Tue May 12 10:27:39 2015, Benedikt Würkner, SVD3 (H6B), Setup information, , , , , Unknown
|
Information concerning the SVD3 setup during a beam test
In the beam area setup the whole crate and the power supply with the usual spider cable and the two Keithly 2410 high voltage supplies.
Monitoring of the 2410 happens via a NI MAX interface that connects to the GPIB-Ethernet interface and needs to be configured there. The IP and password |
Wed Jun 3 10:48:42 2015, Benedikt Würkner, common, Networking, , , , , Unknown
|
WLAN Router:
SSID: Hephy
password: 20supersecret14
DHCP Range: 192.168.0.200 to 239 |
Wed Jun 3 17:23:07 2015, Thomas Bergauer, Belle II FADC (H6A), XY stage positions, , , , , Unknown
|
x-Achse: positiv Richtung Saleve (counting room)
y-Achse: positiv Richtung UNTEN!! |
Thu Jun 4 14:15:50 2015, Hao Yin, Belle II FADC (H6A), FIR, 001, , , , Good
|
FIR filer and ADC delay with all sensor and telescope.
telescope n-side switched. |
Thu Jun 4 14:16:20 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 001, 10000, , , Good
|
FirRun001, room temp
telescope n-side switched. |
Thu Jun 4 18:45:42 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 003, 10000, , , Good
|
firrun003, room temp
|
Thu Jun 4 18:49:03 2015, Benedikt Würkner, SVD3 (H6B), Setup, , , , , Unknown
|
|
Fri Jun 5 12:02:29 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 001, , , , Good
|
room temp max subevent at 2. with lat = 96 |
Fri Jun 5 12:03:34 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 002, , , , Good
|
lat = 97 to a greater range of lat scan |
Fri Jun 5 19:55:00 2015, Hao Yin, Belle II FADC (H6A), Sixlet Calibration, 003, , , , Unknown
|
lat = 98
room temp
pedestalrun 003 |
Fri Jun 5 19:59:44 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 004, 10000, , , Good
|
update pedestal values for room temp sixlet runs.
|
Fri Jun 5 23:38:51 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 005, 10000, , , Unknown
|
Readjust after cooling box.
room temp, firrun002
|
Sat Jun 6 16:14:36 2015, Benedikt Würkner, SVD3 (H6B), calibration run and setup information, cal01, , , , Unknown
|
Calibration Run with +- 50V Bias with higher compliance since the p-side draws more current than expected (23muA by the MAMBO)
|
Sat Jun 6 16:17:52 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw002, 5000, , , Good
|
Table: 100:70
Bias: +-50V
Run to confirm trigger delay |
Sat Jun 6 16:18:48 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw003, 50000, , , Unknown
|
Table: 100:70
Bias: +-50V
Run to confirm trigger delay |
Sat Jun 6 21:00:15 2015, Benedikt Würkner, SVD3 (H6B), first hardware run with TLU and Telescope, hw004, 117171, , , Unknown
|
Table: 100:70
Bias: +-50V
600 pedestal |
Sat Jun 6 23:30:29 2015, Benedikt Würkner, Belle II FADC (H6A), Hardware, 009, , , , Good
|
room temp, FIRRun002, PedestalRun005, room temp
target: FW, pos 9 (p-0, n-128*4) |
Sun Jun 7 00:58:33 2015, Benedikt Würkner, SVD3 (H6B), hardware run, hw006, , , , Crap
|
Table: 100:70
Bias: +-50V
600 pedestal |
Sun Jun 7 10:36:38 2015, Hao Yin, Belle II FADC (H6A), Pedestal, 006, 10000, , , Unknown
|
Cooled, Temp see attachment
FirRun002
|
Sun Jun 7 10:39:56 2015, Hao Yin, Belle II FADC (H6A), Calibration, 002, , , , Good
|
Cooled!
FIRRun002, pedestalrun006; temp see attachment in pedestalrun006
|
|