Tue Jan 7 11:52:27 2014, Markus Friedl, Infineon, run, run019, 650k, 07.01.2014 11:47:24, 07.01.2014 13:15:21, Good
|
HV=300V I=9.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single sample run
Beam energy = 3 GeV |
Tue Jan 7 13:20:48 2014, Markus Friedl, Infineon, run, run020, 300k, 07.01.2014 13:18:52, 07.01.2014 14:35:49, Good
|
HV=300V I=8.5uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
multi6 with same settings as run019 (htr+3)
Beam energy = 3 GeV |
Tue Jan 7 14:47:38 2014, Markus Friedl, Infineon, run, run021, 200k, 07.01.2014 14:46:08, 07.01.2014 15:13:23, Good
|
HV=100V I=7.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:16:11 2014, Markus Friedl, Infineon, run, run022, 200k, 07.01.2014 15:15:09, 07.01.2014 15:42:17, Good
|
HV=150V I=7.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 15:54:22 2014, Markus Friedl, Infineon, run, run023, 200k, 07.01.2014 15:53:06, 07.01.2014 16:25:26, Good
|
HV=200V I=8.0uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 16:36:49 2014, Markus Friedl, Infineon, run, run024, 200k, 07.01.2014 16:35:44, 07.01.2014 17:03:10, Good
|
HV=210V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 17:09:56 2014, Markus Friedl, Infineon, run, run025, 200k, 07.01.2014 17:08:54, 07.01.2014 17:36:12, Good
|
HV=220V I=8.1uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 17:39:20 2014, Markus Friedl, Infineon, run, run026, 200k, 07.01.2014 17:38:01, 07.01.2014 18:05:11, Good
|
HV=230V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 18:11:52 2014, Markus Friedl, Infineon, run, run027, 200k, 07.01.2014 18:10:45, 07.01.2014 18:37:42, Good
|
HV=240V I=8.2uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 18:41:55 2014, Markus Friedl, Infineon, run, run028, 200k, 07.01.2014 18:40:40, 07.01.2014 19:07:32, Good
|
HV=250V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 19:12:07 2014, Markus Friedl, Infineon, run, run029, 200k, 07.01.2014 19:11:05, 07.01.2014 19:38:00, Good
|
HV=260V I=8.7uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 19:44:45 2014, Markus Friedl, Infineon, run, run030, 200k, 07.01.2014 19:43:35, 07.01.2014 20:11:03, Good
|
HV=270V I=8.6uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 20:26:50 2014, Markus Friedl, Infineon, run, run031, 200k, 07.01.2014 20:25:32, 07.01.2014 20:58:47, Good
|
HV=280V I=8.4uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 21:02:58 2014, Markus Friedl, Infineon, run, run032, 200k, 07.01.2014 21:01:42, 07.01.2014 21:29:03, Good
|
HV=290V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV |
Tue Jan 7 21:34:41 2014, Markus Friedl, Infineon, run, run033, 4.117.024 (4M), 07.01.2014 21:33:12, 08.01.2014 08:52:37, Good
|
HV=300V I=8.3uA
position adapted to center beam better (+10mm horizontal)
narrow trigger width (~5ns)
single trigger
Beam energy = 3 GeV
beam gone at 8:00 morning because of scheduled beam development. last few 100 events only noise. |
Fri Jan 24 18:02:46 2014, Wolfgang Treberspurg, Infineon, New Infineon Stack, , , , , Good
|
Exchanged AIDA stack with modified Infineon Stack
Configuration:
Beam Infineon_TB_2014_Baby1(P0) --- Inifineon_TB_2014_Baby2(P1) ||| Infineon_TB_2012_Baby2(P2) --- Infineon_TB_2012_Baby1(P3) ||| Infineon_TB_2012_Strixel_Top-left(N0) --- Infineon_TB_2012_Strixel_Bottom-right(N1) --- |
Sat Jan 25 18:24:03 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_001, 1.05 M, 25.01.2014 10:30, 25.01.2014 15:40, Unknown
|
HV at 300V; I at app. 11µA 4GeV, Single mode
Modules centered to beam but no hits at additional Strixel modul. Perhaps HV problems (High noise of Strixel almost did not change after biasing)
-> HV connection will be checked at next opportunity to enter area. |
Sat Jan 25 18:28:38 2014, Wolfgang Treberspurg, Infineon, Calibration run Infineon Stack 2, Calibration_Run_Infineon_Stack2_001, 82900, 25.01.2014 10:15, 25.01.2014 10:25, Unknown
|
HV 300V, I ca. 11µA single mode |
Sat Jan 25 18:46:32 2014, Wolfgang Treberspurg, Infineon, Mulit 6 mode Run Stack 2, HW_Run_Infineon_Stack2_Multi_001, 340k, 25.01.2014 16:30, 25.01.2014 18:40, Unknown
|
HV 300V, I 10µA
Beam Energy changed during the run between 2GeV - 5GeV - 4GeV
Latency perhaps not optimal set (has been 95) but exchanged trigger cable seems to require 93 |
Sat Jan 25 21:14:46 2014, Wolfgang Treberspurg, Infineon, Mulit 6 mode Run Stack 2, HW_Run_Infineon_Stack2_Multi_002, 230k, 25.01.2014 19:00, 25.01.2014 21:15, Good
|
HV 300V, I 10µA
Beam Energy 4GeV
Latency changed to 93 |
|