ID Date Author Subject Run Numberdown DUT Beam Energy Rate Setting Particle Type Data t-Start t-Stop Duration_min Frontend Phantom Phantom thickness Text Attachments
  165   Sat Dec 14 13:40:47 2024 Felix Ulrich-Purthreshold and preamp tests26TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:3512:4914   TRB Setup: 260V bias and 250mA pre-amps,
threshold 10000 (changed threshold)

Diamond: 500mA, threshold 50
  
  96   Sun Jun 9 01:27:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen25TOF-Cal GSI194.3 MeVLow Flux HighProtonGood01:1601:30    3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  164   Sat Dec 14 13:39:15 2024 Felix Ulrich-PurEnergy vs TOF calibration25TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon63.3 MeV/uLow Flux HighHeliumGood12:0512:2318   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

380 kHz with Ramon and only 180kHz
  
  95   Sun Jun 9 01:26:56 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen24TOF-Cal GSI145.4 MeVLow Flux HighProtonGood01:0201:14    2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  163   Sat Dec 14 13:37:26 2024 Felix Ulrich-PurEnergy vs TOF calibration24TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon73.2 MeV/uLow Flux HighHeliumGood11:4212:0018   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

2MHz with Ramon and only 200kHz
  
  94   Sun Jun 9 01:25:26 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen23TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:3001:02    2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  162   Sat Dec 14 13:35:59 2024 Felix Ulrich-PurEnergy vs TOF calibration23TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon124.4 MeV/uLow Flux HighHeliumGood11:2411:3713   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

5MHz with Ramon and only 500kHz
  
  93   Sun Jun 9 01:22:48 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen22TOF-Cal GSI145.4 MeVLow Flux HighProtonGood00:1400:23    1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  92   Sun Jun 9 00:12:41 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Knochen21TOF-Cal GSI194.3 MeVLow Flux HighProtonGood00:0000:14    1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  160   Sat Dec 14 13:31:49 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux HighHeliumGood10:4110:5615   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3.5MHz with Ramon and only 600kHz
  
  161   Sat Dec 14 13:34:18 2024 Felix Ulrich-PurEnergy vs TOF calibration21TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon97.2MeV/uLow Flux HighHeliumGood10:5811:2325   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

3MHz with Ramon and only 300kHz
  
  91   Sun Jun 9 00:10:38 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser20TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:3100:00    5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  159   Sat Dec 14 13:28:57 2024 Felix Ulrich-PurEnergy vs TOF calibration20TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon147.2 MeV/uLow Flux MediumHeliumGood10:3310:385   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

300kHz with Ramon and only 40kHz
  
  73   Sat Jun 8 19:56:37 2024 Felix Ulrich-PurTOF CAL HADES LGADs Calibrationcurve2TOF-Cal GSI252.7 MeVLow Flux MediumProtonGood16:2916:47    1 Mhz on Ramon (after 5 Layers of Silicon
and close to second iso centre) and 350kHz
on LGAD
  
  141   Sat Dec 14 12:52:02 2024 Felix Ulrich-PurShift 23.11.24 low flux He test with RaMon2RaMon177.8 MeV/uLow Flux MediumHeliumGood06:3106:321   Mean rate per spill~ 6-8E5 p/s (online
estimation without proper analysis)
  
  90   Sun Jun 9 00:08:07 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser19TOF-Cal GSI194.3 MeVLow Flux HighProtonGood23:2023:30    5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  158   Sat Dec 14 13:26:29 2024 Felix Ulrich-PurEnergy vs TOF calibration19TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon177.8 MeV/uLow Flux MediumHeliumGood10:0810:2517   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000

750kHz with Ramon and only 160kHz
  
  89   Sun Jun 9 00:07:17 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser18TOF-Cal GSI145.4 MeVLow Flux HighProtonGood23:0423:20    4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  
  157   Sat Dec 14 13:16:33 2024 Felix Ulrich-PurEnergy vs TOF calibration +Alignment of DOGMA setup18TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon205.2 MeV/uLow Flux MediumHeliumGood09:4209:486   TRB Setup: 260V bias and 250mA pre-amps,
threshold 1000
  
  88   Sun Jun 9 00:06:01 2024 Felix Ulrich-PurTOF CAL HADES LGADs WET Messung Wasser17TOF-Cal GSI194.3 MeVLow Flux HighProtonGood22:5323:04    4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of
Silicon and close to second iso centre) and
  