Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021  Not logged in ELOG logo
Message ID: 317     Entry time: Sat Oct 8 08:43:15 2022
Author: Christian Irmler 
Subject: ramon + tracker + DUT 
Run Number:
DUT: RD50-MPW3 
Beam Energy: 252.7 
Rate Setting:  
Particle Type:  
Events:  
Data: Good 
Beam Betatron: lowflux high 
Beam Chopper:  
Beam Degrader:  
Beam EFE:  
Beam Orb:  
Beam QuadScan:  
PhantomType:  
PhantomAngle:  

~4 MHz particle rate
MPW3 data file size after 5 minutes: 11 GB :-$

Tracker lost data again.
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Warning::UDPUnpacker::Expected package number 1953610, got: 1953990!
 

Sync-Error L5.1.1 and L5.1.2

Attachment 1: APV_sync_error.png  16 kB  Uploaded Sat Oct 8 10:06:36 2022  | Hide | Hide all
APV_sync_error.png
ELOG V3.1.5-fc6679b