ID Date Author Project Subjectup Run Number Events XYPosition Cooling Data
  70   Tue Jun 9 16:22:59 2015 Benedikt WürknerSVD3 (H6B)Beam Profile Results66 und 67 2NoGood
  28   Sun Jun 7 10:39:56 2015 Hao YinBelle II FADC (H6A)Calibration002   Good

Cooled!
FIRRun002, pedestalrun006; temp see attachment in pedestalrun006
 

  63   Tue Jun 9 09:33:33 2015 Hao YinBelle II FADC (H6A)Calibration003   Good

room temp
FIRRun002,
pedestalrun006;
pedestalrun007
 

  39   Sun Jun 7 20:02:40 2015 Hao YinBelle II FADC (H6A)Cooling Box Emergency break    Unknown

Something triggered a emergency break. HWRun012 only last 1-10k event has to be discarded.

  56   Mon Jun 8 16:53:13 2015 Benedikt WürknerSVD3 (H6B)EUTelescope Fitter not working investigation    Unknown

Apparently every problem can be attributed to a misalignment problem. The telescope has troubles with heavily misaligned DUTs. Was resolved by creating different gear-files for each run with pretty precise coordinates of the DUT position calculated for the telescope coordinate system. 

Additionally one has to watch out for misaligned planes of the telescope itself. It was required to allow for more than 2mm offset for the telescope planes behind the DUTs. This can be easily checked by looking at the PreAligner plots in the -hitmaker-histo.root file.

It look something like this:

and not like this:

 

Run number offset value Comment
49 -1  
50 -1 Expected default value. EORE=49401
51 -1 Expected default value. EORE=49400
52 -1 Checked -1 EORE= 49401
53 -1 Checked -1 EORE= 49401
54 -1 Checked -1 EORE= 119401, 
55 -1 Checked -1 EORE= 409388
56 -1 Checked -1 EORE= 49392
57 -1 Checked -1 EORE= 49377
58 -1 Checked -1 EORE= 49397

 

Run Position x-Table x-telescope FW x-telescope BW
49 1 100 -13,7 -16,7
50 2 69,3 17 14
51 3 38,6 47,7 44,7
52 4 130,7 -44,4 -47,4
53 5 30,5 55,8 52,8
54 6 136,8 -50,5 -53,5
55 7 30,5 55,8 52,8
56 8 136,8 -50,5 -53,5
57 9 30,5 55,8 52,8
58 10 136,8 -50,5 -53,5
  80   Wed Jun 10 18:05:03 2015 Benedikt WürknerSVD3 (H6B)FEI4 configuration   NoUnknown

There are two planes, one fixed upstream and one fixed downstream. 

CIS3WII_6 upstream and CIS2WI_IBL2 downstream.

They are configured using the pc in H6B which can be accessed via microsoft remote desktop from the network 192.168.5.x using the ip 192.168.5.6. 

The configuration files can be found in the folder "E:\ConfigurationCMS\" on the server and are named after the modules. 

Only one of the FEI4 detectors can be used at a time since they are of different generations (FEI4A and FEI4B) which can't be used at the same time with the available USB board. vnc

The configuration for EUDAQ needs to be adapted for the used module by changing the name of the configuration file. 

[Producer.USBpixI4]
SRAM_READOUT_AT = 5
SkipConfiguration = no
UseSingleBoardConfig = no
boards = 230
modules[230] = 1
#upstream
config_file = E:\ConfigurationCMS\CIS3_W11_06_thr1600_7to21ke_modified.cfg.root
#downstream:
#config_file = E:\ConfigurationCMS\CIS2_W02_IBL1_thr1600_7to14_modified.cfg.root
fpga_firmware = E:\icwiki_svn\USBPixI4\host\tags\release-5.3\config\usbpixi4.bit
lvl1_delay = 16
tlu_trigger_data_delay = 10

In my experience switching between the planes also requires a restart of the USBPix DAQ because apparently something is not working with the reload of a different config file afterwards. I had the phenomenon that the DAQ responded like it was working but the datastream was empty. Therefore always check the online monitor for hitmaps. 

  4   Thu Jun 4 14:15:50 2015 Hao YinBelle II FADC (H6A)FIR001   Good

FIR filer and ADC delay with all sensor and telescope.
telescope n-side switched.

  72   Tue Jun 9 20:30:37 2015 Hao YinBelle II FADC (H6A)FIR004   Good

FIR filer and ADC delay with all sensor and telescope.
Telescope alignment

  94   Fri Jun 12 09:31:58 2015 Hao YinBelle II FADC (H6A)FIR005  YesGood

FIR filer and ADC delay for long sixlet cal run.

  6   Thu Jun 4 15:12:41 2015 Hao YinBelle II FADC (H6A)Hardware001500001NoGood

PedestalRun001, FIRRun001, room temp
telescope n-side switched.
In order to correct the position change the

  7   Thu Jun 4 18:44:50 2015 Hao YinBelle II FADC (H6A)Hardware002500002NoGood

room temp, FIRRun001, pedestal run 003

  10   Thu Jun 4 22:07:16 2015 Hao YinBelle II FADC (H6A)Hardware003189k3NoGood

CE. pedestal run 003. Fir run 002. Room temp

  11   Fri Jun 5 08:20:27 2015 Hao YinBelle II FADC (H6A)Hardware004500004NoGood

room temp, FIRRun002, pedestalrun003, taget FW

  17   Fri Jun 5 23:39:49 2015 Hao YinBelle II FADC (H6A)Hardware005~200k5NoGood

FIRRun002, pedestalrun005, room temp
Target BW: beam spot at ~ (0 p, 0 n)

  18   Sat Jun 6 12:43:55 2015 Hao YinBelle II FADC (H6A)Hardware006500006NoGood

FIRRun002, room temp, pedestalrun005,
layout: same as HW 005
target: -z, pos 6 (strip: p-0, n-0);

NOTE: results shown in the attachments has been evaluated with cmc containing 128 strip
 

  23   Sat Jun 6 16:48:41 2015 Hao YinBelle II FADC (H6A)Hardware008500008NoGood

room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 8 (p-0, n-0)

  25   Sat Jun 6 23:30:29 2015 Benedikt WürknerBelle II FADC (H6A)Hardware009   Good

room temp, FIRRun002, PedestalRun005, room temp

target: FW, pos 9 (p-0, n-128*4)

  34   Sun Jun 7 13:19:19 2015 Hao YinBelle II FADC (H6A)Hardware010   Good

cooled

FIRRun002, PedestalRun006 (temp enty)

target: BW, pos 1

  35   Sun Jun 7 13:21:15 2015 Hao YinBelle II FADC (H6A)Hardware01150000  Good

cooled (see attachment)

FIRRun002, PedestalRun006

target: -Z, pos 2

  38   Sun Jun 7 15:59:05 2015 Hao YinBelle II FADC (H6A)Hardware01250000  Unknown

cooled (see attachment)

FIRRun002, PedestalRun006

target: CE, pos 2

cooling box emergency break ... ie about the last 1-10 k not useable.