Entry  Sat Dec 14 13:28:57 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 20, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux Medium, Helium, Good, 10:33, 10:38, 5, , ,  

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

300kHz with Ramon and only 40kHz with TRB--> decision to go to low flux high was made

Entry  Sat Dec 14 15:28:46 2024, Felix Ulrich-Pur, threshold and preamp tests, 49, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 20:04, 20:09, 5, , ,  

TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (was too high)

Diamond: 900mA, threshold 1000 offset

3.5MHz Ramon

Entry  Sat Dec 14 13:49:20 2024, Felix Ulrich-Pur, WET measurement slabs, 30, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 14:02, 14:45, 43, , Plastic Water Slabs, 1cm 

1cm plastic water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

4MHz Ramon 500 kHz TRB

Entry  Sat Mar 30 07:00:10 2024, bp, ci, hh, RD50-MPW4, 1001, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 06:58:03, 30.03.2024 07:02:36, 4, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1001
Comment:
1st test runs
Entry  Sat Mar 30 15:31:41 2024, hh, mb, ps, 1st tests, 1034, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:29:49, 30.03.2024 15:34:08, 4, HV, ,  tjmonopix2.conf
automatic log for run 1034
Comment:
Entry  Sat Mar 30 16:50:35 2024, hh, mb, ps, 1st tests, 1043, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:48:39, 30.03.2024 16:53:01, 4, HV, ,  tjmonopix2.conf
automatic log for run 1043
Comment:
Entry  Sat Dec 14 15:50:19 2024, Felix Ulrich-Pur, LGAD+Diamond test with clinical carbon beam, 80, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 402MeV/u, , Carbon, Good, 05:15, 05:50, 35, , ,  

Carbon Deg10 (clinical rate)

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

Entry  Sat Dec 14 15:35:56 2024, Felix Ulrich-Pur, plastic mouse radiography, 55, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 22:12, 22:45, 33, , plastic mouse,  

pos x=25, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

Entry  Sat Mar 30 12:28:29 2024, bp, ci, hh, useful datataking, 1024, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:58:45, 30.03.2024 12:30:56, 32, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1024
Comment:
changed thr to 1V (not 100% sure, configure was not executed)
Entry  Sat Mar 30 13:28:15 2024, bp, ci, hh, useful datataking, 1026, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 12:58:02, 30.03.2024 13:30:42, 32, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1026
Comment:
changed thr to 0.98V
Entry  Sat Mar 30 10:34:27 2024, bp, ci, hh, RD50-MPW4, 1020, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 10:33:01, 30.03.2024 10:36:53, 3, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1020
Comment:
Entry  Sat Mar 30 11:04:10 2024, bp, ci, hh, RD50-MPW4, 1022, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 11:03:05, 30.03.2024 11:06:37, 3, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1022
Comment:
changed alignment again
Entry  Sat Mar 30 15:05:28 2024, hh, mb, ps, 1st tests, 1028, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:04:47, 30.03.2024 15:07:55, 3, HV, ,  tjmonopix2.conf
automatic log for run 1028
Comment:
Entry  Sat Mar 30 15:55:32 2024, hh, mb, ps, 1st tests, 1037, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:54:44, 30.03.2024 15:57:59, 3, HV, ,  tjmonopix2.conf
automatic log for run 1037
Comment:
Entry  Sat Mar 30 17:07:45 2024, hh, mb, ps, 1st tests, 1045, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 17:07:01, 30.03.2024 17:10:12, 3, HV, ,  tjmonopix2.conf
automatic log for run 1045
Comment:
Entry  Sat Mar 30 20:51:31 2024, hh, mb, ps, High statistics, 1054, TJ-Monopix2, 800 MeV, Low Flux High, Proton, Unknown, 30.03.2024 20:50:53, 30.03.2024 20:53:58, 3, HV, ,  tjmonopix2.conf
automatic log for run 1054
Comment:
Litle high settings run
Entry  Sat Dec 14 13:46:11 2024, Felix Ulrich-Pur, WET measurement slabs, 29, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 205.2 MeV/u, Low Flux High, Helium, Good, 13:34, 14:03, 29, , Plastic Water Slabs, 1cm 

1cm Plastic Water

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)

Diamond: 900mA, threshold 1000 offset

DOGMA lost DiRICH after restarting Wave (happened several times)

Entry  Sat Mar 30 20:13:29 2024, hh, mb, ps, High statistics, 1051, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:48:36, 30.03.2024 20:15:55, 27, HV, ,  tjmonopix2.conf
automatic log for run 1051
Comment:
Try with increased veto period of 20us (800)
Entry  Sun Aug 25 08:10:54 2024, tb-crew, Piggy test, 51, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 07:45:15, 25.08.2024 08:11:20, 26, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 51
Comment:
stuck again?
Entry  Sat Dec 14 13:34:18 2024, Felix Ulrich-Pur, Energy vs TOF calibration, 21, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 10:58, 11:23, 25, , ,  

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

3MHz with Ramon and only 300kHz with TRB-44ps single channel res prae calib