Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  Testbeams at MedAustron in 2024, Page 3 of 11  Not logged in ELOG logo
Entry  Sat Dec 14 15:47:29 2024, Felix Ulrich-Pur, plastic mouse radiography, 73, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 03:20, 03:55, 25, , plastic mouse,  

pos x=-175, posy=-175

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

Entry  Sat Mar 30 12:54:24 2024, bp, ci, hh, useful datataking, 1025, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Good, 30.03.2024 12:32:27, 30.03.2024 12:56:51, 24, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1025
Comment:
changed thr to 0.95V
Entry  Sat Mar 30 19:24:57 2024, hh, mb, ps, High statistics, 1048, TJ-Monopix2, 800 MeV, Low Flux Medium, Proton, Unknown, 30.03.2024 19:02:52, 30.03.2024 19:27:24, 24, HV, ,  tjmonopix2.conf
automatic log for run 1048
Comment:
Run with medium settings
Entry  Sun Aug 25 07:43:36 2024, tb-crew, Piggy test, 50, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 07:19:46, 25.08.2024 07:44:03, 24, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 50
Comment:
Entry  Sat Dec 14 13:42:52 2024, Felix Ulrich-Pur, threshold and preamp tests , 27, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 63.3 MeV/u, Low Flux High, Helium, Good, 12:52, 13:16, 24, , ,  

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000 (changed threshold)

Diamond: 900mA, threshold 50

Entry  Sat Dec 14 15:33:35 2024, Felix Ulrich-Pur, plastic mouse radiography, 53, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:33, 21:57, 24, , plastic mouse,  

run 52 was crap

pos x=175, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

Entry  Sat Mar 30 09:03:54 2024, bp, ci, hh, RD50-MPW4, 1009, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Crap, 30.03.2024 08:43:22, 30.03.2024 09:06:20, 22, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1009
Comment:
waiting for beam
Performing MTS restart
Entry  Sun Aug 25 08:33:56 2024, tb-crew, Piggy test, 52, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 08:11:40, 25.08.2024 08:34:23, 22, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 52
Comment:
Entry  Sun Aug 25 12:00:00 2024, tb-crew, only base, 68, RD50-MPW4, 252.7 MeV, Low Flux Very Low, Proton, Unknown, 25.08.2024 11:37:41, 25.08.2024 12:00:27, 22, Normal, ,  peary_config.cfgmatrix_mpw4_base.txtmatrix_mpw4_piggy.txtmpw4.conf
automatic log for run 68
Comment:
E-scan
Entry  Sat Dec 14 15:34:50 2024, Felix Ulrich-Pur, plastic mouse radiography, 54, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 21:58, 22:10, 22, , plastic mouse,  

pos x=100, posy=0

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

Entry  Sat Mar 30 17:31:59 2024, hh, mb, ps, High statistics, 1046, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 17:13:09, 30.03.2024 17:34:25, 21, HV, ,  tjmonopix2.conftestbench_AB.yamltestbench_CD.yaml
automatic log for run 1046
Comment:
High statistics run, from now we fix the geometry

Veto: 7us (100, so 7 us is handshake time)
Entry  Sat Mar 30 07:44:15 2024, bp, ci, hh, RD50-MPW4, 1005, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Unknown, 30.03.2024 07:25:51, 30.03.2024 07:46:41, 20, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1005
Comment:
beautifully correlated Big grin
Entry  Sat Mar 30 08:21:04 2024, bp, ci, hh, RD50-MPW4, 1007, RD50-MPW4, 800 MeV, Low Flux Very Low, Proton, Good, 30.03.2024 08:02:46, 30.03.2024 08:23:30, 20, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1007
Comment:
waiting for eam
Entry  Sat Dec 14 15:27:08 2024, Felix Ulrich-Pur, WET measurement slabs, 48, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 147.2 MeV/u, Low Flux High, Helium, Good, 19:30, 19:50, 20, , Dense Bone Slabs, 5cm 

5cm dense bone

TRB Setup: 260V bias and 250mA pre-amps, threshold 1000

Diamond: 900mA, threshold 1000 offset

1.5MHz Ramon

Wave crashes if 1 TDC disappears in dog d, DABC is still running

Entry  Sat Dec 14 15:45:36 2024, Felix Ulrich-Pur, plastic mouse radiography, 70, TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon, 97.2MeV/u, Low Flux High, Helium, Good, 02:25, 02:45, 20, , plastic mouse,  

pos x=-25, posy=75

TRB Setup: 260V bias and 250mA pre-amps, threshold 5000

Diamond: 900mA, threshold 1000 offset

beam was shortly off at 02:30

Entry  Sat Mar 30 10:25:55 2024, bp, ci, hh, RD50-MPW4, 1018, RD50-MPW4, 800 MeV, Low Flux Low, Proton, Crap, 30.03.2024 10:26:17, 30.03.2024 10:28:21, 2, Normal, ,  peary_config.cfgmatrix_mpw4.txtmpw4.conf
automatic log for run 1018
Comment:
Entry  Sat Mar 30 15:08:33 2024, hh, mb, ps, 1st tests, 1029, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:08:26, 30.03.2024 15:11:00, 2, HV, ,  tjmonopix2.conf
automatic log for run 1029
Comment:
Entry  Sat Mar 30 15:18:29 2024, hh, mb, ps, 1st tests, 1030, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:18:21, 30.03.2024 15:20:55, 2, HV, ,  tjmonopix2.conf
automatic log for run 1030
Comment:
Entry  Sat Mar 30 15:24:44 2024, hh, mb, ps, 1st tests, 1033, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 15:25:06, 30.03.2024 15:27:10, 2, HV, ,  tjmonopix2.conf
automatic log for run 1033
Comment:
Entry  Sat Mar 30 16:03:35 2024, hh, mb, ps, 1st tests, 1038, TJ-Monopix2, 800 MeV, Low Flux Low, Proton, Unknown, 30.03.2024 16:03:18, 30.03.2024 16:06:01, 2, HV, ,  tjmonopix2.conf
automatic log for run 1038
Comment:
ELOG V3.1.5-fc6679b