Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 18 of 18  Not logged in ELOG logo
ID Date Author Subject Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatronup Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle Text Attachments
  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check
  
  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1600 - too high
BEAM OFF, for TH check
  
  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1400
BEAM OFF, for TH check
  
  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       ASIC: TH 1300 again for verificationn -
still too many noise hits
BEAM OFF, for TH check
  
  330   Sat Oct 8 10:32:44 2022 Christian Irmlerramon + tracker + DUT20RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected -->
  
  331   Sat Oct 8 10:35:23 2022 Christian Irmlerramon + tracker + DUT21RD50-MPW3252.7   Craplowflux low       ASIC: TH 1350
BEAM OFF, for TH check

no noise hits
  
  332   Sat Oct 8 10:37:45 2022 Christian Irmlerramon + tracker + DUT22RD50-MPW3252.7   Unknownlowflux low       ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at
  
  333   Sat Oct 8 10:40:04 2022 Christian Irmlerramon + tracker + DUT23RD50-MPW3252.7   Unknownlowflux low       ASIC: TH 1330
BEAM ON all included

 
 
  
  334   Sat Oct 8 10:56:01 2022 Christian Irmlerramon + tracker + DUT24RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1330
BEAM ON all included

 
  
  335   Sat Oct 8 10:58:00 2022 Christian Irmlerramon + tracker + DUT25RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1310 seems to be okay
BEAM ON all included

2 GUIs started -> New Run
  
  336   Sat Oct 8 11:04:33 2022 Patrick Siebererramon + tracker + DUT26RD50-MPW3100.4   Unknownlowflux low       ASIC: TH 1310 seems to be okay
BEAM ON all included

 
  
ELOG V3.1.5-fc6679b