ID Date Author Subject Run Number DUTdown Beam Energy Rate Setting Particle Type Events Data t-Start t-Stop Duration_min Frontend
  2   Sat Feb 18 21:42:06 2023   674common800Low Flux LowProton0Unknown18.02.2023 21:41:5718.02.2023 21:42:05  
automatic log for run 674
  3   Sat Feb 18 22:14:32 2023 BP_PSstart_test10000common8005kHzProton0Unknown18.02.2023 22:12:4418.02.2023 22:14:32  
automatic log for run 10000
  5   Sat Feb 18 22:18:39 2023 BP_PSBeam common8005kHzProton Unknown    
Status 22:19, waiting for beam, vakuum Problem in der Quelle
  6   Sat Feb 18 22:26:47 2023 BP_PSBeam common8005kHzProton Unknown    
Status: Beam bekommen um 22:23
  7   Sat Feb 18 22:30:02 2023 BP_PSBeam2common8005kHzProton521924Unknown18.02.2023 22:23:2618.02.2023 22:30:02  
automatic log for run 2
  8   Sat Feb 18 22:32:10 2023 BP_PSBeam3common8005kHzProton67592Unknown18.02.2023 22:31:0318.02.2023 22:32:09  
automatic log for run 3
  9   Sat Feb 18 22:37:45 2023 BP_PSINFO common8005kHzProton Unknown    
z positions:
DSSD1: 0mm
DSSD2: 48mm
MPW3: 35mm
DSSD3: 127mm
DSSD4: 50mm
All positions relativ to previous position!
  10   Sat Feb 18 22:46:28 2023 BP_PSbeam4common8005kHzProton1097321Unknown18.02.2023 22:32:1618.02.2023 22:46:27  
automatic log for run 4
  11   Sat Feb 18 22:59:14 2023 BP_PSbeam5common8005kHzProton5196863Unknown18.02.2023 22:46:3618.02.2023 22:59:14  
automatic log for run 5
  12   Sat Feb 18 23:00:02 2023 BP_PSbeam6common8005kHzProton119056Unknown18.02.2023 22:59:2618.02.2023 23:00:02  
automatic log for run 6
  13   Sat Feb 18 23:31:12 2023 BP_PSbeam7common8005kHzProton16617889Unknown18.02.2023 23:00:0918.02.2023 23:31:12  
automatic log for run 7
  14   Sat Feb 18 23:33:07 2023 BP_PSbeam8common8005kHzProton625617Unknown18.02.2023 23:31:4318.02.2023 23:33:07  
automatic log for run 8
  15   Sat Feb 18 23:38:40 2023 BP_PSbeam9common8005kHzProton2714936Unknown18.02.2023 23:33:1518.02.2023 23:38:40  
automatic log for run 9
  16   Sat Feb 18 23:58:44 2023 BP_PSINFO common8005kHzProton Unknown    
Moved DUT 4mm before run 9
  17   Sun Feb 19 00:07:33 2023 BP_PSbeam10common8005kHzProton6238221Unknown18.02.2023 23:55:0319.02.2023 00:07:33  
automatic log for run 10
  18   Sun Feb 19 00:21:20 2023 BP_PSbeam11common8005kHzProton7464335Unknown19.02.2023 00:07:4219.02.2023 00:21:20  
automatic log for run 11
  19   Sun Feb 19 00:23:30 2023 BP_PSbeam12common8005kHzProton786240Unknown19.02.2023 00:21:4519.02.2023 00:23:30  
automatic log for run 12
  20   Sun Feb 19 00:25:54 2023 BP_PSbeam13common8005kHzProton798582Unknown19.02.2023 00:24:0619.02.2023 00:25:54  
automatic log for run 13
  21   Sun Feb 19 00:32:49 2023 BP_PSbeam14common8005kHzProton3313269Unknown19.02.2023 00:26:0819.02.2023 00:32:49  
automatic log for run 14
  22   Sun Feb 19 00:35:07 2023 BP_PSbeam15common8005kHzProton965511Unknown19.02.2023 00:32:5819.02.2023 00:35:07  
automatic log for run 15
  23   Sun Feb 19 00:38:25 2023 BP_PSbeam16common8005kHzProton1180283Unknown19.02.2023 00:35:5119.02.2023 00:38:25  
automatic log for run 16
  24   Sun Feb 19 00:41:55 2023 BP_PSbeam17common8005kHzProton1385903Unknown19.02.2023 00:39:1219.02.2023 00:41:55  
automatic log for run 17
  25   Sun Feb 19 00:42:31 2023 BP_PSbeam18common8005kHzProton99203Unknown19.02.2023 00:42:0019.02.2023 00:42:31  
automatic log for run 18
  26   Sun Feb 19 00:47:46 2023 BP_PSbeam19common8005kHzProton2516208Unknown19.02.2023 00:42:4319.02.2023 00:47:46  
automatic log for run 19
  27   Sun Feb 19 00:51:47 2023 BP_PSbeam20common8005kHzProton1834173Unknown19.02.2023 00:47:5219.02.2023 00:51:47  
automatic log for run 20
  28   Sun Feb 19 01:23:54 2023 BP_PSbeam21common8005kHzProton12411867Unknown19.02.2023 00:59:4719.02.2023 01:23:53  
automatic log for run 21
  29   Sun Feb 19 01:31:35 2023 BP_PSbeam22common8005kHzProton3527769Unknown19.02.2023 01:23:5819.02.2023 01:31:34  
automatic log for run 22
  30   Sun Feb 19 01:35:10 2023 BP_PSbeam23common8005kHzProton1588792Unknown19.02.2023 01:31:4019.02.2023 01:35:10  
automatic log for run 23
  31   Sun Feb 19 01:56:49 2023 BP_PSbeam24common8005kHzProton9755033Unknown19.02.2023 01:35:2619.02.2023 01:56:49  
automatic log for run 24
  32   Sun Feb 19 01:58:21 2023 BP_PSbeam25common8005kHzProton441973Unknown19.02.2023 01:57:0219.02.2023 01:58:21  
automatic log for run 25
  33   Sun Feb 19 02:02:47 2023 BP_PSbeam26common8005kHzProton54382Unknown19.02.2023 02:02:2919.02.2023 02:02:47  
automatic log for run 26
  34   Sun Feb 19 02:05:04 2023 BP_PSINFO common8005kHzProton Unknown    
change TH before run 26, chip was getting noisy to 1,15V
Before it was at 1,08
  35   Sun Feb 19 02:05:35 2023 BP_PSbeam27common8005kHzProton693679Unknown19.02.2023 02:03:5819.02.2023 02:05:34  
automatic log for run 27
  36   Sun Feb 19 02:08:06 2023 BP_PSbeam28common8005kHzProton752984Unknown19.02.2023 02:06:3019.02.2023 02:08:06  
automatic log for run 28
  37   Sun Feb 19 02:08:34 2023 BP_PSINFO common8005kHzProton Unknown    
TH change again before run 27, new TH= 1.1
  38   Sun Feb 19 02:16:56 2023 BP_PSbeam29common8005kHzProton232363Unknown19.02.2023 02:15:1519.02.2023 02:16:56  
automatic log for run 29
  39   Sun Feb 19 02:47:40 2023 BP_PSbeam30common8005kHzProton10864033Unknown19.02.2023 02:22:4719.02.2023 02:47:40  
automatic log for run 30
  40   Sun Feb 19 03:03:38 2023 BP_PSbeam31common8005kHzProton75989Unknown19.02.2023 03:03:2519.02.2023 03:03:38  
automatic log for run 31
  90   Fri May 5 16:00:29 2023   45common800Low Flux LowProton104700Unknown05.05.2023 15:58:2305.05.2023 15:59:40 Normal
automatic log for run 45
  91   Fri May 5 17:53:22 2023   47common800Low Flux LowProton85154Unknown05.05.2023 17:51:1905.05.2023 17:52:33 Normal
automatic log for run 47
  112   Sat May 6 10:43:57 2023 cibpdata taking common800200kHzProton Unknown   Normal
adjusted table in height by ~-2mm
  144   Sat May 6 18:52:10 2023   90common800Low Flux LowProton36435245Good06.05.2023 18:01:4706.05.2023 18:51:18 Normal
automatic log for run 90
Comment:
  145   Sat May 6 18:57:10 2023   91common800200kHzProton2299723Good06.05.2023 18:52:5006.05.2023 18:56:18 Normal
automatic log for run 91
Comment:
VCLIP 250
  146   Sat May 6 18:59:59 2023   92common800200kHzProton1406012Good06.05.2023 18:57:0306.05.2023 18:59:07 Normal
automatic log for run 92
Comment:
VCLIP 240
  147   Sat May 6 19:02:54 2023   93common800200kHzProton1265105Good06.05.2023 19:00:0506.05.2023 19:02:02 Normal
automatic log for run 93
Comment:
VCLIP 230
  148   Sat May 6 19:05:40 2023   94common800200kHzProton1402560Good06.05.2023 19:02:4506.05.2023 19:04:48 Normal
automatic log for run 94
Comment:
VCLIP 220
  149   Sat May 6 19:08:08 2023   95common800200kHzProton1124393Good06.05.2023 19:05:3806.05.2023 19:07:16 Normal
automatic log for run 95
Comment:
VCLIP 210
  150   Sat May 6 19:10:48 2023   96common800200kHzProton1229453Good06.05.2023 19:08:0106.05.2023 19:09:56 Normal
automatic log for run 96
Comment:
VCLIP 200
  151   Sat May 6 19:13:42 2023   97common800200kHzProton0Crap06.05.2023 19:10:4606.05.2023 19:12:50 Normal
automatic log for run 97
Comment:
VCLIP 190
  152   Sat May 6 19:42:31 2023   98common800200kHzProton314807Crap06.05.2023 19:20:4306.05.2023 19:41:39 Normal
automatic log for run 98
Comment:
VCLIP 190
  153   Sat May 6 19:45:11 2023   99common800200kHzProton1250630Good06.05.2023 19:42:2806.05.2023 19:44:19 Normal
automatic log for run 99
Comment:
VCLIP 190
  154   Sat May 6 19:47:57 2023   100common800200kHzProton1641664Good06.05.2023 19:44:5506.05.2023 19:47:05 Normal
automatic log for run 100
Comment:
VCLIP 180
  155   Sat May 6 19:58:32 2023   101common800200kHzProton8565587Good06.05.2023 19:47:4706.05.2023 19:57:39 Normal
automatic log for run 101
Comment:
Testrun for alignment (10min)
  156   Sat May 6 20:17:17 2023   102common800200kHzProton13915399Good06.05.2023 19:58:0906.05.2023 20:16:24 Normal
automatic log for run 102
Comment:
Testrun for alignment (coffee break)
  157   Sat May 6 20:20:06 2023   103common800200kHzProton1382069Good06.05.2023 20:17:1406.05.2023 20:19:14 Normal
automatic log for run 103
Comment:
VCLIP 170
  158   Sat May 6 20:22:35 2023   104common800200kHzProton1157446Good06.05.2023 20:20:0406.05.2023 20:21:43 Normal
automatic log for run 104
Comment:
VCLIP 175
  159   Sat May 6 20:25:25 2023   105common800200kHzProton1596079Good06.05.2023 20:22:1506.05.2023 20:24:33 Normal
automatic log for run 105
Comment:
VCLIP 160
  160   Sat May 6 20:28:13 2023   106common800200kHzProton1534798Good06.05.2023 20:25:0606.05.2023 20:27:21 Normal
automatic log for run 106
Comment:
VCLIP 155
  161   Sat May 6 20:31:25 2023   107common800200kHzProton1600329Good06.05.2023 20:28:1006.05.2023 20:30:33 Normal
automatic log for run 107
Comment:
VCLIP 150
  162   Sat May 6 20:34:22 2023   108common800200kHzProton1552623Good06.05.2023 20:31:1206.05.2023 20:33:30 Normal
automatic log for run 108
Comment:
VCLIP 145
  163   Sat May 6 20:37:12 2023   109common800200kHzProton1450927Good06.05.2023 20:34:1106.05.2023 20:36:20 Normal
automatic log for run 109
Comment:
VCLIP 140
  164   Sat May 6 20:42:17 2023   110common800200kHzProton3100010Good06.05.2023 20:36:5906.05.2023 20:41:24 Normal
automatic log for run 110
Comment:
VCLIP 135
  165   Sat May 6 20:56:58 2023   111common800Low Flux LowProton7293463Unknown06.05.2023 20:46:1306.05.2023 20:56:06 Normal
automatic log for run 111
Comment:
VCLIP 130 (first one run with data since a while ago, also longer for alignment)
  166   Sat May 6 20:59:29 2023   112common800200kHzProton1176044Good06.05.2023 20:56:5906.05.2023 20:58:36 Normal
automatic log for run 112
Comment:
VCLIP 100
  167   Sat May 6 21:01:39 2023   113common800200kHzProton999866Good06.05.2023 20:59:2206.05.2023 21:00:47 Normal
automatic log for run 113
Comment:
VCLIP 110
  168   Sat May 6 21:04:50 2023   114common800200kHzProton349320Good06.05.2023 21:03:2406.05.2023 21:03:58 Normal
automatic log for run 114
Comment:
VCLIP 200
  169   Sat May 6 21:09:10 2023   115common800200kHzProton1634138Good06.05.2023 21:06:0406.05.2023 21:08:17 Normal
automatic log for run 115
Comment:
VCLIP 200
  170   Sat May 6 21:10:23 2023   116common800200kHzProton145044Good06.05.2023 21:09:1006.05.2023 21:09:31 Normal
automatic log for run 116
Comment:
VCLIP 200
  171   Sat May 6 21:13:46 2023   117common800200kHzProton1670098Good06.05.2023 21:10:3206.05.2023 21:12:54 Normal
automatic log for run 117
Comment:
VCLIP 170
  172   Sat May 6 21:17:01 2023   118common800200kHzProton1379570Good06.05.2023 21:14:0906.05.2023 21:16:09 Normal
automatic log for run 118
Comment:
VCLIP 180
  173   Sat May 6 21:30:02 2023   119common800200kHzProton7663968Good06.05.2023 21:18:3206.05.2023 21:29:09 Normal
automatic log for run 119
Comment:
Alignment run with default settings
  174   Sat May 6 21:33:17 2023   120common800200kHzProton1543284Good06.05.2023 21:30:0806.05.2023 21:32:25 Normal
automatic log for run 120
Comment:
VCLIP 220
  175   Sat May 6 21:38:19 2023   121common800200kHzProton2732840Good06.05.2023 21:33:3306.05.2023 21:37:27 Normal
automatic log for run 121
Comment:
VCLIP?
  176   Sat May 6 21:39:32 2023   122common800200kHzProton121791Crap06.05.2023 21:38:2206.05.2023 21:38:40 Normal
automatic log for run 122
Comment:
ICAN 20
  177   Sat May 6 21:46:56 2023   123common8005kHzProton2987729Unknown06.05.2023 21:41:3706.05.2023 21:46:04 Normal
automatic log for run 123
Comment:
  178   Sat May 6 21:58:14 2023   124common8005kHzProton306082Good06.05.2023 21:50:0406.05.2023 21:57:21 Normal
automatic log for run 124
Comment:
Alignment run low flux
  41   Sun Feb 19 03:09:26 2023 BP_PSbeam32RD50-MPW3800200kHzProton2391117Unknown19.02.2023 03:03:4719.02.2023 03:09:26  
automatic log for run 32
sieht gut aus, hinten ist sensor noisy!
  42   Sun Feb 19 03:28:55 2023  beam33RD50-MPW3800200kHzProton7084523Unknown19.02.2023 03:13:0919.02.2023 03:28:55  
automatic log for run 33
  43   Sun Feb 19 03:35:01 2023  beam34RD50-MPW3800200kHzProton2514361Unknown19.02.2023 03:29:0019.02.2023 03:35:01  
automatic log for run 34
  44   Sun Feb 19 04:01:13 2023 BP_PSbeam35RD50-MPW3800200kHzProton11489478Unknown19.02.2023 03:35:1219.02.2023 04:01:13  
automatic log for run 35
  45   Sun Feb 19 04:07:11 2023 BP_PSbeam36RD50-MPW3800200kHzProton342134Unknown19.02.2023 04:05:4419.02.2023 04:07:11  
automatic log for run 36
  46   Sun Feb 19 04:08:21 2023 BP_PSbeam37RD50-MPW3800200kHzProton167488Unknown19.02.2023 04:07:3419.02.2023 04:08:21  
automatic log for run 37
  47   Sun Feb 19 04:10:47 2023 BP_PSbeam38RD50-MPW3800200kHzProton646081Unknown19.02.2023 04:09:0219.02.2023 04:10:47  
automatic log for run 38
  48   Sun Feb 19 04:20:21 2023 BP_PSbeam39RD50-MPW3800200kHzProton4127604Unknown19.02.2023 04:10:5419.02.2023 04:20:21  
automatic log for run 39
  49   Sun Feb 19 04:22:26 2023 BP_PSbeam40RD50-MPW3800200kHzProton656458Unknown19.02.2023 04:20:2819.02.2023 04:22:25  
automatic log for run 40
edit: adjusted alignment of whole tracker (in hope for better rate)
  50   Sun Feb 19 04:30:13 2023 BP_PSbeam41RD50-MPW3800200kHzProton200504Unknown19.02.2023 04:28:5219.02.2023 04:30:13  
automatic log for run 41
edit: adjusted alignment of whole tracker (in hope for better rate)
  51   Sun Feb 19 04:36:56 2023 BP_PSbeam42RD50-MPW3800200kHzProton536729Unknown19.02.2023 04:34:5319.02.2023 04:36:55  
automatic log for run 42
edit: adjusted alignment of whole tracker (in hope for better rate)
  52   Sun Feb 19 05:30:14 2023 BP_PSbeam43RD50-MPW3800200kHzProton23353199Good19.02.2023 04:37:2219.02.2023 05:30:14  
automatic log for run 43
  53   Sun Feb 19 06:03:02 2023 BP_PSbeam44RD50-MPW3800200kHzProton13755631Unknown19.02.2023 05:30:2319.02.2023 06:03:02  
automatic log for run 44
  54   Sun Feb 19 06:39:15 2023 BP_PSbeam45RD50-MPW3800200kHzProton15494364Unknown19.02.2023 06:03:1219.02.2023 06:39:15  
automatic log for run 45
  93   Sat May 6 07:49:04 2023 cibp1st tests49RD50-MPW3800200kHzProton692561Unknown06.05.2023 07:34:2006.05.2023 07:48:13 Normal
automatic log for run 49
Comment:

beam profile tracker -> attachement 1
  94   Sat May 6 08:08:45 2023 cibp1st tests50RD50-MPW3800200kHzProton868396Unknown06.05.2023 07:51:2206.05.2023 08:07:55 Normal
automatic log for run 50
Comment:
testing for the moment
might (not) be useful data
  95   Sat May 6 08:09:15 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normal
changed MPX2 trigger veto from 625us -> 100us veto length
  96   Sat May 6 08:11:28 2023 cibp1st tests51RD50-MPW3800200kHzProton1Unknown06.05.2023 08:10:2606.05.2023 08:10:38 Normal
automatic log for run 51
Comment:
trying to run mpx2
  97   Sat May 6 08:45:07 2023 cibp1st tests52RD50-MPW3800200kHzProton8992077Unknown06.05.2023 08:12:3106.05.2023 08:44:16 Normal
automatic log for run 52
Comment:
trying to run mpx2 without trigger loss
  98   Sat May 6 08:59:49 2023 cibp1st tests53RD50-MPW3800200kHzProton1Unknown06.05.2023 08:57:0506.05.2023 08:58:59 Normal
automatic log for run 53
Comment:
trying to run mpx2 without trigger loss
  99   Sat May 6 09:02:17 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normal
moved whole setup by ~2mm in x
  100   Sat May 6 09:04:46 2023 cibp1st tests RD50-MPW3800200kHzProton Unknown   Normal
apperently wrong direction, adjusting again
moved 2mm (from origin) in other direction
  101   Sat May 6 09:07:40 2023 cibp1st tests54RD50-MPW3800200kHzProton926384Unknown06.05.2023 09:01:5206.05.2023 09:06:49 Normal
automatic log for run 54
Comment:
moved sensors 2mm towards LCR1 (+y for tracker)
apperently wrong direction, adjusting again
  102   Sat May 6 09:17:42 2023 cibpdata-taking55RD50-MPW3800200kHzProton1Unknown06.05.2023 09:16:1906.05.2023 09:16:52 Normal
automatic log for run 55
Comment:
sensors moved 2mm in -y (away from LCR1, towards rack)
  103   Sat May 6 09:24:21 2023 cibpdata-taking56RD50-MPW3800200kHzProton1243318Unknown06.05.2023 09:18:2406.05.2023 09:23:30 Normal
automatic log for run 56
Comment:
  104   Sat May 6 09:31:55 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
alignment of MPW3 seems better
  105   Sat May 6 09:41:50 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed rate to 5kHz
  107   Sat May 6 09:50:52 2023 cibpdata-taking57RD50-MPW38005kHzProton2315658Unknown06.05.2023 09:24:5806.05.2023 09:50:02 Normal
automatic log for run 57
Comment:
  108   Sat May 6 09:51:57 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
changed mpx2 settings by max
  109   Sat May 6 10:01:28 2023 cibpdata-taking58RD50-MPW38005kHzProton931155Unknown06.05.2023 09:51:3206.05.2023 10:00:38 Normal
automatic log for run 58
Comment:
  110   Sat May 6 10:08:09 2023 cibpdata-taking RD50-MPW38005kHzProton Unknown   Normal
no MPX2 data atm, problem with datacollector
  111   Sat May 6 10:12:23 2023 cibpdata-taking59RD50-MPW38005kHzProton1039920Unknown06.05.2023 10:01:2406.05.2023 10:11:32 Normal
automatic log for run 59
Comment:
  113   Sat May 6 11:04:28 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
No beam since 30 min
Operator: "spills get rejected by ..."
  114   Sat May 6 11:13:04 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
MPS (whatever) restart necessary
No beam for another ~ 20 -30 min
  115   Sat May 6 11:21:47 2023 cibpdata taking60RD50-MPW3800200kHzProton193381Unknown06.05.2023 10:46:4406.05.2023 11:20:56 Normal
automatic log for run 60
Comment:
  116   Sat May 6 12:57:47 2023 cibpdata taking61RD50-MPW3800200kHzProton0Unknown06.05.2023 12:56:3406.05.2023 12:56:56 Normal
automatic log for run 61
Comment:
  117   Sat May 6 13:04:06 2023 cibpdata taking RD50-MPW3800200kHzProton Unknown   Normal
beam is back Smile
  118   Sat May 6 13:13:05 2023 cibpdata taking62RD50-MPW3800200kHzProton1336043Unknown06.05.2023 12:59:3306.05.2023 13:12:14 Normal
automatic log for run 62
Comment:
Sensors now 2 mm lower to increase hit rate on MPW3 (was slightly too high)
  119   Sat May 6 13:21:02 2023 cibpdata taking63RD50-MPW3800200kHzProton566713Unknown06.05.2023 13:12:3806.05.2023 13:20:11 Normal
automatic log for run 63
Comment:
  120   Sat May 6 13:44:59 2023 cibpmbpsdata taking65RD50-MPW3800200kHzProton12617213Unknown06.05.2023 13:26:4206.05.2023 13:44:08 Normal
automatic log for run 65
Comment:
  121   Sat May 6 14:07:32 2023 cibpmbpsdata taking66RD50-MPW3800200kHzProton14540161Unknown06.05.2023 13:45:5406.05.2023 14:06:41 Normal
automatic log for run 66
Comment:
  123   Sat May 6 14:27:55 2023 cibpmbpsdata taking67RD50-MPW3252.7Low Flux MediumProton8797699Good06.05.2023 14:09:0806.05.2023 14:27:04 Normal Casc
automatic log for run 67
Comment:
  124   Sat May 6 15:42:54 2023 TB crewMPX2 MPW3 TB70RD50-MPW3800200kHzProton1284521Good06.05.2023 15:40:1006.05.2023 15:42:02 Normal Casc
automatic log for run 70
Comment:
  125   Sat May 6 15:47:03 2023 TB crewMPX2 MPW3 TB71RD50-MPW3800200kHzProton2164383Good06.05.2023 15:42:3006.05.2023 15:46:11 Normal Casc
automatic log for run 71
Comment:
  126   Sat May 6 15:50:05 2023 TB crewMPX2 MPW3 TB72RD50-MPW3800200kHzProton913881Good06.05.2023 15:47:5406.05.2023 15:49:13 Normal Casc
automatic log for run 72
Comment:
  127   Sat May 6 15:58:49 2023 TB crewMPX2 MPW3 TB73RD50-MPW3800200kHzProton3897223Good06.05.2023 15:52:1906.05.2023 15:57:58 Normal Casc
automatic log for run 73
Comment:
  128   Sat May 6 16:10:24 2023 TB crewMPX2 MPW3 TB74RD50-MPW3252.7Low Flux MediumProton4400593Good06.05.2023 16:03:5206.05.2023 16:09:32 Normal Casc
automatic log for run 74
Comment:
  129   Sat May 6 16:18:11 2023 TB crewMPX2 MPW3 TB75RD50-MPW3252.7Low Flux MediumProton5062608Good06.05.2023 16:10:4706.05.2023 16:17:20 Normal Casc
automatic log for run 75
Comment:
VCLIP 150
  130   Sat May 6 16:25:27 2023 TB crewMPX2 MPW3 TB76RD50-MPW3194.3Low Flux MediumProton5138021Good06.05.2023 16:18:2906.05.2023 16:24:35 Normal Casc
automatic log for run 76
Comment:
VCLIP 150
  131   Sat May 6 16:31:11 2023 TB crewMPX2 MPW3 TB77RD50-MPW3194.3Low Flux MediumProton4293139Good06.05.2023 16:25:2306.05.2023 16:30:18 Normal Casc
automatic log for run 77
Comment:
  132   Sat May 6 16:37:40 2023 TB crewMPX2 MPW3 TB78RD50-MPW3175.3Low Flux MediumProton4053764Good06.05.2023 16:31:3306.05.2023 16:36:48 Normal Casc
automatic log for run 78
Comment:
  133   Sat May 6 16:43:35 2023 TB crewMPX2 MPW3 TB79RD50-MPW3175.3Low Flux MediumProton4106269Good06.05.2023 16:37:5306.05.2023 16:42:43 Normal Casc
automatic log for run 79
Comment:
VCLIP 150
  134   Sat May 6 16:50:23 2023 TB crewMPX2 MPW3 TB80RD50-MPW3145.4Low Flux MediumProton4152629Good06.05.2023 16:43:1206.05.2023 16:49:31 Normal Casc
automatic log for run 80
Comment:
VCLIP 150
  135   Sat May 6 16:56:48 2023 TB crewMPX2 MPW3 TB81RD50-MPW3145.4Low Flux MediumProton959659Good06.05.2023 16:50:0606.05.2023 16:55:56 Normal Casc
automatic log for run 81
Comment:
  136   Sat May 6 16:59:03 2023 TB crewMPX2 MPW3 TB82RD50-MPW3100.4Low Flux MediumProton0Crap06.05.2023 16:57:2006.05.2023 16:58:11 Normal Casc
automatic log for run 82
Comment:
  137   Sat May 6 17:08:40 2023 TB crewMPX2 MPW3 TB83RD50-MPW3100.4Low Flux MediumProton3272369Good06.05.2023 17:02:2906.05.2023 17:07:49 Normal Casc
automatic log for run 83
Comment:
  138   Sat May 6 17:16:33 2023 TB crewMPX2 MPW3 TB84RD50-MPW3100.4Low Flux MediumProton4830327Good06.05.2023 17:08:2406.05.2023 17:15:41 Normal Casc
automatic log for run 84
Comment:
VCLIP 150
  139   Sat May 6 17:22:40 2023 TB crewMPX2 MPW3 TB85RD50-MPW383Low Flux MediumProton2779147Good06.05.2023 17:16:2506.05.2023 17:21:48 Normal Casc
automatic log for run 85
Comment:
VCLIP 150
  140   Sat May 6 17:28:18 2023 TB crewMPX2 MPW3 TB86RD50-MPW383Low Flux MediumProton3144767Good06.05.2023 17:22:3106.05.2023 17:27:26 Normal Casc
automatic log for run 86
Comment:
  141   Sat May 6 17:34:40 2023 TB crewMPX2 MPW3 TB87RD50-MPW362.4Low Flux MediumProton2483890Good06.05.2023 17:27:5906.05.2023 17:33:48 Normal Casc
automatic log for run 87
Comment:
  142   Sat May 6 17:40:43 2023 TB crewMPX2 MPW3 TB88RD50-MPW362.4Low Flux MediumProton1801111Good06.05.2023 17:34:2806.05.2023 17:39:52 Normal Casc
automatic log for run 88
Comment:
VCLIP 150
  143   Sat May 6 17:47:27 2023 Bernhard PilslSW adjustment RD50-MPW3         

SW adjustment to MPW3-DC

Not dropping frame if it contains no trigger but data is alrdy buffered in unpacker buffer

  179   Sat Oct 14 22:15:13 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
about to start

Geometry for Corryvreckan attached
  180   Sat Oct 14 22:32:07 2023 tb crewRD50-MPW317RD50-MPW3800Low Flux LowProton Unknown14.10.2023 22:26:1014.10.2023 22:32:316Normal
automatic log for run 17
Comment:
  181   Sat Oct 14 22:37:52 2023 tb crewRD50-MPW318RD50-MPW3800Low Flux LowProton Unknown14.10.2023 22:34:4814.10.2023 22:38:163Normal
automatic log for run 18
Comment:
problem with scintis
  182   Sat Oct 14 22:39:24 2023 tb crewRD50-MPW319RD50-MPW3800Low Flux LowProton Unknown14.10.2023 22:38:5314.10.2023 22:39:480Normal
automatic log for run 19
Comment:
problem with scintis
  183   Sat Oct 14 22:41:45 2023 tb crewRD50-MPW320RD50-MPW3800Low Flux LowProton Unknown14.10.2023 22:40:4514.10.2023 22:42:091Normal
automatic log for run 20
Comment:
problem with scintis
  184   Sat Oct 14 23:09:30 2023 tb crewRD50-MPW323RD50-MPW3800Low Flux LowProton Unknown14.10.2023 23:01:3114.10.2023 23:09:548Normal
automatic log for run 23
Comment:
fixed scintis, debugging other stuff now
  185   Sat Oct 14 23:29:22 2023 tb crewRD50-MPW324RD50-MPW3800Low Flux LowProton Unknown14.10.2023 23:10:3514.10.2023 23:29:4619Normal
automatic log for run 24
Comment:
fixed scintis, debugging other stuff now
  186   Sat Oct 14 23:35:40 2023 tb crewRD50-MPW325RD50-MPW3800Low Flux LowProton Unknown14.10.2023 23:31:0114.10.2023 23:36:045Normal
automatic log for run 25
Comment:
debugging mpw3 udp path
  187   Sun Oct 15 00:01:45 2023 tb crewRD50-MPW326RD50-MPW3800Low Flux LowProton Unknown14.10.2023 23:51:3215.10.2023 00:02:0910Normal
automatic log for run 26
Comment:
finally mpw3 data

if not setup properly
  188   Sun Oct 15 00:13:45 2023 tb crewRD50-MPW327RD50-MPW3800Low Flux LowProton Unknown15.10.2023 00:02:4615.10.2023 00:14:0911Normal
automatic log for run 27
Comment:
finally mpw3 data

if not setup properly
  189   Sun Oct 15 00:29:44 2023 tb crewRD50-MPW328RD50-MPW3800Low Flux LowProton Unknown15.10.2023 00:14:1715.10.2023 00:30:0815Normal
automatic log for run 28
Comment:
finally mpw3 data

if not setup properly
  190   Sun Oct 15 00:39:39 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
running Corry now, MPW3 looks not good, telescope fine
  191   Sun Oct 15 00:40:22 2023 tb crewRD50-MPW329RD50-MPW3800Low Flux LowProton Unknown15.10.2023 00:33:0815.10.2023 00:40:467Normal
automatic log for run 29
Comment:
running Corry now, MPW3 looks not good, telescope fine
  192   Sun Oct 15 00:41:26 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
MPW3 was not in AIDA mode Frown
changed eudaq config
  193   Sun Oct 15 00:45:21 2023 tb crewRD50-MPW330RD50-MPW3800Low Flux LowProton Unknown15.10.2023 00:44:0315.10.2023 00:45:451Normal
automatic log for run 30
Comment:
  194   Sun Oct 15 01:09:42 2023 tb crewRD50-MPW332RD50-MPW3800Low Flux LowProton Unknown15.10.2023 00:52:3215.10.2023 01:10:0617Normal
automatic log for run 32
Comment:
  195   Sun Oct 15 01:13:49 2023 tb crewRD50-MPW333RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:10:4315.10.2023 01:14:133Normal
automatic log for run 33
Comment:
taking data
  196   Sun Oct 15 01:15:44 2023 tb crewRD50-MPW334RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:15:0015.10.2023 01:16:091Normal
automatic log for run 34
Comment:
taking data
  197   Sun Oct 15 01:22:37 2023 tb crewRD50-MPW335RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:17:0815.10.2023 01:23:015Normal
automatic log for run 35
Comment:
taking data
  198   Sun Oct 15 01:33:12 2023 tb crewRD50-MPW336RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:23:1915.10.2023 01:33:3610Normal
automatic log for run 36
Comment:
taking data
  199   Sun Oct 15 01:36:43 2023 tb crewRD50-MPW337RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:34:3615.10.2023 01:37:072Normal
automatic log for run 37
Comment:
taking data
  200   Sun Oct 15 01:37:16 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
mpw3 in noise
  201   Sun Oct 15 01:38:12 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
changed thr to 1.25V
  202   Sun Oct 15 02:05:00 2023 tb crewRD50-MPW338RD50-MPW3800Low Flux LowProton Unknown15.10.2023 01:40:2115.10.2023 02:05:2425Normal
automatic log for run 38
Comment:
  203   Sun Oct 15 02:17:53 2023 tb crewRD50-MPW339RD50-MPW3800Low Flux LowProton Unknown15.10.2023 02:05:4215.10.2023 02:18:1712Normal
automatic log for run 39
Comment:
  204   Sun Oct 15 02:42:11 2023 tb crewRD50-MPW340RD50-MPW3800Low Flux LowProton Unknown15.10.2023 02:18:3015.10.2023 02:42:3524Normal
automatic log for run 40
Comment:
  205   Sun Oct 15 02:44:18 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
Did ignore tracker veto
data nonsense until now
  206   Sun Oct 15 03:02:44 2023 tb crewRD50-MPW341RD50-MPW3800Low Flux LowProton Unknown15.10.2023 02:43:5415.10.2023 03:03:0819Normal
automatic log for run 41
Comment:
  207   Sun Oct 15 03:30:11 2023 tb crewRD50-MPW342RD50-MPW3800Low Flux LowProton Unknown15.10.2023 03:03:3515.10.2023 03:30:3527Normal
automatic log for run 42
Comment:
  208   Sun Oct 15 03:44:29 2023 tb crewRD50-MPW343RD50-MPW3800Low Flux LowProton Unknown15.10.2023 03:30:4715.10.2023 03:44:5414Normal
automatic log for run 43
Comment:
  209   Sun Oct 15 03:55:01 2023 tb crewRD50-MPW344RD50-MPW3800Low Flux LowProton Unknown15.10.2023 03:45:0715.10.2023 03:55:2610Normal
automatic log for run 44
Comment:
  210   Sun Oct 15 04:07:49 2023 tb crewRD50-MPW345RD50-MPW3800Low Flux LowProton Unknown15.10.2023 03:55:3615.10.2023 04:08:1412Normal
automatic log for run 45
Comment:
  211   Sun Oct 15 04:18:15 2023 tb crewRD50-MPW346RD50-MPW3800Low Flux LowProton Unknown15.10.2023 04:08:2315.10.2023 04:18:3910Normal
automatic log for run 46
Comment:
  212   Sun Oct 15 04:39:11 2023 tb crewRD50-MPW347RD50-MPW3800Low Flux LowProton Unknown15.10.2023 04:18:4815.10.2023 04:39:3620Normal
automatic log for run 47
Comment:
  213   Sun Oct 15 04:49:46 2023 tb crewRD50-MPW348RD50-MPW3800Low Flux LowProton Unknown15.10.2023 04:39:4515.10.2023 04:50:1010Normal
automatic log for run 48
Comment:
  214   Sun Oct 15 04:54:08 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
changed to sams estest FW (DESY success FW) for comparison
  215   Sun Oct 15 05:05:56 2023 tb crewRD50-MPW349RD50-MPW3800Low Flux LowProton Unknown15.10.2023 04:55:2215.10.2023 05:06:2010Normal
automatic log for run 49
Comment:
changed to sams bestest FW (DESY success FW) for comparison
  216   Sun Oct 15 05:16:57 2023 tb crewRD50-MPW350RD50-MPW3800Low Flux LowProton Unknown15.10.2023 05:06:3115.10.2023 05:17:2210Normal
automatic log for run 50
Comment:
changed to sams bestest FW (DESY success FW) for comparison
  217   Sun Oct 15 05:38:43 2023 tb crewRD50-MPW351RD50-MPW3800Low Flux LowProton Unknown15.10.2023 05:17:3115.10.2023 05:39:0821Normal
automatic log for run 51
Comment:
changed to sams bestest FW (DESY success FW) for comparison
  218   Sun Oct 15 05:54:29 2023 tb crewRD50-MPW352RD50-MPW3800Low Flux LowProton Unknown15.10.2023 05:39:1815.10.2023 05:54:5315Normal
automatic log for run 52
Comment:
changed to sams bestest FW (DESY success FW) for comparison
  219   Sun Oct 15 05:54:49 2023 tb crewRD50-MPW3 RD50-MPW3800Low Flux LowProton Unknown   Normal
new shifters arrived
  1   Sat Feb 18 14:48:36 2023 Bernhard PilslMPW3 Kalibration / Config Files           

Initial config files for the RD50_MPW3 Peary device

  4   Sat Feb 18 22:17:31 2023 Bernhard PilslAttention RUN NUMBER           

Due to bug in Elog-RC entries here for the shift on 18.02.2023 are bigger (+1) than the one stored in the data file names
eg run 9999 ( in name of *.raw files) is listed as 10000 in here

  55   Thu Apr 27 15:40:07 2023 Felix Ulrich-Purlow flux p800 recommissioning001 8002kHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
Rates slightly lower due to additional material in front of RaMon.

  56   Thu Apr 27 15:42:25 2023 Felix Ulrich-Purlow flux p800 recommissioning002 8005kHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
rate slightly lower due to additional material in front
 

  57   Thu Apr 27 15:43:21 2023 Felix Ulrich-Purlow flux p800 recommissioning003 800200kHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
rate slightly lower due to additional material in front
 

  58   Thu Apr 27 15:43:48 2023 Felix Ulrich-Purlow flux p800 recommissioning004 8001.2MHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
rate slightly lower due to additional material in front
 

  59   Thu Apr 27 15:44:37 2023 Felix Ulrich-Purlow flux p800 recommissioning005 8001.2MHzProton Good    

Measurement with RaMon 22.04.23 (not placed in isocentre) LGAD beam telescope was placed in front. LGADs were moved out of the beam. 4x PCB was in front of the RaMon scintillators (5x5cm^2)
rate slightly lower due to additional material in front
higher voltage in PMTs (no significant change in rate)

  60   Thu Apr 27 15:45:23 2023 Felix Ulrich-PurLGAD beam telescope calibration007 800200kHzProton Good    

22.04.23 trigger on second LGAD (run 006 is missing since cable of pre-amps was loose and 3rd sensor signal was lost)

  61   Thu Apr 27 15:47:05 2023 Felix Ulrich-PurLGAD beam telescope calibration008 800200kHzProton Good    

22.04.23 23:20 trigger on third LGAD

beam spot was off. telescope was shifted

  62   Thu Apr 27 15:48:29 2023 Felix Ulrich-PurLGAD beam telescope calibration009 83Low Flux MediumProton Good    

22.04.23 23:35 trigger on third LGAD

no DUT

  63   Thu Apr 27 15:49:27 2023 Felix Ulrich-PurLGAD beam telescope calibration010 252.7Low Flux MediumProton Good    

22.04.23 23:58 trigger on third LGAD

no DUT

beam was down between 00:05 and 00:15

  64   Thu Apr 27 15:49:58 2023 Felix Ulrich-PurLGAD beam telescope calibration011 145.4Low Flux MediumProton Good    

23.04.23 00:17 trigger on third LGAD

no DUT

  65   Thu Apr 27 15:50:55 2023 Felix Ulrich-PurLGAD beam telescope calibration012 100.4Low Flux MediumProton Good    

23.04.23 00:35 trigger on third LGAD

no DUT

  66   Thu Apr 27 15:51:18 2023 Felix Ulrich-Pursandwich TOF-iCT calibration013 100.4Low Flux MediumProton Good    

23.04.23 01:09 trigger on third LGAD

6 PMMA slabs (~1cm)

  67   Thu Apr 27 15:52:02 2023 Felix Ulrich-Pursandwich TOF-iCT calibration014 83Low Flux MediumProton Good    

23.04.23 01:26 trigger on third LGAD

6 PMMA slabs (~1cm)

  68   Thu Apr 27 15:52:25 2023 Felix Ulrich-Pursandwich TOF-iCT calibration015 100.4Low Flux MediumProton Good    

23.04.23 01:47 trigger on third LGAD

3 PMMA slabs (~0.5cm)

 

01:53 fail accelerator

  69   Thu Apr 27 15:53:11 2023 Felix Ulrich-Pursandwich TOF-iCT calibration016 83Low Flux MediumProton Good    

23.04.23 02:07 trigger on third LGAD

3 PMMA slabs (~0.5cm)

  70   Thu Apr 27 15:53:54 2023 Felix Ulrich-Pursandwich TOF-iCT calibration017 100.4Low Flux MediumProton Good    

23.04.23 02:28 trigger on third LGAD

9 PMMA slabs (~1.5cm)

  71   Thu Apr 27 15:54:15 2023 Felix Ulrich-Pursandwich TOF-iCT calibration018 83Low Flux MediumProton Good    

23.04.23 02:43 trigger on third LGAD

9 PMMA slabs (~1.5cm)

  72   Thu Apr 27 15:55:35 2023 Felix Ulrich-Pursandwich TOF-iCT calibration019 100.4Low Flux MediumProton Good    

23.04.23 03:05 trigger on third LGAD

12 PMMA slabs (~2cm)

  73   Thu Apr 27 15:56:18 2023 Felix Ulrich-Pursandwich TOF-iCT calibration020 83Low Flux MediumProton Good    

23.04.23 03:19 trigger on third LGAD

12 PMMA slabs (~2cm)

  74   Thu Apr 27 15:56:37 2023 Felix Ulrich-Pursandwich TOF-iCT calibration021 100.4Low Flux MediumProton Good    

23.04.23 03:40 trigger on third LGAD

15 PMMA slabs (~2.5cm)

  75   Thu Apr 27 15:57:31 2023 Felix Ulrich-Pursandwich TOF-iCT calibration022 83Low Flux MediumProton Good    

23.04.23 03:58 trigger on third LGAD

15 PMMA slabs (~2.5cm)

  76   Thu Apr 27 15:58:04 2023 Felix Ulrich-Pursandwich TOF-iCT calibration023 100.4Low Flux MediumProton Good    

23.04.23 04:20 trigger on third LGAD

18 PMMA slabs (~3cm)

  77   Thu Apr 27 15:58:35 2023 Felix Ulrich-Pursandwich TOF-iCT calibration024 83Low Flux MediumProton Good    

23.04.23 04:37 trigger on third LGAD

18 PMMA slabs (~3cm)

  78   Thu Apr 27 15:59:00 2023 Felix Ulrich-Pursandwich TOF-iCT calibration025 100.4Low Flux MediumProton Good    

23.04.23 05:00 trigger on third LGAD

21 PMMA slabs (~3.5cm)

  79   Thu Apr 27 15:59:29 2023 Felix Ulrich-Pursandwich TOF-iCT calibration026 83Low Flux MediumProton Good    

23.04.23 05:18 trigger on third LGAD

21 PMMA slabs (~3.5cm)

  80   Thu Apr 27 15:59:52 2023 Felix Ulrich-Pursandwich TOF-iCT radiography027 100.4Low Flux MediumProton Good    

23.04.23 05:55 trigger on third LGAD

1cm Al stair phantom profile view (i.e. only 1cm Al) 0deg

  81   Thu Apr 27 16:00:47 2023 Felix Ulrich-Pursandwich TOF-iCT radiography028 83Low Flux MediumProton Good    

23.04.23 07:35 trigger on third LGAD

1cm Al stair phantom profile view (i.e. only 1cm Al) 0deg

  82   Thu Apr 27 16:01:39 2023 Felix Ulrich-Pursandwich TOF-iCT radiography029 83Low Flux MediumProton Good    

23.04.23 09:36 trigger on third LGAD

1cm Al stair phantom frontal view (i.e. 5 steps) 90deg

  83   Thu Apr 27 16:02:23 2023 Felix Ulrich-Pursandwich TOF-iCT calibration030 100.4Low Flux MediumProton Good    

23.04.23 10:38 trigger on third LGAD

20 PMMA slabs

  84   Thu Apr 27 16:03:21 2023 Felix Ulrich-Pursandwich TOF-iCT calibration031 83Low Flux MediumProton Good    

23.04.23 10:53 trigger on third LGAD

20 PMMA slabs

  85   Thu Apr 27 16:03:48 2023 Felix Ulrich-Pursandwich TOF-iCT calibration032 100.4Low Flux MediumProton Good    

23.04.23 11:13 trigger on third LGAD

19 PMMA slabs

  86   Thu Apr 27 16:04:40 2023 Felix Ulrich-Pursandwich TOF-iCT calibration034 83Low Flux MediumProton Good    

23.04.23 11:43 trigger on third LGAD

19 PMMA slabs

run 33 is missing as accelerator failed

  87   Thu Apr 27 16:06:01 2023 Felix Ulrich-Pursandwich TOF-iCT calibration035 83Low Flux MediumProton Good    

23.04.23 12:03 trigger on third LGAD

17 PMMA slabs

 

  88   Thu Apr 27 16:06:30 2023 Felix Ulrich-Pursandwich TOF-iCT radiography036 83Low Flux MediumProton Good    

23.04.23 12:35 trigger on third LGAD

2cm Al slab with hole (in front of only half of the sensor)

 

  89   Thu Apr 27 16:07:51 2023 Felix Ulrich-Pursandwich TOF-iCT radiography037 100.4Low Flux MediumProton Good    

23.04.23 13:00 trigger on third LGAD

2cm Al slab with hole (in front of only half of the sensor)

 

  92   Sat May 6 07:27:05 2023 Bernhard PilslLocal Run Tracker99          

XML für local run: MPW3_TJMP2_20230506_00-000099.xml

XML für TLU runs (global): MPW3_TJMP2_20230506_TLU_00-000099.xml 

  122   Sat May 6 14:16:53 2023 Christian IrmlerSensor orientation           

Orientation of tracker, MPW3 and TJMP2