fat) 2 lab power supplies (left stack)
* other 3 lab power supplies (right stack)
    BE CAREFUL NOT TO CHANGE DIALS AT ALL DURING SWITCHING!!!
Run ResMan.exe (shortcut on desktop) and click OK to close
Start longterm-R31.vi (shortcut on desktop) and start HV bias
Start APVDAQ.exe 
Now everything is on and ready to operate.
This is also the condition after a run is finished.
Start Run (see screenshot below)
================================
1. select proper run type (if different from previous run), typically
 Hardware (beam) or
 Software (pedestal) or
 Internal Calibration
2. open proper config file (if different from previous run), one of
 cern08_silc_all_single.cfg   (8 DUTs, 1 sample)  - for software (pedestal) and intcal runs
 cern08_silc_all_multi6.cfg   (8 DUTs, 6 samples) - for hardware (beam) runs
 cern08_silc_mod03_single.cfg (1 DUT, module 03, 1 sample)  - for software (pedestal) and intcal runs
 cern08_silc_mod03_multi6.cfg (1 DUT, module 03, 6 samples) - for hardware (beam) runs
 
3. select file name (typically: increase run number)
4. switch Write File ON (if turned off)
5. write some useful comments (conditions, HV, etc)
6. enter number of events
7. hit "Start Run" and relax or cry for help :-)
Additional Info
===============
path to APVDAQ:   e:\cvi-projects\apvdaq_fadc
path to Longterm: e:\labview-projects\longterm R3.1
path to data:     f:\testbeam\cern_jun08\silc\data |  | 12 | Fri May 30 10:36:18 2008 | Marko Dragicevic | other | Important Information/Contact |  |  |  |  |  | IPs Linksys Router
 
 external: routerhephy.cern.ch (137.138.171.102)
internal: 192.168.1.1US&ER /PA_SS'WD: admin/sensor
 
WLAN-SSID: HEPHY
WLAN-WPA-TKIP: testbeam08
 EUDETMAC
 
 external: eudetmac001.cern.ch
U1SE*R/P*AS§S/WD (ssh): eudet/gsigsi
from EUDETMAC to TLU:ssh tlupc
 
 LAB2PC (APVDAQ, DUT HV)
 
 internal: 192.168.1.10
external VNC: routerhephy.cern.ch (137.138.171.102:5900)pa2s2s2w2d: hephy
 
 XY Table
 
 internal VNC: 192.168.1.11pa2s2s2w2d: hephy
 
 Beam Control PC
 
 external VNC: CWO-HNA453-H6B1.CERN.CH (137.138.61.206)
 Phone
 Vienna CERN Mobile Phone (usually Thomas Bergauer)
 
 Daniel Haas
 
 Marko Dragicevic
 
 Hostel (39-120): 79 120
Private: +43 650 4243343
 Markus Friedl
 
 Hostel (41-107): 60 107
Private: +43 699 17251085
 Thomas Bergauer
 
 Hostel (39-220): 79 220
Private: +43 664 3769400 (switched off during testbeam)
 Christian Irmler
 
 Hostel (41-222): 60 222
Private: +43 699 19437327
 Misc
 SPS Page 1
 
 Path to start cesar
 
 |  | 15 | Sat May 31 13:34:28 2008 | Thomas Bergauer |  | how to copy data from lab2pc to eudetmac |  |  |  |  |  | rsync -rltvz --exclude "data_vie" --exclude "hitfit_cern08" --exclude "output_vie" --exclude "run2719*" --rsh="ssh -C -p222" friedl@routerhephy.cern.ch:/cygdrive/f/testbeam/cern_jun08/ /Volumes/Data/eudet/APVDAQ/ 
 but replace run2719 with the name of the run file currently active (data taking)
 
 and use Markus' password
 |  | 19 | Sat May 31 18:33:50 2008 | Thomas Bergauer | other | beam profile |  |  |  |  |  | Beam configuration Beam configuration file: H6b.802 (FM HAD (P0 off, H8=+180) PARLALLEL IN H6B SILC 2008
 
 Rate: 5.7E5 particles/spill (measured with SCINT8 in beamline)
 
 Particle Production Applet
 Calculator applet
 
 For +120 Gev/c beam:
 
 
 | Pi+ | 55.67 % |  | p | 38.95 % |  | K+ | 5.38 % | 
 |  | 29 | Sun Jun  1 17:01:12 2008 | Thomas Bergauer | SiLC | path do data |  |  |  |  |  | The data of all runs are stored on eudetmac001.cern.ch: 
 APVDAQ: /Volumes/Data/eudet/APVDAQ/silc/data
 
 Telescope data: /Volumes/Data/eudet/Data/testing
 
 all data will be saved to an external Firewire disk (Vienna Backup) and to CASTOR
 |  | 30 | Sun Jun  1 18:23:38 2008 | Markus Friedl | SiLC | Very simple tracking | run2719 | 100000 |  |  |  | Very simple alignment (manual linear x direction shifting only, no rotation, assuming equal z spacing) and tracking.
Reference plane = Module 3 (~center)
Deviation calculated from track prediction using the other layers.
Simple Center-of-gravity algorithm (as of APVDAQ_Analysis), no eta applied.
Using only events which have exactly 1 hit per plane (~80% of all events).
Results: 
 Residual RMS = 4.99 um (REFERENCE against neighbor layers 2+4 only)
 Residual RMS = 6.35 um (REFERENCE against all 7 other layers) -> needs more sophisticated alignment |  |