ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
Text |
|
95
|
Mon Apr 17 09:29:40 2017 |
Axel Koenig | ALiBaVa (IFX) | run_018_Baby_90V.dat | 018 | 112000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 595. Bias scan 90
V.
Telescope chiller turned off (could |
|
144
|
Fri Apr 21 07:46:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Irrad_500V.dat | 017 | 200000 | 96, 64, 360 | No | Unknown | Remarks: Telescope run 649. Bias voltage
-500V, central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
33
|
Thu Apr 13 20:49:30 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_IFX_CB_110V.dat | 017 | 175000 | 109, 4.5, 240 | No | Unknown | Remarks: Telescope run 532. Bias scan 110
V.
|
|
93
|
Mon Apr 17 09:01:09 2017 |
Axel Koenig | ALiBaVa (IFX) | run_017_Baby_80V.dat | 017 | 112000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 594. Bias scan 80
V.
Telescope chiller turned off (could |
|
143
|
Thu Apr 20 22:19:21 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Irrad_500V.dat | 016 | 2500000 | 96, 64, 370 | No | Unknown | Remarks: Telescope run 648. Bias voltage
-500V, central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
32
|
Thu Apr 13 18:26:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_IFX_CB_100V.dat | 016 | 750000 | 109, 4.5, 240 | No | Crap | 3Remarks: Telescope run 527-531. Bias scan
100 V. Telescope got out of sync. Match with
telescope data only up to 175000 events. |
|
92
|
Mon Apr 17 08:14:24 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Baby_75V.dat | 016 | 112000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 593. Bias scan 75
V.
Telescope chiller turned off (could |
|
141
|
Thu Apr 20 20:15:12 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Irrad_500V.dat | 015 | 300000 | 96, 64, 350 | No | Unknown | Remarks: Telescope run 647. Bias voltage
-500V, central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
28
|
Thu Apr 13 17:47:28 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_IFX_CB_90V.dat | 015 | 175000 | 109, 4.5, 240 | No | Unknown | 3Remarks: Telescope run 526. Bias scan
90 V.
|
|
90
|
Sun Apr 16 21:43:15 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Baby_100V.dat | 015 | 2500000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 592. Long run, bias
voltage 100 V. Long run finished without
any problems. |
|
142
|
Thu Apr 20 21:25:21 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Irrad_500V.dat | 014 | 300000 | 96, 69, 360 | No | Unknown | Remarks: Telescope run 646. Bias voltage
-500V, central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
25
|
Thu Apr 13 17:11:31 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_IFX_CB_80V.dat | 014 | 175000 | 109, 4.5, 240 | No | Unknown | 3Remarks: Telescope run 525. Bias scan
80 V.
|
|
88
|
Sun Apr 16 20:22:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Baby_70V.dat | 014 | 250000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 591. Bias scan 70
V.
Telescope chiller turned off (could |
|
140
|
Thu Apr 20 16:05:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_013_Irrad_500V.dat | 013 | 750000 | 96, 54, 360 | No | Unknown | Remarks: Telescope run 643. Bias voltage
-500V, central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
21
|
Thu Apr 13 16:33:32 2017 |
Axel Koenig | ALiBaVa (IFX) | run_013_IFX_CB_75V.dat | 013 | 175000 | 109, 4.5, 240 | No | Unknown | Remarks: Telescope run 524. Bias scan 75
V.
|
|
87
|
Sun Apr 16 19:46:01 2017 |
Axel Koenig | ALiBaVa (IFX) | run_013_Baby_65V.dat | 013 | 112000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 590. Bias scan 65
V.
Telescope chiller turned off (could |
|
139
|
Thu Apr 20 15:08:33 2017 |
Axel Koenig | ALiBaVa (IFX) | run_012_Irrad_250V.dat | 012 | 300000 | 96, 64, 360 | No | Unknown | Remarks: Telescope run 642. Bias scan -250V,
central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
18
|
Thu Apr 13 16:00:25 2017 |
Axel Koenig | ALiBaVa (IFX) | run_012_IFX_CB_70V.dat | 012 | 175000 | 109, 4.5, 240 | No | Unknown | Remarks: Telescope run 523. Bias scan 70
V.
|
|
86
|
Sun Apr 16 19:04:41 2017 |
Axel Koenig | ALiBaVa (IFX) | run_012_Baby_60V.dat | 012 | 135000 | 102.5, 22.5, 240 | No | Unknown | Remarks: Telescope run 589. Bias scan 60
V.
Telescope chiller turned off (could |
|
138
|
Thu Apr 20 14:09:44 2017 |
Axel Koenig | ALiBaVa (IFX) | run_011_Irrad_350V.dat | 011 | 300000 | 96, 64, 360 | No | Unknown | Remarks: Telescope run 641. Bias scan -350V,
central position of sensor (DUT parallel
to telescope planes at 360 deg due to different |
|
|