Entry  Sat Jun 8 20:05:27 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 4, TOF-Cal GSI, 175.3 MeV, Low Flux Medium, Proton, Good, 17:31, 17:54, , , ,  
500 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 170kHz on LGAD

TOF Calibration Curve
Entry  Sun Aug 25 12:23:44 2024, tb-crew, only base, 69, RD50-MPW4, 175.3 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 12:04:32, 25.08.2024 12:24:10, 19, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 69
Comment:
E-scan
Entry  Sat Dec 14 12:52:57 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 3, RaMon, 147.2 MeV/u, Low Flux Medium, Helium, Good, 06:32, 06:33, 1, , ,  
Mean rate per spill~ 2.5-4-5E5 p/s (online estimation without proper analysis)
Entry  Sat Dec 14 12:57:13 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux He test with RaMon, 10, RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 06:42, 06:42, 1, , ,  
Mean rate per spill~ 3..5e6 p/s (online estimation without proper analysis)
Entry  Sat Dec 14 13:28:57 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 20, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux Medium, Helium, Good, 10:33, 10:38, 5, , ,  
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

300kHz with Ramon and only 40kHz with TRB--> decision to go to low flux high was made
Entry  Sat Dec 14 13:31:49 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 21, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 10:41, 10:56, 15, , ,  
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

3.5MHz with Ramon and only 600kHz with TRB-52ps single channel res prae calib
Entry  Sat Dec 14 13:49:20 2024, Felix Ulrich-Pur, WET measurement slabs, 30, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 14:02, 14:45, 43, , Plastic Water Slabs, 1cm 
1cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:09:34 2024, Felix Ulrich-Pur, WET measurement slabs, 32, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 15:06, 15:19, 13, , Plastic Water Slabs, 2cm 
2cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:12:01 2024, Felix Ulrich-Pur, WET measurement slabs, 34, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 15:37, 15:48, 11, , Plastic Water Slabs, 3cm 
3cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:15:04 2024, Felix Ulrich-Pur, WET measurement slabs, 36, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 16:11, 16:23, 12, , Plastic Water Slabs, 4cm 
4cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:17:10 2024, Felix Ulrich-Pur, WET measurement slabs, 38, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 16:42, 16:55, 13, , Plastic Water Slabs, 5cm 
5cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:18:48 2024, Felix Ulrich-Pur, WET measurement slabs, 40, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 17:14, 17:28, 14, , Dense Bone Slabs, 1cm 
1cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:20:52 2024, Felix Ulrich-Pur, WET measurement slabs, 42, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 17:48, 18:00, 12, , Dense Bone Slabs, 2cm 
2cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:23:21 2024, Felix Ulrich-Pur, WET measurement slabs, 44, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:19, 18:33, 14, , Dense Bone Slabs, 2cm 
3cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:25:12 2024, Felix Ulrich-Pur, WET measurement slabs, 46, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 18:55, 19:11, 16, , Dense Bone Slabs, 4cm 
4cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Dec 14 15:27:08 2024, Felix Ulrich-Pur, WET measurement slabs, 48, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 19:30, 19:50, 20, , Dense Bone Slabs, 5cm 
5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset
Entry  Sat Jun 8 20:07:44 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs Calibrationcurve, 5, TOF-Cal GSI, 145.4 MeV, Low Flux Medium, Proton, Good, 17:55, 18:24, , , ,  
400 khz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 120kHz on LGAD

TOF Calibration Curve
Entry  Sat Jun 8 21:43:26 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 11, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 21:39, 21:48, , , ,  
1cm plastic water (in isocentre)
4 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 700 kHz on LGAD

WET measurement
Entry  Sat Jun 8 22:12:06 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 13, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 22:05, 22:34, , , ,  
2cm plastic water (in isocentre)
3.2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD

WET measurement
Entry  Sun Jun 9 00:07:17 2024, Felix Ulrich-Pur, TOF CAL HADES LGADs WET Messung Wasser, 18, TOF-Cal GSI, 145.4 MeV, Low Flux High, Proton, Good, 23:04, 23:20, , , ,  
4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 500 kHz on LGAD

WET measurement