Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 1 of 11  Not logged in ELOG logo
Entry  Sat Mar 30 09:53:41 2024, bp, ci, hh, RD50-MPW4, 1013, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:46:27, 30.03.2024 09:56:08, 9, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1013
Comment:
Entry  Sat Mar 30 15:51:21 2024, hh, mb, ps, 1st tests, 1036, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:43:53, 30.03.2024 15:53:47, 9, HV, ,  tjmonopix2.conf
automatic log for run 1036
Comment:
Entry  Sat Mar 30 09:36:22 2024, bp, ci, hh, RD50-MPW4, 1011, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 09:30:18, 30.03.2024 09:38:48, 8, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1011
Comment:
testing new tablealignment
Entry  Sat Mar 30 16:38:41 2024, hh, mb, ps, 1st tests, 1042, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:32:12, 30.03.2024 16:41:08, 8, HV, ,  tjmonopix2.conf
automatic log for run 1042
Comment: First good run
Entry  Sat Mar 30 09:27:33 2024, bp, ci, hh, RD50-MPW4, 1010, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 09:23:42, 30.03.2024 09:29:59, 6, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1010
Comment:
Entry  Sat Mar 30 09:42:55 2024, bp, ci, hh, RD50-MPW4, 1012, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:39:08, 30.03.2024 09:45:21, 6, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1012
Comment:
changed rate
Entry  Sat Mar 30 15:39:06 2024, hh, mb, ps, 1st tests, 1035, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:35:06, 30.03.2024 15:41:33, 6, HV, ,  tjmonopix2.conf
automatic log for run 1035

All four chips enabled now


Comment:
Entry  Sat Mar 30 16:24:39 2024, hh, mb, ps, 1st tests, 1041, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:20:34, 30.03.2024 16:27:05, 6, HV, ,  tjmonopix2.conf
automatic log for run 1041
Comment:
Entry  Sat Mar 30 17:00:53 2024, hh, mb, ps, 1st tests, 1044, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:57:08, 30.03.2024 17:03:20, 6, HV, ,  tjmonopix2.conf
automatic log for run 1044
Comment:
Entry  Sat Mar 30 19:44:43 2024, hh, mb, ps, High statistics, 1050, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:40:21, 30.03.2024 19:47:10, 6, HV, ,  tjmonopix2.conf
automatic log for run 1050
Comment:
Try with increased veto period of 20us (800)
Entry  Sun Aug 25 08:59:46 2024, tb-crew, VNFB scan, 54, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:53:16, 25.08.2024 09:00:13, 6, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 54
Comment:
vnfb = 20
Entry  Sat Dec 14 13:02:29 2024, Felix Ulrich-Pur, Shift 23.11.24 low flux Carbon test with RaMon (did not work), 15, RaMon, , Low Flux High, Carbon, Crap, 06:55, 07:01, 6, , ,  

Low flux carbon did not work

1µs EFE, 30s Extraction, Deg100
we tried different energies (402.MeV/u)-> 120 MeV/u, but unfortunately we did not get any beam

Entry  Sat Dec 14 13:16:33 2024, Felix Ulrich-Pur, Energy vs TOF calibration +Alignment of DOGMA setup, 18, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 09:42, 09:48, 6, , ,  

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

DOGMA setup had to be shifted manually to align it with the beam

Entry  Sat Dec 14 13:07:15 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 17, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux Medium, Helium, Good, 08:46, 09:42, 56, , ,  

before run, setups had to be aligned (first slab in slabholder was put in isocentre. However, in this run, no slab was used). Room was closed at 08:10

Beam->Nozzle-> Slabholder->TOF-CAL (TRB)-> DOGMA Setup(Diamond+LGADs)-> RaMon

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

measured 400kHz with Ramon and only 100kHz with LGADs (third LGAD) and 60kHz accepted trrigger rate

beam was shifted vertically by x? cm? (need to lookup again). So TRB setup was shifted with motors such that the He beam was hitting the centre of the LGADs

Entry  Sat Mar 30 11:55:55 2024, bp, ci, hh, useful datataking, 1023, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:06:49, 30.03.2024 11:58:22, 51, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1023
Comment:
Entry  Sat Mar 30 08:40:10 2024, bp, ci, hh, RD50-MPW4, 1008, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 08:37:03, 30.03.2024 08:42:37, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1008
Comment:
waiting for beam
Entry  Sat Mar 30 09:59:25 2024, bp, ci, hh, RD50-MPW4, 1014, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 09:56:17, 30.03.2024 10:01:51, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1014
Comment:
Entry  Sat Mar 30 10:05:09 2024, bp, ci, hh, RD50-MPW4, 1015, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:02:17, 30.03.2024 10:07:36, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1015
Comment:
changed rate
Entry  Sat Mar 30 10:10:57 2024, bp, ci, hh, RD50-MPW4, 1016, RD50-MPW4, 800 MeV, Low Flux Medium, Proton, Good, 30.03.2024 10:07:51, 30.03.2024 10:13:23, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1016
Comment:
changed rate
Entry  Sat Mar 30 10:39:45 2024, bp, ci, hh, RD50-MPW4, 1021, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 10:37:01, 30.03.2024 10:42:12, 5, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1021
Comment:
no tracker at start of run
ELOG V3.1.5-fc6679b