  102   Sat Jun 13 13:01:39 2015 Hao YinBelle II FADC (H6A)Hardware029 3NoGood

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

L3 rotated.
taget: CE, pos 3
 

  103   Sat Jun 13 16:47:28 2015 Benedikt WürknerSVD3 (H6B)Mimosa threshold with FEI48212000 NoGood

Set mimosa threshold to 5 and recorded with FEI4 upstream

L3 already in sensor but not yet configured. 

Probably to noisy to help much

  104   Sat Jun 13 17:05:35 2015 Benedikt WürknerSVD3 (H6B)L3 with FEI484300001NoGood

L3 sensor at position x: 105, y: 47 hitting apvs: 2&3 on p-side and apv 3 on n-side

Attachment 1: Telescope_with_L3.png
Telescope_with_L3.png
  105   Sat Jun 13 18:02:04 2015 Benedikt WürknerSVD3 (H6B)L3 with FEI485700002NoGood

L3 sensor at position x: 115, y: 47 hitting apvs: 2&3 on p-side and apv 3&4 on n-side

  106   Sat Jun 13 19:14:41 2015 Benedikt WürknerSVD3 (H6B)L3 with FEI4867320003NoGood

L3 sensor at position x: 115, y: 57 hitting apvs: 1&2 on p-side and apv 3&4 on n-side

  107   Sat Jun 13 19:26:26 2015 Hao YinBelle II FADC (H6A)Hardware030 3NoGood

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

wo L3 and L4
taget: CE, pos 3
 

  108   Sat Jun 13 19:29:50 2015 Hao YinBelle II FADC (H6A)Hardware030 1NoGood

room temp

FIRRun002,
PedestalRun012,
CalibrationRun003

wo L3 and L4
taget: bw, pos 1
 

  1   Tue May 12 10:27:39 2015 Benedikt WürknerSVD3 (H6B)Setup information    Unknown

Information concerning the SVD3 setup during a beam test

In the beam area setup the whole crate and the power supply with the usual spider cable and the two Keithly 2410 high voltage supplies. Monitoring of the 2410 happens via a NI MAX interface that connects to the GPIB-Ethernet interface and needs to be configured there. The IP and password are noted on the device. The software can be found on heros in medialib/LONGTERM/longterm R3.1_doubleSided as a normal *.vi file. 

Default adresses 16 and 17 as defined in labview, need to figure out on site which is which, if the voltage selected (e.g. 100V) is applied as +50/-50 or if it is applied as +100/-100 before connecting the cables. 

Take a run without dut as well to check the telescope integrity. Without dut in beamline!!!!!

Attachment 1: spider-config.jpg
spider-config.jpg
  2   Wed Jun 3 10:48:42 2015 Benedikt WürknercommonNetworking    Unknown

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.174.109 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Benni mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.124 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 SVD3 DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22), VNC(5900)  SSH(9004), VNC(9012)
192.168.0.20 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.19 Cooling control PC VNC(5900) VNC(9011)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
137.138.113.254 Aida PC   vnc(5900)

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

  3   Wed Jun 3 17:23:07 2015 Thomas BergauerBelle II FADC (H6A)XY stage positions    Unknown

x-Achse: positiv Richtung Saleve (counting room)

y-Achse: positiv Richtung UNTEN!!

 

position of laddertestbox xy stages:

Rev. Pos (BWD Sensor, BWD, Oben) x= 82.3, y=110.6

Mitte Sensor:

Pos 1: (mitte BWD sensor): x=144.74, y=80.8

Pos 2: (mitte Origami -z): x=269.62, y=80.8

Pos 3: (mitte Origami ce): x=394.42, y=80.8

Pos 4 (mitte FWD Micron Sensor): x=517, y=80.8

Ecke:

Pos 5 (Ecke BWD sensor): x=92.3, y=105.6

Pos 6 (Ecke Origami -z): x=217.18, y=105.6

Pos 7 (Ecke Origami ce): x=342.06, y=105.6

Pos 8 (Ecke FWD sensor): x=467,62, y=56,3 

Pos 9 (Ecke FWD sensor): x=568,33 y=64,48

Attachment 1: L5_Class_B-.PNG
L5_Class_B-.PNG
  4   Thu Jun 4 14:15:50 2015 Hao YinBelle II FADC (H6A)FIR001   Good

FIR filer and ADC delay with all sensor and telescope.
telescope n-side switched.

  5   Thu Jun 4 14:16:20 2015 Hao YinBelle II FADC (H6A)Pedestal00110000  Good

FirRun001, room temp
telescope n-side switched.

  8   Thu Jun 4 18:45:42 2015 Hao YinBelle II FADC (H6A)Pedestal00310000  Good

firrun003, room temp
 

  9   Thu Jun 4 18:49:03 2015 Benedikt WürknerSVD3 (H6B)Setup    Unknown
Attachment 1: IMG_20150604_184442.jpg
IMG_20150604_184442.jpg
Attachment 2: IMG_20150604_184451.jpg
IMG_20150604_184451.jpg
Attachment 3: IMG_20150604_184516.jpg
IMG_20150604_184516.jpg
  12   Fri Jun 5 12:02:29 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration001   Good

room temp max subevent at 2. with lat = 96

  13   Fri Jun 5 12:03:34 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration002   Good

lat = 97 to a greater range of lat scan

  14   Fri Jun 5 19:55:00 2015 Hao YinBelle II FADC (H6A)Sixlet Calibration003   Unknown

lat = 98

room temp

pedestalrun 003

  15   Fri Jun 5 19:59:44 2015 Hao YinBelle II FADC (H6A)Pedestal00410000  Good

update pedestal values for room temp sixlet runs.
 

  16   Fri Jun 5 23:38:51 2015 Hao YinBelle II FADC (H6A)Pedestal00510000  Unknown

Readjust after cooling box.

room temp, firrun002
 

  20   Sat Jun 6 16:14:36 2015 Benedikt WürknerSVD3 (H6B)calibration run and setup informationcal01   Unknown

Calibration Run with +- 50V Bias with higher compliance since the p-side draws more current than expected (23muA by the MAMBO)

 