Message ID: 75     Entry time: Tue Oct 24 18:02:47 2017
Author: Peter Paulitsch 
DUT: HPK_200 
Subject: run000264 
Run Number: 264 
Events: 110000 
XYPosition: 0° 
Cooling: No 
Data: Good 
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  