ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
59
|
Fri Apr 14 08:59:26 2017 |
Axel Koenig | ALiBaVa (IFX) | run_020_IFX_CB_100V.dat | 020 | 190000 | 109, 4.5, 240 | No | Crap |
Remarks: Telescope run 535. Bias scan 100 V. Run crashed over night. Telescope sync only up to event 190000 (planned 2500000 events).
Parameter |
Value |
Alibava run |
run_020_IFX_CB_100V.dat |
Telescope run |
535 |
Triggers |
190000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
99
|
Mon Apr 17 10:36:22 2017 |
Axel Koenig | ALiBaVa (IFX) | run_020_Baby_120V.dat | 020 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 597. Bias scan 120 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_020_Baby_120V.dat |
Telescope run |
597 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-120 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
147
|
Fri Apr 21 08:57:30 2017 |
Axel Koenig | ALiBaVa (IFX) | run_020_Irrad_500V.dat | 020 | 200000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 652. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Beam energy scan.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_020_Irrad_500V.dat |
Telescope run |
652 |
Triggers |
200000 |
Alibava trigger eff. |
~70% |
Beam energy |
4.8 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
96
|
Mon Apr 17 10:05:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_019_Baby_110V.dat | 019 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 596. Bias scan 110 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_019_Baby_110V.dat |
Telescope run |
596 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-110 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
146
|
Fri Apr 21 08:38:17 2017 |
Axel Koenig | ALiBaVa (IFX) | run_019_Irrad_500V.dat | 019 | 200000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 651. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Beam energy scan.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_019_Irrad_500V.dat |
Telescope run |
651 |
Triggers |
200000 |
Alibava trigger eff. |
~70% |
Beam energy |
5 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
36
|
Thu Apr 13 21:23:11 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_IFX_CB_120V.dat | 018 | 175000 | 109, 4.5, 240 | No | Unknown |
Remarks: Telescope run 533. Bias scan 120 V.
Parameter |
Value |
Alibava run |
run_018_IFX_CB_120V.dat |
Telescope run |
533 |
Triggers |
175000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-120 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
95
|
Mon Apr 17 09:29:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_Baby_90V.dat | 018 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 595. Bias scan 90 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_018_Baby_90V.dat |
Telescope run |
595 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-90 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
145
|
Fri Apr 21 08:15:03 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_Irrad_500V.dat | 018 | 200000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 650. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Beam energy scan.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_018_Irrad_500V.dat |
Telescope run |
650 |
Triggers |
200000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.2 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
33
|
Thu Apr 13 20:49:30 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_IFX_CB_110V.dat | 017 | 175000 | 109, 4.5, 240 | No | Unknown |
Remarks: Telescope run 532. Bias scan 110 V.
Parameter |
Value |
Alibava run |
run_017_IFX_CB_110V.dat |
Telescope run |
532 |
Triggers |
175000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-110 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
93
|
Mon Apr 17 09:01:09 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Baby_80V.dat | 017 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 594. Bias scan 80 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_017_Baby_80V.dat |
Telescope run |
594 |
Triggers |
112000 |
Alibava trigger eff. |
~90% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-80 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
144
|
Fri Apr 21 07:46:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Irrad_500V.dat | 017 | 200000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 649. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Beam energy scan.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_017_Irrad_500V.dat |
Telescope run |
649 |
Triggers |
200000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.4 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
32
|
Thu Apr 13 18:26:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_IFX_CB_100V.dat | 016 | 750000 | 109, 4.5, 240 | No | Crap |
3Remarks: Telescope run 527-531. Bias scan 100 V. Telescope got out of sync. Match with telescope data only up to 175000 events.
Parameter |
Value |
Alibava run |
run_016_IFX_CB_100V.dat |
Telescope run |
527-531 |
Triggers |
750000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
92
|
Mon Apr 17 08:14:24 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Baby_75V.dat | 016 | 112000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 593. Bias scan 75 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_016_Baby_75V.dat |
Telescope run |
593 |
Triggers |
112000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-75 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
143
|
Thu Apr 20 22:19:21 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Irrad_500V.dat | 016 | 2500000 | 96, 64, 370 | No | Unknown |
Remarks: Telescope run 648. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
rotation scan.
Telescope chiller turned on (15 deg).
Run finished over night!
Parameter |
Value |
Alibava run |
run_016_Irrad_500V.dat |
Telescope run |
648 |
Triggers |
2500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
370 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
28
|
Thu Apr 13 17:47:28 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_IFX_CB_90V.dat | 015 | 175000 | 109, 4.5, 240 | No | Unknown |
3Remarks: Telescope run 526. Bias scan 90 V.
Parameter |
Value |
Alibava run |
run_015_IFX_CB_90V.dat |
Telescope run |
526 |
Triggers |
175000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-90 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
90
|
Sun Apr 16 21:43:15 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Baby_100V.dat | 015 | 2500000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_015_Baby_100V.dat |
Telescope run |
592 |
Triggers |
2500000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
141
|
Thu Apr 20 20:15:12 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Irrad_500V.dat | 015 | 300000 | 96, 64, 350 | No | Unknown |
Remarks: Telescope run 647. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
rotation scan.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_015_Irrad_500V.dat |
Telescope run |
647 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
350 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
25
|
Thu Apr 13 17:11:31 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_IFX_CB_80V.dat | 014 | 175000 | 109, 4.5, 240 | No | Unknown |
3Remarks: Telescope run 525. Bias scan 80 V.
Parameter |
Value |
Alibava run |
run_014_IFX_CB_80V.dat |
Telescope run |
525 |
Triggers |
175000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-80 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
88
|
Sun Apr 16 20:22:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Baby_70V.dat | 014 | 250000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 591. Bias scan 70 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_014_Baby_70V.dat |
Telescope run |
591 |
Triggers |
250000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-70 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
142
|
Thu Apr 20 21:25:21 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Irrad_500V.dat | 014 | 300000 | 96, 69, 360 | No | Unknown |
Remarks: Telescope run 646. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Positoj scan vertical.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_014_Irrad_500V.dat |
Telescope run |
646 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
69 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|