Tue May 19 10:57:19 2015, Hao Yin, Belle II, system, FIR, FIR filter
|
first fir filter run:
# 1:[0x[FADC ID] in hex], 2:[APV25 ChannelNr], 3-10:[fir coef in float]
0x1,0,1.13520608876,-0.0660414994664,-0.0344046528212,-0.0160940592489,-0.0188049576486,-0.00405635272718,0.0022422085805,0.0019532245698 |
Mon Nov 30 17:11:17 2015, Hao Yin, Belle II, module, FIRRun001, FIRRun001 aft ADC_HOT
|
FirRun 20 min after I2C |
Mon Nov 30 15:12:19 2015, Hao Yin, , , , FIR_ADC config
|
FIR filter and ADC delay test:
ADC delay and FIR filter with and without cooling to reproduce error detected during CERN beam test 2015.
|
Tue May 19 14:48:06 2015, Hao Yin, Belle II, module, L6 Noise inJection Runs, L6 Noise inJection Runs
|
Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V. ground and their combination |
Tue May 19 13:42:04 2015, Hao Yin, , , , L6 Noise inJection Setup
|
Test Nr. 1:
RLC between DockBox and Hybrid (both side).
Preliminary Test on L6, but all other sensors are connected. |
Wed May 20 10:12:12 2015, Hao Yin, , , , Ladder RLC test (CMC Injection)
|
L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder only, noise injection on one hybrid (injection point = cable between hybrid and junction board, see attachment |
Wed May 7 14:36:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left) |
Thu May 8 16:51:03 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left) |
Wed May 7 15:04:32 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center) |
Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single)
|
Failed with Error: "***ERROR*** Init NECO failed, Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source |
Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center) |
Wed May 7 15:53:38 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right) |
Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center) |
Wed May 7 16:43:37 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left) |
Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left) |
Wed May 7 17:33:21 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center) |
Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center) |
Wed May 7 18:20:36 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (multi6) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right) |
Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
|
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right) |
Thu May 21 18:23:22 2015, Hao Yin, , , , Noise Injection LV cable
|
(TestNr. 15)
injecting sin wave into LV at different frequencies to analyse the output frequency and noise ground level after the junction borad. |
|