Entry  Tue Apr 22 19:34:09 2008, Markus Friedl, SPS Testbeam June08, module, hybrid 01, Properties of hybrid 01, sensor fully bonded, HV=100V 6x
HV bias glued to backplane, HV=100V
Entry  Tue May 19 11:01:29 2015, Hao Yin, Belle II, system, Pedestal, PedestalRun 16x
FIRRun001

Baseline measurement without injections, 50000 event,

room temperature.
Entry  Fri Apr 18 17:23:26 2008, Markus Friedl, SPS Testbeam June08, hybrid, hybrid 01, Noise of hybrid 01, sensor fully bonded, no HV hybrid01_sen_nohv_pednoise_apv0.pnghybrid01_sen_nohv_pednoise_apv1.png
HV bias not yet glued to backplane
Entry  Tue May 19 09:31:50 2015, Hao Yin, , , , Noise Test ITA 
Everything works except L3 p-side.

The config file is shown in the following:

### Original Configuration File Name: /home/katsuro/tuxdaq_devel/config/delay_scan.latency_scan.cfg ###
Entry  Thu May 21 18:23:22 2015, Hao Yin, , , , Noise Injection LV cable P1000717.JPG
(TestNr. 15)

injecting sin wave into LV at different frequencies to analyse the output frequency and noise ground level after the junction borad.
Entry  Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
Entry  Wed May 7 18:20:36 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
Entry  Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
Entry  Wed May 7 17:33:21 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
Entry  Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
Entry  Wed May 7 16:43:37 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
Entry  Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
Entry  Wed May 7 15:53:38 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right)
Entry  Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 
Failed with Error: "***ERROR*** Init NECO failed,  Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source
Entry  Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
Entry  Wed May 7 15:04:32 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center)
Entry  Thu May 8 16:51:03 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
Entry  Wed May 7 14:36:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left)
Entry  Wed May 20 10:12:12 2015, Hao Yin, , , , Ladder RLC test (CMC Injection) 
L5 Ladder Test

folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test

Setup: ladder only, noise injection on one hybrid (injection point = cable between hybrid and junction board, see attachment
Entry  Tue May 19 13:42:04 2015, Hao Yin, , , , L6 Noise inJection Setup P1000702.JPGP1000700.JPGP1000699.JPGP1000703.JPGP1000707.JPG
Test Nr. 1:

RLC between DockBox and Hybrid (both side).

Preliminary Test on L6, but all other sensors are connected.