  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 4 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Numberdown Events XYPosition Cooling Data
  81   Tue Oct 24 18:09:43 2017 Peter PaulitschHPK_200run000279279110000NoGood
Parameter Value
Alibava filename  run000279.dat
Telescope filename  run000279.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  80   Tue Oct 24 18:09:24 2017 Peter PaulitschHPK_200run0002772771010000NoGood
Parameter Value
Alibava filename  run000277.dat
Telescope filename  run000277.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  79   Tue Oct 24 18:08:57 2017 Peter PaulitschHPK_200run0002752751010000NoGood
Parameter Value
Alibava filename  run000275.dat
Telescope filename  run000275.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  78   Tue Oct 24 18:08:38 2017 Peter PaulitschHPK_200run000273273110000NoGood
Parameter Value
Alibava filename  run000273.dat
Telescope filename  run000273.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  77   Tue Oct 24 18:08:06 2017 Peter PaulitschHPK_200run000271271110000NoGood
Parameter Value
Alibava filename  run000271.dat
Telescope filename  run000271.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  76   Tue Oct 24 18:04:09 2017 Peter PaulitschHPK_200run000266266110000NoGood
Parameter Value
Alibava filename  run000266.dat
Telescope filename  run000266.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  75   Tue Oct 24 18:02:47 2017 Peter PaulitschHPK_200run000264264110000NoGood
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  74   Tue Oct 24 18:02:07 2017 Peter PaulitschHPK_3e14run000263263301000075.93, 65.30, -70.55°YesGood
Parameter Value
Alibava filename  run000263.dat
Telescope filename  run000263.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  73   Tue Oct 24 18:01:13 2017 Peter PaulitschHPK_3e14run000261261101000075.93, 65.30, -70.55°YesGood
Parameter Value
Alibava filename  run000261.dat
Telescope filename  run000261.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  72   Tue Oct 24 17:59:58 2017 Peter PaulitschHPK_3e14run00025925911000075.93, 65.30, -70.55°YesGood
Parameter Value
Alibava filename  run000259.dat
Telescope filename  run000259.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current 37 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  71   Tue Oct 24 17:58:43 2017 Peter PaulitschHPK_3e14run000257257101000075.93, 65.30, -80.55°YesGood
Parameter Value
Alibava filename  run000257.dat
Telescope filename  run000257.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  70   Tue Oct 24 17:58:09 2017 Peter PaulitschHPK_3e14run00025525511000075.93, 65.30, -80.55°YesGood
Parameter Value
Alibava filename  run000255.dat
Telescope filename  run000255.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  69   Tue Oct 24 17:57:28 2017 Peter PaulitschHPK_3e14run00025125111000075.93, 65.30, -80.55°YesGood
Parameter Value
Alibava filename  run000251.dat
Telescope filename  run000251.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  68   Tue Oct 24 17:56:36 2017 Peter PaulitschHPK_3e14run000249249101000075.93, 65.30, -90.55°YesGood
Parameter Value
Alibava filename  run000249.dat
Telescope filename  run000249.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  67   Tue Oct 24 17:53:19 2017 Peter PaulitschHPK_3e14run00024824811000075.93, 65.30, -90.55°YesGood
Parameter Value
Alibava filename  run000248.dat
Telescope filename  run000248.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  66   Tue Oct 24 17:51:18 2017 Peter PaulitschHPK_3e14run000246246101000075.93, 65.30, -100.55°YesGood
Parameter Value
Alibava filename  run000246.dat
Telescope filename  run000246.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  64   Tue Oct 24 17:46:11 2017 Peter PaulitschHPK_3e14run00024424411000075.93, 65.30, -100.55°YesGood
Parameter Value
Alibava filename  run000244.dat
Telescope filename  run000244.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%
  65   Tue Oct 24 17:50:04 2017 Peter PaulitschHPK_3e14run000242242101000075.93, 65.30, -70.55°YesGood
Parameter Value
Alibava filename  run000242.dat
Telescope filename  run000242.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
  60   Mon Oct 23 09:24:23 2017 Dominic BloechHPK_3e14run000240240101000075.93, 65.30, -70.55°YesCrap
Parameter Value
Alibava filename  run000240.dat
Telescope filename  run000240.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -100 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time 80min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
  59   Sat Oct 21 10:22:43 2017 Peter PaulitschHPK_3e14run000237237301000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000237.dat
Telescope filename  run000237.raw
Pedestal filename KIT_HPK_200_3e14.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 4010000
Telescope triggers 4000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time night run
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%

 