  313   Sat Oct 8 07:20:45 2022 Christian Irmlertestrun ramon + tracker + DUT2RD50-MPW3800   Craplowflux high       Tracker timing wrong, latency too low,
peak at 0 --> changed lat from 40 to 41
for next run.
  
  314   Sat Oct 8 07:28:42 2022 Christian Irmlertestrun ramon + tracker + DUT3RD50-MPW3800   Unknownlowflux high       Tracker latency lat=42   
  315   Sat Oct 8 07:30:37 2022 Christian Irmlertestrun ramon + tracker + DUT4RD50-MPW3800   Unknownlowflux high       Tracker latency lat=42

RD50-MPW3 monitor connected first
 beam-profil-tracker.pngtiming_tracker.png 
  316   Sat Oct 8 07:40:51 2022 Christian Irmlerramon + tracker + DUT5RD50-MPW3800  24260338Goodlowflux high       Tracker latency lat=42

First data run w/ ramon + tracker
+ MPW3 + monitor connected
  
  317   Sat Oct 8 08:43:15 2022 Christian Irmlerramon + tracker + DUT6RD50-MPW3252.7   Goodlowflux high       ~4 MHz particle rate
MPW3 data file size after 5 minutes:
11 GB :-$
 APV_sync_error.png 
  318   Sat Oct 8 09:02:20 2022 Patrick Siebererramon + tracker + DUT7RD50-MPW3252.7  5 min data takingGoodlowflux high       First data run w/ ramon + tracker + MPW3
+ monitor connected
  
  319   Sat Oct 8 09:07:48 2022 Patrick Siebererramon + tracker + DUT8RD50-MPW3252.7  kurzGoodlowflux high       short run for uploading to analysis   
  320   Sat Oct 8 09:08:13 2022 Patrick Siebererramon + tracker + DUT9RD50-MPW3252.7  kurzGoodlowflux high       TLU: 6,8M Tracker nur 4 M -> Let's
reset FADC
  
  321   Sat Oct 8 09:19:01 2022 Patrick Siebererramon + tracker + DUT10RD50-MPW3252.7   Goodlowflux high       repeat run 9

max_trgs: 100

tracker still not working.
 run9_hitmap_tracker.png 
  322   Sat Oct 8 09:33:59 2022 Patrick Siebererramon + tracker + DUT12RD50-MPW3252.7  9.8MGoodlowflux high       repeat run 9 again ;)

run 11 used for new local runs
of tracker - hvcmos_mpw3_20221008_11_TLU_00-000011.xml
  
  323   Sat Oct 8 09:46:15 2022 Patrick Siebererramon + tracker + DUT13RD50-MPW3252.7   Goodlowflux low       Ratenwechsel

Tracker: latency 42 > timing
much better
 timing_tracker_run13.pngtracker_hitmap_run9.png 
  324   Sat Oct 8 10:11:27 2022 Patrick Siebererramon + tracker + DUT14RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300   
  325   Sat Oct 8 10:16:45 2022 Patrick Siebererramon + tracker + DUT15RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300
BEAM OFF, for TH check
  
  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check
  
  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1600 - too high
BEAM OFF, for TH check
  
  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1400
BEAM OFF, for TH check
  
  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300 again for verificationn -
still too many noise hits
BEAM OFF, for TH check
  
  330   Sat Oct 8 10:32:44 2022 Christian Irmlerramon + tracker + DUT20RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected -->
  
  331   Sat Oct 8 10:35:23 2022 Christian Irmlerramon + tracker + DUT21RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

no noise hits
  
  332   Sat Oct 8 10:37:45 2022 Christian Irmlerramon + tracker + DUT22RD50-MPW3252.7   Unknownlowflux low       ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at
  