Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-MA2018 testbeam-MA2019 testbeam-MA2020 testbeam-MA2021 testbeam-MA2023 testbeam-MA2024
  MedAustron 2021, Page 1 of 18  Not logged in ELOG logo
ID Date Author Subjectdown Run Number DUT Beam Energy Rate Setting Particle Type Events Data Beam Betatron Beam Chopper Beam Degrader Beam EFE Beam Orb Beam QuadScan PhantomType PhantomAngle
  313   Sat Oct 8 07:20:45 2022 Christian Irmlertestrun ramon + tracker + DUT2RD50-MPW3800   Craplowflux high       

Tracker timing wrong, latency too low, peak at 0 --> changed lat from 40 to 41 for next run.

  314   Sat Oct 8 07:28:42 2022 Christian Irmlertestrun ramon + tracker + DUT3RD50-MPW3800   Unknownlowflux high       

Tracker latency lat=42

  315   Sat Oct 8 07:30:37 2022 Christian Irmlertestrun ramon + tracker + DUT4RD50-MPW3800   Unknownlowflux high       

Tracker latency lat=42

RD50-MPW3 monitor connected first

Attachment 1: beam-profil-tracker.png
beam-profil-tracker.png
Attachment 2: timing_tracker.png
timing_tracker.png
  316   Sat Oct 8 07:40:51 2022 Christian Irmlerramon + tracker + DUT5RD50-MPW3800  24260338Goodlowflux high       

Tracker latency lat=42

First data run w/ ramon + tracker + MPW3 + monitor connected

Tracker dropped some udp packages, total tracker events 23166448

  317   Sat Oct 8 08:43:15 2022 Christian Irmlerramon + tracker + DUT6RD50-MPW3252.7   Goodlowflux high       

~4 MHz particle rate
MPW3 data file size after 5 minutes: 11 GB :-$

Tracker lost data again.
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Error::FADCGbEMerger::Event missmatch
[2022-10-08 08:49:11 CEST]    Warning::UDPUnpacker::Expected package number 1953610, got: 1953990!
 

Sync-Error L5.1.1 and L5.1.2

Attachment 1: APV_sync_error.png
APV_sync_error.png
  318   Sat Oct 8 09:02:20 2022 Patrick Siebererramon + tracker + DUT7RD50-MPW3252.7  5 min data takingGoodlowflux high       

First data run w/ ramon + tracker + MPW3 + monitor connected

  319   Sat Oct 8 09:07:48 2022 Patrick Siebererramon + tracker + DUT8RD50-MPW3252.7  kurzGoodlowflux high       

short run for uploading to analysis

  320   Sat Oct 8 09:08:13 2022 Patrick Siebererramon + tracker + DUT9RD50-MPW3252.7  kurzGoodlowflux high       

TLU: 6,8M Tracker nur 4 M -> Let's reset FADC

  321   Sat Oct 8 09:19:01 2022 Patrick Siebererramon + tracker + DUT10RD50-MPW3252.7   Goodlowflux high       

repeat run 9

max_trgs: 100

tracker still not working.

Attachment 1: run9_hitmap_tracker.png
run9_hitmap_tracker.png
  322   Sat Oct 8 09:33:59 2022 Patrick Siebererramon + tracker + DUT12RD50-MPW3252.7  9.8MGoodlowflux high       

repeat run 9 again ;)

run 11 used for new local runs of tracker - hvcmos_mpw3_20221008_11_TLU_00-000011.xml

tracker seems fine, at least in the beginning

again APV sync errors at the end of the run

  323   Sat Oct 8 09:46:15 2022 Patrick Siebererramon + tracker + DUT13RD50-MPW3252.7   Goodlowflux low       

Ratenwechsel

Tracker: latency 42 > timing much better

ASIC: TH 1200

Attachment 1: timing_tracker_run13.png
timing_tracker_run13.png
Attachment 2: tracker_hitmap_run9.png
tracker_hitmap_run9.png
  324   Sat Oct 8 10:11:27 2022 Patrick Siebererramon + tracker + DUT14RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1300

  325   Sat Oct 8 10:16:45 2022 Patrick Siebererramon + tracker + DUT15RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1300
BEAM OFF, for TH check

  326   Sat Oct 8 10:21:20 2022 Christian Irmlerramon + tracker + DUT16RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1800 - too high, no noise hits
BEAM OFF, for TH check

  327   Sat Oct 8 10:24:12 2022 Christian Irmlerramon + tracker + DUT17RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1600 - too high
BEAM OFF, for TH check

  328   Sat Oct 8 10:29:27 2022 Christian Irmlerramon + tracker + DUT18RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1400
BEAM OFF, for TH check

  329   Sat Oct 8 10:30:38 2022 Christian Irmlerramon + tracker + DUT19RD50-MPW3252.7   Goodlowflux low       

ASIC: TH 1300 again for verificationn - still too many noise hits
BEAM OFF, for TH check

  330   Sat Oct 8 10:32:44 2022 Christian Irmlerramon + tracker + DUT20RD50-MPW3252.7   Craplowflux low       

ASIC: TH 1350
BEAM OFF, for TH check

MPW3 monitor not connected --> invalid

  331   Sat Oct 8 10:35:23 2022 Christian Irmlerramon + tracker + DUT21RD50-MPW3252.7   Craplowflux low       

ASIC: TH 1350
BEAM OFF, for TH check

no noise hits

 

  332   Sat Oct 8 10:37:45 2022 Christian Irmlerramon + tracker + DUT22RD50-MPW3252.7   Unknownlowflux low       

ASIC: TH 1330
BEAM OFF, for TH check

only few (1 or 2) pixel fire at a low frequency.

Will use this threshold from now on.

 

 

ELOG V3.1.5-fc6679b