  Testbeams at MedAustron in 2024, Page 8 of 11  Not logged in ELOG logo
Entry  Sat Dec 14 13:42:52 2024, Felix Ulrich-Pur, threshold and preamp tests , 27, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 12:52, 13:16, 24, , ,  
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)

Diamond: 900mA, threshold 50
Entry  Sat Dec 14 13:45:34 2024, Felix Ulrich-Pur, threshold and preamp tests , 28, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 13:20, 13:32, 2, , ,  
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)

Diamond: 900mA, threshold 1000 offset
Entry  Sat Jun 8 21:41:04 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 9, TOF-Cal GSI, 62.4 MeV, Low Flux High, Proton, Good, 20:55, 21:21, , , ,  
changed back to high due to beamsize vs LGAD size factor
650 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 230kHz on LGAD

TOF Calibration Curve
Entry  Sun Aug 25 12:51:10 2024, tb-crew, only base, 71, RD50-MPW4, 62.4 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 12:40:41, 25.08.2024 12:51:37, 10, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 71
Comment:
E-scan
Entry  Sun Aug 25 13:04:26 2024, tb-crew, only base, , RD50-MPW4, 62.4 MeV, Low Flux Very Low, Proton, Unknown, , , , Normal, ,  
End of (promising) shift
Entry  Sat Dec 14 15:50:19 2024, Felix Ulrich-Pur, LGAD+Diamond test with clinical carbon beam, 80, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, , Carbon, Good, 05:15, 05:50, 35, , ,  
Carbon Deg10 (clinical rate)

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Jun 8 19:53:47 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Test High Rate, 1, TOF-Cal GSI, 252.7 MeV, Low Flux High, Proton, Good, 16:00, 16:18, , , ,  
7.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 2.5 MHz on LGAD
Entry  Sat Jun 8 19:56:37 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 2, TOF-Cal GSI, 252.7 MeV, Low Flux Medium, Proton, Good, 16:29, 16:47, , , ,  
1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD

TOF Calibration Curve
Entry  Sun Aug 25 11:35:21 2024, tb-crew, only base, 67, RD50-MPW4, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 11:35:33, 25.08.2024 11:35:48, 0, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 67
Comment:
E-scan
Entry  Sun Aug 25 12:00:00 2024, tb-crew, only base, 68, RD50-MPW4, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 11:37:41, 25.08.2024 12:00:27, 22, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 68
Comment:
E-scan
Entry  Fri Dec 13 11:48:21 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 1, RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 06:28, 06:30, 2, , ,  
Mean rate per spill~ 4-6E5 p/s (online estimation without proper analysis)
Entry  Sat Dec 14 12:56:05 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 8, RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 06:39, 06:40, 1, , ,  
Mean rate per spill~ 5e6 p/s (online estimation without proper analysis)
Entry  Sat Dec 14 13:07:15 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 17, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 08:46, 09:42, 56, , ,  
before run, setups had to be aligned (first slab in slabholder was put in isocentre. However, in this run, no slab was used). Room was closed at 08:10

Beam->Nozzle-> Slabholder->TOF-CAL (TRB)-> DOGMA Setup(Diamond+LGADs)-> RaMon
Entry  Sat Dec 14 13:16:33 2024, Felix Ulrich-Pur, Energy vs TOF calibration +Alignment of DOGMA setup, 18, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 09:42, 09:48, 6, , ,  
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

DOGMA setup had to be shifted manually to align it with the beam
Entry  Sat Dec 14 13:46:11 2024, Felix Ulrich-Pur, WET measurement slabs, 29, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 13:34, 14:03, 29, , Plastic Water Slabs, 1cm 
1cm Plastic Water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 13:56:16 2024, Felix Ulrich-Pur, WET measurement slabs, 31, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 14:48, 15:06, 18, , Plastic Water Slabs, 2cm 
2cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:10:35 2024, Felix Ulrich-Pur, WET measurement slabs, 33, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:24, 15:36, 12, , Plastic Water Slabs, 3cm 
3cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:12:46 2024, Felix Ulrich-Pur, WET measurement slabs, 35, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 15:53, 16:10, 17, , Plastic Water Slabs, 4cm 
4cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:15:46 2024, Felix Ulrich-Pur, WET measurement slabs, 37, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 16:28, 16:42, 12, , Plastic Water Slabs, 5cm 
5cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:17:57 2024, Felix Ulrich-Pur, WET measurement slabs, 39, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 17:00, 17:14, 13, , Dense Bone Slabs, 1cm 
1cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset