  105   Mon Apr 17 13:30:01 2017 Axel KoenigALiBaVa (IFX)run_001_HPK_CB_200V.dat001450000107, 0, 240NoUnknownRemarks: Telescope run 604. Bias scan 200
V. Only one chip.

Telescope chiller turned off (could
  
  125   Tue Apr 18 21:03:42 2017 Axel KoenigALiBaVa (IFX)run_003_double_irrad_100V.dat0033500000103, 1, 240NoUnknownRemarks: Telescope run 625. Both chips.
Central position. Run crashed over night.

Collected triggers 2710991.
  
  78   Sat Apr 15 18:31:14 2017 Axel KoenigALiBaVa (IFX)run_003_Baby_100V.dat003250000102.5, 32.5, 240NoUnknownRemarks: Telescope run 564. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  79   Sat Apr 15 19:20:34 2017 Axel KoenigALiBaVa (IFX)run_004_Baby_100V.dat004250000102.5, 22.5, 250NoUnknownRemarks: Telescope run 565. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  75   Sat Apr 15 16:52:06 2017 Axel KoenigALiBaVa (IFX)run_001_Baby_100V.dat001250000102.5, 22.5, 240NoUnknownRemarks: Telescope run 562. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  81   Sat Apr 15 21:18:26 2017 Axel KoenigALiBaVa (IFX)run_007_Baby_10V.dat007450000102.5, 22.5, 240NoCrapRemarks: Telescope run 579. Bias scan 10
V. run crashed. Data vaild up to 274915.

Telescope chiller turned off (could
  
  82   Sun Apr 16 13:15:55 2017 Axel KoenigALiBaVa (IFX)run_008_Baby_20V.dat008175000102.5, 22.5, 240NoUnknownRemarks: Telescope run 583. Bias scan 20
V. run crashed.

Telescope chiller turned off (could
  
  83   Sun Apr 16 15:44:35 2017 Axel KoenigALiBaVa (IFX)run_009_Baby_30V.dat009135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 586. Bias scan 30
V.

Telescope chiller turned off (could
  
  84   Sun Apr 16 17:42:06 2017 Axel KoenigALiBaVa (IFX)run_010_Baby_40V.dat010135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 587. Bias scan 40
V.

Telescope chiller turned off (could
  
  85   Sun Apr 16 18:25:59 2017 Axel KoenigALiBaVa (IFX)run_011_Baby_50V.dat011135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 588. Bias scan 50
V.

Telescope chiller turned off (could
  
  86   Sun Apr 16 19:04:41 2017 Axel KoenigALiBaVa (IFX)run_012_Baby_60V.dat012135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 589. Bias scan 60
V.

Telescope chiller turned off (could
  
  87   Sun Apr 16 19:46:01 2017 Axel KoenigALiBaVa (IFX)run_013_Baby_65V.dat013112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 590. Bias scan 65
V.

Telescope chiller turned off (could
  
  88   Sun Apr 16 20:22:27 2017 Axel KoenigALiBaVa (IFX)run_014_Baby_70V.dat014250000102.5, 22.5, 240NoUnknownRemarks: Telescope run 591. Bias scan 70
V.

Telescope chiller turned off (could
  
  90   Sun Apr 16 21:43:15 2017 Axel KoenigALiBaVa (IFX)run_015_Baby_100V.dat0152500000102.5, 22.5, 240NoUnknownRemarks: Telescope run 592. Long run, bias
voltage 100 V. Long run finished without
any problems.
  
  92   Mon Apr 17 08:14:24 2017 Axel KoenigALiBaVa (IFX)run_016_Baby_75V.dat016112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 593. Bias scan 75
V.

Telescope chiller turned off (could
  
  93   Mon Apr 17 09:01:09 2017 Axel KoenigALiBaVa (IFX)run_017_Baby_80V.dat017112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 594. Bias scan 80
V.

Telescope chiller turned off (could
  
  95   Mon Apr 17 09:29:40 2017 Axel KoenigALiBaVa (IFX)run_018_Baby_90V.dat018112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 595. Bias scan 90
V.

Telescope chiller turned off (could
  
  96   Mon Apr 17 10:05:57 2017 Axel KoenigALiBaVa (IFX)run_019_Baby_110V.dat019112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 596. Bias scan 110
V.

Telescope chiller turned off (could
  
  99   Mon Apr 17 10:36:22 2017 Axel KoenigALiBaVa (IFX)run_020_Baby_120V.dat020112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 597. Bias scan 120
V.

Telescope chiller turned off (could
  
  100   Mon Apr 17 11:04:40 2017 Axel KoenigALiBaVa (IFX)run_021_Baby_130V.dat021112000102.5, 22.5, 240NoUnknownRemarks: Telescope run 598. Bias scan 130
V.

Telescope chiller turned off (could
  